BS EN 62444:2013:2014 Edition
$167.15
Cable glands for electrical installations
Published By | Publication Date | Number of Pages |
BSI | 2014 | 34 |
This Standard provides requirements and tests for the construction and performance of cable glands. This standard covers complete cable glands as supplied by the manufacturer or the supplier responsible for placing the product on the market. This standard does not cover cable glands for mineral insulated cables.
This standard covers cable glands with IEC 60423 metric entry threads.
Text deleted
NOTE Certain cable glands may also be used “in Hazardous Areas.” Regard should then be taken of other or additional requirements necessary for the enclosure to be installed in such conditions, for example as specified in the IEC 60079 series.
PDF Catalog
PDF Pages | PDF Title |
---|---|
5 | 1. Scope 2. Normative references |
7 | English CONTENTS |
9 | 1 Scope 2 Normative references 3 Terms and definitions |
10 | 4 General requirements |
11 | 5 General conditions for tests |
12 | 6 Classification 6.1 According to material 6.2 According to mechanical properties Tables Table 1 – Clearance holes for cable glands for test purposes |
13 | 6.3 According to electrical properties 6.4 According to resistance to external influences 6.5 According to sealing system |
14 | 7 Marking and documentation 7.1 Marking 7.2 Durability and legibility 7.3 Documentation |
15 | 8 Construction 9 Mechanical properties 9.1 General |
16 | 9.2 Cable retention test |
17 | Figures Figure 1 – Typical arrangement for cable retention test |
18 | 9.3 Cable anchorage test for non-armoured cable Table 2 – Pull forces for cable retention and cable anchorage |
19 | Figure 2 – Typical arrangement for cable anchorage pull test |
20 | 9.4 Cable anchorage test for armoured cable Figure 3 – Typical arrangement for cable anchorage twist test Table 3 – Torque value for cable anchorage twist test |
21 | Figure 4 – Typical arrangement for cable anchorage test for armoured cable |
22 | 9.5 Resistance to impact |
23 | Table 4 – Impact values |
24 | Figure 5 – Typical arrangement for impact test |
25 | 9.6 Seal performance 10 Electrical properties 10.1 Equipotential bonding to electrical equipment 10.2 Equipotential bonding to metallic layer(s) of cable |
26 | 10.3 Protective connection to earth Table 5 – Electrical current values |
27 | 11 Electromagnetic compatibility Figure 6 – Typical arrangement for electrical current tests |
28 | 12 External influences 12.1 Degree of protection in accordance with IEC 60529 (IP Code) 12.2 Resistance to corrosion 12.3 Resistance to ultraviolet light |
29 | 13 Fire hazard 13.1 Reaction to fire 13.2 Resistance to fire |
30 | Annex A (normative) Particular requirements for cable glands for electrical installations with NPT entry threads Table A.1 – Clearance holes for NPT cable glands for test purposes |
31 | Annex B (informative) Test sequence |
32 | Bibliography |