This part of IEC 61169 , which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for RF coaxial connectors with clamp coupling, typically for use in 75 Ω cable networks (type F-Quick).
It describes the interface dimensions with gauging information, electrical and mechanical performance including the mandatory tests selected from IEC 61169‑1:2013 , applicable to all DS relating to type F-Quick connectors.
This specification indicates the recommended performance characteristics to be considered when writing a DS and covers test schedules and inspection requirements.
This interface is typically used for indoor connections, which are easily disconnected and reconnected. The typical application is for F-type coaxial receiver leads or F-type coaxial patch cables. The interface may also be known as a Push-on connector. It is preferred to use the fixed (screwed) connectors type F according to IEC 61169‑24:2009 .
PDF Catalog
PDF Pages | PDF Title |
---|---|
6 | CONTENTS |
8 | FOREWORD |
10 | 1 Scope 2 Normative references 3 Interface dimensions 3.1 Dimensions 3.1.1 Common dimensions |
11 | 3.1.2 Example of connector “F-Quick” type male plug with resilient outer conductor sleeve (indoor) physical dimensions Figures Figure 1 – Connector “F-Quick” type male plug: general dimensions Tables Table 1 – Connector “F” type male plug (indoor) |
12 | 3.1.3 Example of connector “F-Quick” type male plug with slotted outer conductor (indoor) physical dimensions 3.1.4 Example of connector “F-Quick” type male plug with slotted outer conductor and snap ring (indoor) physical dimensions Figure 2 – Example of connector “F-Quick” type male plug with resilient outer conductor sleeve (indoor) Figure 3 – Example of connector “F-Quick” type male plug with slotted outer conductor (indoor) |
13 | 3.2 Mechanical gauges Figure 4 – Example of connector “F-Quick” type male plug with slotted outer conductor and snap ring (indoor) Figure 5 – Mechanical gauge for resilient outer conductor |
14 | 4 Quality assessment procedures 4.1 General 4.2 Ratings and characteristics Table 2 – Ratings and characteristics |
16 | 4.3 Environmental characteristics for outdoor sockets 4.4 Test schedule and inspection requirements 4.4.1 Acceptance tests 4.4.2 Periodic tests Table 3 – Acceptance tests |
17 | Table 4 – Periodic tests |
18 | 4.5 Procedures for the quality conformance 4.5.1 Quality conformance inspection 4.5.2 Quality conformanceand its maintenance – General procedure 5 Instructions for preparation of detail specifications 5.1 General 5.2 Identification of the component |
19 | 5.3 Performance 5.4 Marking, ordering information and related matters 5.5 Selection of tests, test conditions and severities |
20 | 5.6 Blank detail specification pro-forma for type F-QUICK connector |
24 | 6 Marking 6.1 Marking of component 6.2 Marking and contents of package |