Shopping Cart

No products in the cart.

BS EN 60839-11-32:2017

$215.11

Alarm and electronic security systems – Electronic access control systems. Access control monitoring based on Web services

Published By Publication Date Number of Pages
BSI 2017 80
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of IEC 60839 defines the Web services interface for electronic access control systems. This includes listing electronic access control system components, their logical composition, monitoring their states and controlling them. It also includes a mapping of mandatory and optional requirements as per IEC 60839‑11‑1 .

This document applies to physical security only. Physical security prevents unauthorized personnel, attackers or accidental intruders from physically accessing a building, room, etc.

Web services usage and device management functionality are outside of the scope of this document. Refer to IEC 60839‑11‑31 for more information.

This document does not in any way limit a manufacturer to add other protocols or extend the protocol defined here. For rules on how to accomplish this refer to IEC 60839‑11‑31 .

PDF Catalog

PDF Pages PDF Title
6 English
CONTENTS
9 FOREWORD
11 INTRODUCTION
12 1 Scope
2 Normative references
3 Terms, definitions and abbreviated terms
3.1 Terms and definitions
14 3.2 Abbreviated terms
4 Overview
4.1 Interoperability
4.2 Event handling
4.3 Architecture
15 4.4 External authorization (Overriding)
4.5 Security considerations
Figure 1 – Schematic overview of an access controlled door
16 4.6 Door (access point) control
4.7 Design considerations
4.7.1 Instance-level capabilities
4.7.2 Retrieving status
4.7.3 Retrieving system configuration
17 5 Access control
5.1 General
5.2 Service capabilities
5.2.1 General
5.2.2 Data structures: ServiceCapabilities
5.2.3 GetServiceCapabilities command
18 5.3 Access point (portal side) information
5.3.1 Data structures
Tables
Table 1 – GetServiceCapabilities command
19 5.3.2 GetAccessPointInfoList command
20 5.3.3 GetAccessPointInfo command
Table 2 – GetAccessPointInfoList command
Table 3 – GetAccessPointInfo command
21 5.4 Area information
5.4.1 Data structures: AreaInfo
5.4.2 GetAreaInfoList command
5.4.3 GetAreaInfo command
Table 4 – GetAreaInfoList command
22 5.5 Access point (portal side) status
5.5.1 General
5.5.2 Data structures: AccessPointState
5.5.3 GetAccessPointState command
Table 5 – GetAreaInfo command
23 5.6 Access control commands
5.6.1 General
5.6.2 Data structures: Decision enumeration
5.6.3 EnableAccessPoint command
Table 6 – GetAccessPointState command
Table 7 – EnableAccessPoint command
24 5.6.4 DisableAccessPoint command
5.6.5 ExternalAuthorization command
Table 8 – DisableAccessPoint command
Table 9 – ExternalAuthorization command
25 5.7 Notification topics
5.7.1 Event overview
5.7.2 General transaction event layout
26 5.7.3 Access granted
27 5.7.4 Access taken
5.7.5 Access not taken
28 5.7.6 Access denied
30 5.7.7 Duress
5.7.8 External authorization (Override)
32 5.7.9 Status changes
5.7.10 Configuration changes
33 6 Door (access point) control
6.1 General
6.2 Service capabilities
6.2.1 General
6.2.2 Data structures: ServiceCapabilities
6.2.3 GetServiceCapabilities command
34 6.3 Door (access point) information
6.3.1 Data structures
Table 10 – GetServiceCapabilities command
35 6.3.2 GetDoorInfoList command
36 6.3.3 GetDoorInfo command
Table 11 – GetDoorInfoList command
Table 12 – GetDoorInfo command
37 6.4 Door (access point) status
6.4.1 General
6.4.2 Data structures
39 6.4.3 GetDoorState command
40 6.5 Door (access point) control commands
6.5.1 General
6.5.2 AccessDoor command
Table 13 – GetDoorState command
41 6.5.3 LockDoor command
Table 14 – AccessDoor command
Table 15 – LockDoor command
42 6.5.4 UnlockDoor command
6.5.5 BlockDoor command
Table 16 – UnlockDoor command
Table 17 – BlockDoor command
43 6.5.6 LockDownDoor command
6.5.7 LockDownReleaseDoor command
Table 18 – LockDownDoor command
44 6.5.8 LockOpenDoor command
6.5.9 LockOpenReleaseDoor command
Table 19 – LockDownReleaseDoor command
Table 20 – LockOpenDoor command
45 6.5.10 DoubleLockDoor command
Table 21 – LockOpenReleaseDoor command
Table 22 – DoubleLockDoor command
46 6.6 Notification Topics
6.6.1 General
6.6.2 Status changes
47 6.6.3 Configuration changes
49 Annex A (normative)Access control interface XML schemata
A.1 Access control service WSDL
56 A.2 Door control service WSDL
66 A.3 Common schema
68 Annex B (informative)Mapping of mandatory functions in IEC 60839-11-1
Table B.1 – Access point interface requirements
69 Table B.2 – Indication and annunciation requirements
73 Table B.3 – Recognition requirements
75 Table B.4 – Duress signalling requirements
Table B.5 – Overriding requirements
76 Table B.6 – System self protection requirements
77 Bibliography
BS EN 60839-11-32:2017
$215.11