BS EN IEC 60730-2-8:2020+A1:2021:2022 Edition
$198.66
Automatic electrical controls – Particular requirements for electrically operated water valves, including mechanical requirements
Published By | Publication Date | Number of Pages |
BSI | 2022 | 68 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
5 | Final version |
6 | English CONTENTS |
8 | FOREWORD |
11 | 1 Scope and normative references |
13 | 2 Terms and definitions |
17 | 3 General requirements 4 General notes on tests 5 Rating 6 Classification |
20 | 7 Information Tables Table 1 ā Required information and methods of providing information Table 101 ā Nominal size and thread size of end connections |
21 | 8 Protection against electric shock |
22 | 9 Provision for protective earthing 10 Terminals and terminations |
23 | 11 Constructional requirements 12 Moisture and dust resistance 13 Electric strength and insulation resistance |
24 | 14 Heating |
25 | 15 Manufacturing deviation and drift 16 Environmental stress |
26 | 17 Endurance |
27 | 18 Mechanical strength |
29 | Table 102 ā Torque test requirement for metal valves with internal threadedend-connections Table 103 ā Torque test requirement for metal valves with external threadedend-connections |
30 | 19 Threaded parts and connections 20 Creepage distances, clearances and distances through insulation 21 Resistance to heat, fire and tracking 22 Resistance to corrosion 23 Electromagnetic compatibility (EMC) requirements ā Emission 24 Components 25 Normal operation |
31 | 26 Electromagnetic compatibility (EMC) requirements ā Immunity 27 Abnormal operation |
32 | Table 104 ā Maximum winding temperature (for test of blocked output conditions and valves declared under Table 1, item 113) |
34 | 28 Guidance on the use of electronic disconnection |
35 | Annexes Annex H (normative) Requirements for electronic controls |
40 | Annex AA (informative) Relation between different flow coefficients |
41 | Annex BB (normative) Arrangement for the measurement of transient pressures caused by water valves |
42 | Figures Figure BB.1 ā Transient pressure measurement test rig schematic diagram |
44 | Annex CC (normative) Long term pressure for test thermosplastic bodied valves Table CC.1 ā Test requirements for valves intended for uses other than the control of water for tap and shower outlets |
45 | Table CC.2 ā Test requirements for valves intended for the control of water for tap and shower outlets |
46 | Annex DD (normative) Torque Figure DD.1 ā Arrangements for carrying out the torque test |
47 | Table DD.1 ā Required torque for test |
49 | Table DD.2 ā Tightening torque in newton metres (Nm) for bolts and screwsfor adaptors |
50 | Annex EE (normative) Arrangement for the measurement of transient pressures caused by water valves with a declared pressure of up to and including 1,0 MPa (10 bar) Figure EE.1 ā Transient pressure measurement test rig for valves with a declared pressure of up to and including 1,0 MPa (10 bar) schematic diagram |
52 | Bibliography |
57 | Annex ZA (normative)Normative references to international publicationswith their corresponding European publications |
62 | FOREWORD |
63 | 1āScope and normative references 1.2āNormative references 10āTerminals and terminations 10.2āTerminals and terminations for internal conductors |
64 | 14āHeating 14.5 14.5.105ā 14.5.106ā 27āAbnormal operation 27.2āBurnout test 27.2.3āBlocked mechanical output test (abnormal temperature test) 27.2.3.1 |
65 | 27.102āRunning overload 27.102.3 |
66 | Annex DD (normative) Torque DD.1 Torque test for valves with internally threaded end-connections according to ISO 7-1 DD.1.1āGeneral DD.1.1.1ā |