Shopping Cart

No products in the cart.

BS EN 62625-2:2016

$198.66

Electronic railway equipment. On board driving data recording system – Conformity testing

Published By Publication Date Number of Pages
BSI 2016 62
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of IEC 62625 covers the standardized test methods for verifying the compliance of an On board Driving Data Recording System implementation with the requirements specified by IEC 62625-1.

Furthermore, it covers the conformity testing criteria for designed and manufactured ODDRS. This part of IEC 62625 includes the list of the requirements specified by IEC 62625-1 and the relevant acceptance conditions for ODDRS at design review, type test and routine test phases. For the train level design review and train level test phases, this part provides guidelines for the conformity testing methods to be applied to the ODDRS installed on the train.

This part does not cover the conformity assessment schemes that, according to ISO/IEC Directives Part 2, are the responsibility of ISO policy committee “Committee on conformity assessment” (ISO/CASCO). Consequently, this part does not include elements related to conformity assessment aspects other than design review and testing provisions for the products, processes or services which implements the requirements specified in IEC 62625-1. This part does not delete, change or interpret the general requirements for conformity assessment procedures and vocabulary detailed in ISO/IEC 17000.

PDF Catalog

PDF Pages PDF Title
4 European foreword
Endorsement notice
7 English
CONTENTS
10 FOREWORD
12 INTRODUCTION
13 1 Scope
2 Normative references
3 Terms, definitions, abbreviations, acronyms, and conventions
3.1 Terms and definitions
14 3.2 Abbreviations and acronyms
15 4 Conformity testing
4.1 Overview
4.1.1 General
4.1.2 Applicability
4.1.3 Methodology
16 Figures
Figure 1 – Conformity testing process
18 4.2 Implementation conformity statements
4.2.1 General
4.2.2 FICS and SICS
4.2.3 IXIT
19 5 Functional requirements conformity testing
5.1 Implementation statement for functional requirements conformity testing
5.1.1 General
5.1.2 Record train data
5.1.3 Ensure on board protection of recorded data
Tables
Table 1 – FICS pro-forma “Record train data”
20 5.1.4 Ensure retrieval of recorded data
5.1.5 Recorded data analysis
5.1.6 List of provided optional functions
Table 2 – FICS pro-forma “Ensure on board protection of recorded data”
Table 3 – FICS pro-forma “Ensure retrieval of recorded data”
Table 4 – FICS pro-forma “Recorded data analysis”
Table 5 – FICS pro-forma “List of provided optional functions”
21 5.2 Standardized test methods for functional requirements
22 Table 6 – Standardized test methods for functional requirements
31 6 System requirements conformity testing
6.1 Implementation statement for system requirements conformity testing
6.1.1 General
6.1.2 ODDRS mode
6.1.3 Recording èerformance
6.1.4 Environment
6.1.5 Availability and reliability
Table 7 – SICS pro-forma “ODDRS mode”
Table 8 – SICS pro-forma “Recording performance”
Table 9 – SICS pro-forma “Environment”
32 6.1.6 Security of records
6.1.7 Maintainability and diagnostic
6.1.8 Recorded data survivability
6.1.9 Recording resolution and frequency
Table 10 – SICS pro-forma “Availability and reliability”
Table 11 – SICS pro-forma “Security of records”
Table 12 – SICS pro-forma “Maintainability and diagnostic”
Table 13 – SICS pro-forma “Recorded data survivability”
33 6.1.10 Time of day and date
Table 14 – SICS pro-forma “Recording resolution and frequency”
34 6.1.11 Train location
6.1.12 The unit of train speed
6.1.13 Input requirements
Table 15 – SICS pro-forma “Time of day and date”
Table 16 – SICS pro-forma “Train location”
Table 17 – SICS pro-forma “The unit of train speed”
35 6.1.14 Software identification and upgrading
6.1.15 Replacement time of ODDR unit
6.1.16 Power consumption
6.1.17 Data interface to subsystems and service interface
Table 18 – SICS pro-forma “Input requirements”
Table 19 – SICS pro-forma “Software identification and upgrading”
Table 20 – SICS pro-forma “Replacement time of ODDR unit”
Table 21 – SICS pro-forma “Power consumption”
36 6.1.18 Optional mode switching time
6.2 Standardized test methods for system requirements
Table 22 – SICS pro-forma “Data interface to subsystems and service interface”
Table 23 – SICS pro-forma “Optional mode switching time”
37 Table 24 – Standardized test methods for system requirements
49 7 Arrangements for ODDR Unit type test
7.1 Type test with the integrated ODDRS
7.1.1 General
7.1.2 Equivalent signal generator, power supply
50 7.1.3 Setup of the test environment
Figure 2 – Test configurations at the integrated type test
51 Annex A (informative) FICS and SICS structure and instruction
A.1 FICS and SICS pro-forma
A.1.1 General
A.1.2 Abbreviations used in FICS and SICS tables
A.2 FICS and SICS tables
A.2.1 Identification of FICS and SICS
A.2.2 Identification of the implementation under test
Table A.1 – FICS and SICS identification table
52 A.2.3 Identification of the IUT supplier
A.2.4 Identification of the standards
Table A.2 – IUT identification table
Table A.3 – IUT supplier identification table
Table A.4 – Applicable standards identification table
53 A.2.5 Global statement of conformity
A.2.6 Level of conformity
A.2.7 FICS and SICS tables structure
Table A.5 – Global statement table
54 Table A.6 – FICS and SICS tables format
55 Annex B (informative) Methods for testing the parameter values of the protection capability
B.1 Overview
B.2 General procedure
B.3 Detailed procedure
B.3.1 Protection capability code FA
56 B.3.2 Protection capability code FB
B.3.3 Protection capability code SA
57 B.3.4 Protection capability code SB
B.3.5 Protection capability code PA
B.3.6 Protection capability code CA
Figure B.1 – Impact shock waveform
58 B.3.7 Protection capability code CB
B.3.8 Protection capability code IA
B.3.9 Protection capability code IB
59 B.3.10 Protection capability code HA
B.3.11 Protection capability code MA
60 Bibliography
BS EN 62625-2:2016
$198.66