This part of IEC 61853 describes requirements for evaluating PV module performance in terms of power (watts) rating over a range of irradiances and temperatures. IEC 61853-2 describes test procedures for measuring the performance effect of angle of incidence; the estimation of module temperature from irradiance, ambient temperature and wind speed; and impact of spectral response on energy production. IEC 61853-3 describes the calculations of PV module energy (watt-hours) ratings. IEC 61853-4 describes the standard time periods and weather conditions that can be utilized for calculating standardized energy ratings.

The object of this part of IEC 61853 is to define a testing and rating system, which provides the PV module power (watts) at maximum power operation for a set of defined conditions. A second purpose is to provide a full set of characterization parameters for the module under various values of irradiance and temperature. This set of measurements is required in order to perform the module energy rating described in IEC 61853-3.

PDF Catalog

PDF Pages PDF Title
6 English

CONTENTS
7 INTRODUCTION
8 1 Scope and object
2 Normative references
9 3 Sampling
4 Marking
5 Testing and pass criteria
10 6 Report
7 Power rating conditions
7.1 General
11 7.2 STC (Standard Test Conditions)
7.3 NOCT (Nominal Operating Cell Temperature)
7.4 LIC (Low Irradiance Condition)
7.5 HTC (High Temperature Condition)
7.6 LTC (Low Temperature Condition)
8 Procedure for irradiance and temperature performance measurements
8.1 Purpose
Table 1 – Summary of reference power conditions (at AM 1,5)
12 8.2 Simplified procedure for linear modules
Table 2 – Isc, Pmax, Voc and Vmax versus irradiance and temperature
13 8.3 Procedure in natural sunlight with tracker
Figure 1 – Positions for measuring the temperature of the test module behind the cells
15 8.4 Procedure in natural sunlight without tracker
8.5 Procedure with a solar simulator
17 9 Rating of power
9.1 Interpolation of Isc, Voc, Vmax and Pmax
18 9.2 Power rating