BS EN 61347-2-7:2012+A1:2019

$198.66

Lamp controlgear – Particular requirements for battery supplied electronic controlgear for emergency lighting (self-contained)

Published By Publication Date Number of Pages
BSI 2019 54
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of IEC 61347 specifies particular safety requirements for battery supplied electronic controlgear for maintained and non-maintained emergency lighting purposes.

It includes specific requirements for electronic controlgear and control units for self-contained luminaires for emergency lighting as specified by IEC 60598‑2‑22.

It is intended for controlgear for fluorescent lamps, but it is also applicable to other lamp types e.g. incandescent, high pressure discharge lamps and LEDs.

This standard covers the emergency mode operation of a controlgear. For controlgear with a combination of normal and emergency lighting operation, the normal lighting operation aspects are covered by the appropriate part 2 of IEC 61347.

DC supplied electronic controlgear for emergency lighting may or may not include batteries.

This standard does not apply to d.c. supplied electronic controlgear for emergency lighting, which are intended for connection to a centralised emergency power supply system. A centralised emergency power system could be a central battery system.

NOTE Annex J of IEC 61347‑2‑3 applies to a.c., a.c./d.c. or d.c. supplied electronic controlgear for connection to centralised emergency power supply systems that are also intended for emergency lighting operations from a.c./d.c. supplies.

PDF Catalog

PDF Pages PDF Title
2 National foreword
4 European foreword
5 Foreword to amendment A1
Foreword to amendment A1
6 Annex ZA (normative) Normative references to international publications with their corresponding European publications
8 Annex ZZ (informative) Relationship between this European Standard and the safety objectives of Directive 2014/35/EU [2014 OJ L96] aimed to be covered
11 FOREWORD
13 INTRODUCTION
14 INTRODUCTION to Amendment 1
15 1 Scope
2 Normative references
16 3 Terms and definitions
18 4 General requirements
5 General notes on tests
6 Classification
19 7 Marking
7.1 Items to be marked
7.2 Information to be provided
21 8 Protection against accidental contact with live parts
9 Terminals
10 Provisions for protective earthing
11 Moisture resistance and insulation
12 Electric strength
13 Thermal endurance test for windings of controlgear
14 Fault conditions
15 Starting conditions
16 Lamp current
22 17 Supply current
18 Maximum current in any lead (with cathode preheating)
19 Lamp operating current waveforms
20 Functional safety (EBLF , EOFX)
20.1 Requirements for fluorescent lamp controlgear
24 20.2 Requirements for LED lamp controlgear
20.2.1 Constant current LED controlgear: EOFI and Iemergency
25 20.2.2 Constant voltage and constant power LED controlgear
20.3 Requirements for other light source controlgear
21 Changeover operation
26 22 Recharging device
28 23 Protection against excessive discharge
29 24 Indicator
25 Remote control, rest mode, inhibition mode
30 26 Temperature cycling test and endurance test
27 Polarity reversal
28 Fault conditions
31 29 Construction
30 Creepage distances and clearances
31 Screws, current-carrying parts and connections
32 Resistance to heat, fire and tracking
33 Resistance to corrosion
34 Abnormal lamp conditions
36 34.6 Compliance
37 35 Protection of associated components
35.1 Controlgear for fluorescent lamps
35.1.1 Peak voltage limits
35.1.2 Working voltage limits
35.1.3 Compliance
35.2 Controlgear for metal halide lamps
35.3 Controlgear for LED lamps and LED modules
38 Annex A(normative) Test to establish whether a conductive part is a live part, which may cause an electric shock
39 Annex B(normative) Particular requirements for thermally protected lamp controlgear
40 Annex C(normative) Particular requirements for electronic lamp controlgear with means of protection against overheating
41 Annex D(normative) Requirements for carrying out the heating test of thermally protected lamp controlgear
42 Annex E(normative) Use of constant S other than 4 500 in tw tests
43 Annex F(normative) Draught-proof enclosure
44 Annex G(normative) Explanation of the derivation of the values of pulse voltages
45 Annex H(normative) Tests
46 Annex I(normative) Batteries for emergency lighting luminaires
47 Annex J(informative) Rest mode and inhibition mode facilities
48 Annex K(normative) Controlgear incorporating an automatic testing function for emergency lighting operation
51 Annex L(informative) Compatibility between normal mains operation electronic controlgear and battery-powered emergency operation controlgear
54 Bibliography
BS EN 61347-2-7:2012+A1:2019
$198.66