BS EN IEC 61076-3-106:2023 – TC

$217.84

Tracked Changes. Connectors for electrical and electronic equipment. Product requirements – Rectangular connectors. Detail specification for protective housings for use with 8-way shielded and unshielded connectors for industrial environments incorporating the IEC 60603-7 series interface

Published By Publication Date Number of Pages
BSI 2023 122
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
1 30479717
79 A-30389542
80 undefined
83 Annex ZA (normative)Normative references to international publicationswith their corresponding European publications
86 English
CONTENTS
89 FOREWORD
91 INTRODUCTION
92 1 Scope
2 Normative references
94 3 Terms and definitions
4 Dimensional information
4.1 Common features
4.2 General
4.3 Contact arrangement of all connector types
4.4 IP65/IP67 sealing
95 4.5 Industrial IEC 60603-7 variant 01 – bayonet coupling
4.5.1 Industrial IEC 60603-7 variant 01, fixed connector
Figures
Figure 1 – Variant 01, fixed connector
Tables
Table 1 – Dimensions for fixed connector variant 01
96 4.5.2 Industrial IEC 60603-7 variant 01, free connector
4.5.3 Mounting information for variant 01, fixed connector
Figure 2 – Variant 01, free connector
Table 2 – Dimensions for free connector variant 01
97 Figure 3 – Variant 01, style 1 mounting drawing
Figure 4 – Variant 01, style 2 mounting drawing
Table 3 – Variant 01, style 1 mounting information
Table 4 – Variant 01, style 2 mounting information
98 4.6 Industrial IEC 60603-7 variant 04 – snap-in coupling
4.6.1 Industrial IEC 60603-7 variant 04, fixed connector
Figure 5 – Variant 04, fixed connector
Table 5 – Dimensions for fixed connector variant 04
99 4.6.2 Industrial IEC 60603-7 variant 04, free connector
Figure 6 – Variant 04, free connector
Table 6 – Dimensions for free connector variant 04
100 4.6.3 Mounting information for variant 04, fixed connector
Figure 7 – Variant 04 mounting drawing
Table 7 – Variant 04 mounting information
101 4.7 Industrial IEC 60603-7 variant 05 – locking lever coupling
4.7.1 Industrial IEC 60603-7 variant 05, fixed connector
Figure 8 – Variant 05, fixed connector
Table 8 – Dimensions for fixed connector variant 05
102 4.7.2 Industrial IEC 60603-7 variant 05, free connector
Figure 9 – Variant 05, free connector
Table 9 – Dimensions for free connector variant 05
103 4.7.3 Mounting information for variant 05, fixed connector
Figure 10 – Variant 05 mounting drawing
Table 10 – Variant 05 mounting information
104 4.8 Industrial IEC 60603-7 variant 06 – snap-in coupling
4.8.1 Industrial IEC 60603-7 variant 06, fixed connector
Figure 11 – Variant 06, fixed connector
Table 11 – Dimensions for fixed connector variant 06
105 4.8.2 Industrial IEC 60603-07 variant 06, free connector
Figure 12 – Variant 06, free connector
Table 12 – Dimensions for free connector variant 06
106 4.8.3 Mounting information for variant 06, fixed connector
Figure 13 – Variant 06 mounting drawing
Table 13 – Variant 06 mounting information
107 4.9 Industrial IEC 60603-7 variant 07 – locking lever coupling
4.9.1 Industrial IEC 60603-7 variant 07, fixed connector side
Figure 14 – Variant 07, fixed connector
Table 14 – Dimensions fixed connector variant 07
108 4.9.2 Industrial IEC 60603-7 variant 07, free connector
Figure 15 – Variant 07, free connector
Table 15 – Dimensions for free connector variant 07
109 4.9.3 Mounting information for variant 07, fixed connector
4.10 Termination information
5 Gauges – Connectors for the IEC 60603-7 interface
6 Characteristics
6.1 Climatic category
Figure 16 – Variant 07 mounting drawing
Table 16 – Variant 07 mounting information
110 6.2 Electrical
6.2.1 Clearance and creepage distances
6.2.2 Voltage proof
Table 17 – Climatic categories – selected values for environmental performance level A
Table 18 – Creepage and clearance
111 6.2.3 Current-carrying capacity
6.2.4 Mating cycles with power applied
6.2.5 Initial contact resistance
Figure 17 – Connector derating curve
112 6.2.6 Input to output resistance
6.2.7 Resistance unbalance
6.2.8 Initial insulation resistance
6.3 Transmission characteristics
6.4 Mechanical
6.4.1 Mechanical operation
6.4.2 Effectiveness of connector coupling devices transversal
6.4.3 Effectiveness of connector coupling devices
113 6.4.4 Engaging and separating forces
7 Test schedule
7.1 General
7.2 Test procedures and measuring methods
7.3 Preconditioning
7.4 Wiring and mounting of specimens
7.4.1 Wiring
114 7.4.2 Mounting
7.5 Arrangement for contact resistance test
7.6 Arrangement for dynamic stress tests
7.7 Basic (minimum) test schedule
7.8 Full test schedule
7.8.1 General
Figure 18 – Vibration and shock test arrangement
115 7.8.2 Test group P – Preliminary
Table 19 – Test group P
116 7.8.3 Test group AP – Dynamic/climatic
Table 20 – Test group AP – Dynamic/climatic
118 7.8.4 Test Group BP – Mechanical
Table 21 – Test Group BP – Mechanical
119 7.8.5 Test group CP – Continuity
7.8.6 Test Group DP
7.8.7 Test Group EP
Table 22 – Test group CP – Continuity
120 Bibliography