Shopping Cart

No products in the cart.

BS EN IEC 60079-19:2019

$215.11

Explosive atmospheres – Equipment repair, overhaul and reclamation

Published By Publication Date Number of Pages
BSI 2019 86
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of IEC 60079:

  • gives instructions, principally of a technical nature, on the repair, overhaul, reclamation and modification of Ex equipment designed for use in explosive atmospheres;

  • applies to overhaul and repair which mitigates deficiencies identified during operation, inspection and maintenance;

  • does not give advice on cable and wiring systems which can require a renewal when the equipment is re-installed; and

  • is not applicable to Type of Protection “m”.

PDF Catalog

PDF Pages PDF Title
2 undefined
3 ENIEC60079-19{2019}e
5 Annex ZA(normative)Normative references to international publicationswith their corresponding European publications
7 English
CONTENTS
13 FOREWORD
18 INTRODUCTION
19 1 Scope
2 Normative references
20 3 Terms and definitions
25 4 General
4.1 General principles
4.2 Instructions for the user
4.2.1 Ex Equipment Certificates and schedule drawings
26 4.2.2 Records and work instructions
4.2.3 Re-installation of repaired equipment
4.2.4 Service facilities
4.3 Instructions for the service facility
4.3.1 Statutory requirements
4.3.2 Repair and overhaul
31 4.3.3 Reclamations
34 4.3.4 Alterations and modifications
35 4.3.5 Temporary repairs
4.3.6 Electric machines
37 4.3.7 Control equipment
5 Additional requirements for the repair and overhaul of equipmentwith Type of Protection “d”
5.1 Application
38 5.2 Repair and overhaul
5.2.1 Enclosures
39 5.2.2 Water jackets
5.2.3 Entries into enclosures
5.2.4 Terminations
5.2.5 Insulation
5.2.6 Internal connections
5.2.7 Electric machines
40 5.2.8 Auxiliary equipment
41 5.3 Reclamation
5.3.1 General
5.3.2 Enclosures
43 5.3.3 Sleeving
5.3.4 Shafts and housings
5.3.5 Sleeve bearings
5.3.6 Rotors and stators
5.4 Alterations and modifications
5.4.1 Enclosures
5.4.2 Entries into enclosures
44 5.4.3 Terminations
5.4.4 Windings
5.4.5 Auxiliary equipment
6 Additional requirements for the repair and overhaul of equipment with Type of Protection “i”
6.1 Application
45 6.2 Repair and overhaul
6.2.1 Enclosures
6.2.2 Cable glands
6.2.3 Terminations
6.2.4 Soldered connections
46 6.2.5 Fuses
6.2.6 Relays
6.2.7 Shunt diode safety barriers and galvanic isolators
6.2.8 Printed circuit boards
47 6.2.9 Optocouplers and piezoelectric components
6.2.10 Electrical components
6.2.11 Batteries
6.2.12 Internal wiring
48 6.2.13 Transformers
6.2.14 Encapsulated components
6.2.15 Non-electrical parts
6.2.16 Testing
6.3 Reclamation
6.4 Modifications
7 Additional requirements for the repair and overhaul of equipment with Type of Protection “p”
7.1 Application
49 7.2 Repair and overhaul
7.2.1 Enclosures
7.2.2 Entries into enclosures
7.2.3 Terminations
7.2.4 Insulation
7.2.5 Internal connections
50 7.2.6 Electric machines
51 7.2.7 Auxiliary devices
7.2.8 Light-transmitting parts
7.2.9 Encapsulated parts
7.2.10 Batteries
7.2.11 Lamps
7.2.12 Lampholders
7.2.13 Ballasts
7.3 Reclamation
7.3.1 General
7.3.2 Enclosures
52 7.3.3 Shafts and housings
7.3.4 Sleeve bearings
7.3.5 Rotors and stators
7.4 Alterations and modifications
7.4.1 Enclosures
7.4.2 Entries into enclosures
7.4.3 Terminations
53 7.4.4 Windings
7.4.5 Auxiliary equipment
7.5 Pressurization system
8 Additional requirements for the repair and overhaul of equipment with Type of Protection “e”
8.1 Application
54 8.2 Repair and overhaul
8.2.1 Enclosures
8.2.2 Entries into enclosures
8.2.3 Terminations
8.2.4 Insulation
8.2.5 Internal connections
55 8.2.6 Electric machines
57 8.2.7 Light-transmitting parts
8.2.8 Encapsulated parts
58 8.2.9 Batteries
8.2.10 Lamps
8.2.11 Lampholders
8.2.12 Ballasts
8.2.13 Breathing devices
8.3 Reclamation
8.3.1 General
8.3.2 Enclosures
59 8.3.3 Sleeve bearings
8.3.4 Rotors and stators
8.4 Alterations and modifications
8.4.1 Enclosures
8.4.2 Entries into enclosures
8.4.3 Terminations
8.4.4 Windings
60 8.4.5 Auxiliary equipment
9 Additional requirements for the repair and overhaul of equipment with Type of Protection “n”
9.1 Application
9.2 Repair and overhaul
9.2.1 Enclosures
9.2.2 Entries into enclosures
61 9.2.3 Terminations
9.2.4 Insulation
9.2.5 Internal connections
9.2.6 Electric machines
63 9.2.7 Light-transmitting parts
9.2.8 Encapsulated parts
64 9.2.9 Batteries
9.2.10 Lamps
9.2.11 Lampholders
9.2.12 Ballasts
9.2.13 Enclosed break devices
9.2.14 Breathing devices
9.3 Reclamation
9.3.1 General
9.3.2 Enclosures
9.3.3 Joints
65 9.3.4 Shafts and housings
9.3.5 Sleeve bearings
9.3.6 Rotors and stators
9.4 Alterations and modifications
9.4.1 Enclosures
9.4.2 Entries into enclosures
9.4.3 Terminations
9.4.4 Windings
66 9.4.5 Auxiliary equipment
10 Additional requirements for the repair and overhaul of equipment covered by IEC 60079-26
11 Additional requirements for the repair and overhaul of equipment with Type of Protection “t” (formerly “tD” or DIP)
11.1 Application
11.2 Repair and overhaul
11.2.1 Enclosures
67 11.2.2 Entries into enclosures
11.2.3 Terminations
11.2.4 Insulation
11.2.5 Internal connections
11.2.6 Electric machines
68 11.2.7 Light-transmitting parts
11.2.8 Batteries
11.2.9 Lamps
69 11.2.10 Lamp holders
11.2.11 Ballasts
11.2.12 Breathing devices
11.3 Reclamation
11.3.1 General
11.3.2 Enclosures
11.3.3 Joints
11.3.4 Shafts and housings
70 11.3.5 Sleeve bearings
11.3.6 Rotors and stators
11.4 Alterations and modifications
11.4.1 Enclosures
11.4.2 Entries into enclosures
11.4.3 Windings
11.4.4 Auxiliary equipment
12 Requirements for the repair and overhaul of equipment with Type of Protection ”o”
12.1 Application
71 12.2 Repair and overhaul
12.2.1 Associated Types of Protection
12.2.2 Removal of protective liquid
12.2.3 Replacement of components
12.2.4 Preparation for replacing protective liquid
12.2.5 Protective liquid
12.2.6 Closure of container
12.3 Reclamation
72 12.4 Modifications
13 Requirements for the repair and overhaul of equipment with Type of Protection “q”
13.1 Application
13.2 Repair and overhaul
13.2.1 Associated Types of Protection
13.2.2 Removal of protective materials
13.2.3 Replacement of components
13.2.4 Preparation for replacing protective materials
13.2.5 Protective materials
13.2.6 Closure of container
73 13.3 Reclamation
13.4 Modifications
14 Requirements for the repair and overhaul of equipment with Type of Protection “s”
15 Electrical resistance trace heating
74 Annexes
Annex A (normative) Identification of repaired equipment by marking
A.1 Marking information
A.2 Symbols
A.2.1 Repair in accordance with schedule drawings or manufacturer’s specification
A.2.2 Repair in accordance with the Type of Protection standards but not the schedule drawings
Figure A.1 – Repair in accordance with IEC 60079-19 and schedule drawings or manufacturer’s specification
75 A.2.3 Other situations
Figure A.2 – Repair in accordance with the Type of Protection standards but with insufficient evidence of full compliance with the schedule drawings
76 Annex B (normative) Knowledge, skills and competence of responsible persons and operatives
B.1 General
B.2 Knowledge and skills
B.2.1 Responsible persons
B.2.2 Operatives
B.3 Competence
B.3.1 General
77 B.3.2 Responsible persons
B.3.3 Operatives
B.4 Assessment
B.5 Qualification of reclamation operatives
78 Annex C (normative) Requirements for measurements in flame proof equipment during overhaul, repair and reclamation (including guidance on tolerances)
Table C.1 – Determination of maximum gap of reclaimed parts
80 Figure C.1 – Determination of maximum gap of reclaimed parts
81 Annex D (informative) Evaluation of best practice during rewinding and repair
82 Annex E (informative) Additional requirements relating to Ex control equipment
E.1 General
E.2 Common items
E.3 Isolators and circuit interrupters
83 E.4 Interlocks and mechanical linkages
E.5 Earth fault devices
E.6 Other devices
E.7 Transformers
85 Bibliography
BS EN IEC 60079-19:2019
$215.11