BS EN 60855-1:2017
$167.15
Live working. Insulating foam-filled tubes and solid rods – Tubes and rods of a circular cross-section
Published By | Publication Date | Number of Pages |
BSI | 2017 | 38 |
This part of IEC 60855 is applicable to insulating-filled tubes and solid rods, of a circular cross-section, made of synthetic materials with reinforced fibreglass and intended to be used in the manufacture and construction of tools, devices and equipment for carrying out live working on electrical systems operating at voltages above 1 kV.
Foam-filled tubes and solid rods of cross-section other than circular and/or made with material other than synthetic materials with reinforced fibreglass are not covered by this part of IEC 60855 .
PDF Catalog
PDF Pages | PDF Title |
---|---|
6 | English CONTENTS |
8 | FOREWORD |
10 | INTRODUCTION |
11 | 1 Scope 2 Normative references 3 Terms and definitions |
12 | 4 Requirements 4.1 Materials and design 4.2 Electrical requirements 4.3 Mechanical requirements 4.4 Diameters of foam-filled tubes and solid rods Tables Table 1 – Specified diameters |
13 | 4.5 Marking 4.6 Packaging 5 Tests 5.1 General 5.2 Type test conditions 5.2.1 General |
14 | 5.2.2 Groups and test pieces 5.3 Visual and dimensional checks 5.3.1 General 5.3.2 Visual check |
15 | 5.3.3 Dimensional check 5.4 Electrical tests 5.4.1 General 5.4.2 Dielectric test before and after exposure to humidity |
16 | Figures Figure 1 – Typical dielectric test arrangement |
17 | Figure 2 – Assembly set-up of the test piece to the guard electrodes |
19 | Figure 3 – Constructional drawings for guard electrodes and parts |
21 | Figure 4 – Drawings for guard electrode parts according to test piece diameters |
22 | Table 2 – Maximum current I1 before exposure to humidity |
23 | Figure 5 – Alternative dielectric test under dry condition – Example of a typical test arrangement |
24 | 5.4.3 Wet test |
25 | Figure 6 – Wet test |
26 | 5.5 Mechanical tests 5.5.1 Bending test |
27 | Figure 7 – Bending test |
28 | 5.5.2 Torsion test Table 3 – Values of Fd, f and Fr for bending test |
29 | Figure 8 – Torsion test – Examples for fixing foam-filled tube and solid rod |
30 | 5.5.3 Crushing test on insulating foam-filled tube Table 4 – Values of Cd, ad and Cr for torsion test Table 5 – Values of Fd and Fr for crushing test |
31 | 5.5.4 Electrical test after mechanical ageing Figure 9 – Crushing test |
32 | 5.5.5 Dye penetration test 5.5.6 Durability of marking 6 Conformity assessment of foam-filled tubes and solid rods having completed the production phase |
33 | 7 Modifications |
34 | Annex A (normative)Plan of carrying out of the type tests Table A.1 – Chronological order of the type tests |
35 | Annex B (normative)Classification of defects and associated requirements and tests Table B.1 – Classification of defects and associated requirements and tests |
36 | Bibliography |