Email:[email protected]

IEC 61228:2020 is available as IEC 61228:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61228:2020 describes the method of measuring, evaluating and specifying the UV irradiation characteristics of fluorescent ultraviolet lamps that are used in appliances for tanning purposes. It includes specific requirements regarding the marking of such lamps. This third edition cancels and replaces the second edition published in 2008. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: – maintenance code: description of the depreciation of the UV irradiance lamp during operation; – operating position: information added for single capped lamps; – spectroradiometric measuring system: new information about distance between sensor and lamp axis; – measurement and evaluation procedure: separated detailed information for double capped fluorescent UV lamps and single capped fluorescent UV lamps; – Annex C (normative), Method of test for irradiance maintenance: new information added; – Annex D (normative), Reflector gauge: new information added; – Annex E (normative), Lamp datasheets for measurement: complementary information added.

PDF Catalog

PDF Pages PDF Title
2 undefined
5 Annex ZA(normative)Normative references to international publicationswith their corresponding European publications
7 English
CONTENTS
8 FOREWORD
10 1 Scope
2 Normative references
3 Terms and definitions
12 4 General test conditions
4.1 Ageing
4.2 Operating position
13 4.3 Ambient temperature
4.4 Test voltage
Figure 1 – Measurement position of single capped lamps
Figure 2 – Test circuit
14 4.5 Ballast
5 Test requirements
5.1 General
5.2 Spectroradiometric measuring system
6 Measurement and evaluation procedure
6.1 Measurement
6.1.1 General
6.1.2 Double capped fluorescent UV Lamps
15 6.1.3 Single capped fluorescent UV Lamps
6.2 Calculation of the total effective UV irradiance
Figure 3 – Location of measurement points on lampswith more than one layer
16 6.3 Ambient temperature adjustment
6.4 Reflector angle
6.5 Determination of the lamp maintenance code
7 Lamp specification
17 8 Lamp marking
18 Annex A (normative) Determination of the optimum UV irradiance of fluorescent UV lamps
19 Annex B (normative) Ultraviolet action spectra
Figure B.1 – UV action spectra for erythema and NMSC
20 Table B.1 – Weighting factors S(λ) for erythema and NMSC action spectrum
21 Annex C (normative) Method of test for irradiance maintenance
C.1 General
C.2 Lamps for operation on AC mains frequencies
C.3 Lamps for operation on high frequency
22 Annex D (normative) Reflector gauge
Figure D.1 – Reflector gauge
23 Annex E (normative) Lamp datasheets for measurement
Table E.1 – Lamp dimensions
24 Bibliography