BS EN IEC 60079-15:2019
$167.15
Explosive atmospheres – Equipment protection by type of protection “n”
Published By | Publication Date | Number of Pages |
BSI | 2019 | 40 |
This part of IEC 60079 specifies requirements for the construction, testing and marking for Group II electrical equipment with type of protection ānā which includes; sealed devices ānCā, hermetically sealed devices ānCā, non-incendive components ānCā and restricted breathing enclosures ānRā intended for use in explosive gas atmospheres. This part of IEC 60079 applies to electrical equipment where the rated input voltage does not exceed 15 kV r.m.s. AC or DC including where the internal working voltages of the Ex product exceeds 15 kV, for example starters for HID luminaires.
This part of IEC 60079 supplements and modifies the general requirements of IEC 60079-0, except as indicated in Table 1. Where a requirement of this part of IEC 60079 conflicts with a requirement of IEC 60079-0, the requirement of this part of IEC 60079 takes precedence.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
8 | Blank Page |
9 | English CONTENTS |
11 | FOREWORD |
16 | 1 Scope Table 1 ā Relationship of IEC 60079-15 to IEC 60079-0 |
22 | 2 Normative references |
23 | 3 Terms and definitions |
24 | 4 General 4.1 Equipment grouping and temperature classification 4.2 Potential ignition sources 4.3 Equipment requirements 5 Maximum surface temperatures |
25 | 6 Requirements for electrical equipment 6.1 General 6.2 Electric strength insulation from earth or frame 7 Requirements for non-incendive components 7.1 Type testing 7.2 Circuit limitations 8 Requirements for hermetically sealed devices |
26 | 9 Requirements for sealed devices 9.1 Non-metallic materials 9.2 Opening 9.3 Internal spaces 9.4 Handling 9.5 Gasket and seals 9.6 Type tests 10 Requirements for restricted-breathing enclosures 10.1 General |
27 | 10.2 Constructional requirements 10.2.1 Type of equipment 10.2.2 Cells and batteries 10.2.3 Cable glands and conduit entries |
28 | 10.2.4 Operating rods, spindles and shafts 10.2.5 Windows 10.2.6 Gasket and seal requirements 10.2.7 Non-resilient seals |
29 | 10.2.8 Test port |
30 | 10.2.9 Internal fans 10.3 Temperature limitation 10.4 Additional requirements for restricted-breathing luminaires 10.4.1 Mounting arrangement 10.4.2 Reflectors 10.4.3 Surface temperatures of restricted-breathing luminaires |
31 | 11 Type Tests 11.1 Tests for non incendive components 11.1.1 Preparation of non-incendive component samples 11.1.2 Test conditions for non-incendive components |
32 | 11.2 Tests for sealed devices 11.2.1 Conditioning 11.2.2 Voltage test 11.2.3 Leakage tests on sealed devices |
33 | 11.3 Type test requirements for restricted-breathing enclosures 11.3.1 General 11.3.2 Equipment where the volume of the enclosure will be unchanged due to pressure 11.3.3 Alternative type test for equipment where the volume of the enclosure changes due to pressure |
34 | 12 Routine verifications and tests 12.1 Electric strength test 12.2 Routine test requirements for restricted-breathing enclosures 12.2.1 General 12.2.2 Test procedure |
35 | 12.3 Routine temperature rise test 12.4 Temperature calculation |
36 | 13 Marking 13.1 General 13.2 Examples of marking 13.3 Warning markings 14 Documentation Table 2 ā Text of warning markings |
37 | 15 Instructions |
38 | Bibliography |