BS EN IEC 61300-3-4:2023
$142.49
Fibre optic interconnecting devices and passive components. Basic test and measurement procedures – Examinations and measurements. Attenuation
Published By | Publication Date | Number of Pages |
BSI | 2023 | 28 |
IEC 61300-3-4:2023 is available as IEC 61300-3-4:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 61300-3-4: 2022 describes the various methods available to measure the attenuation of optical components. It is not, however, applicable to random mate attenuation measurements as described in IEC 61300-3-34 and IEC 61300-3-45 nor for attenuation measurements of dense wavelength division multiplexing (DWDM) devices as described in IEC 61300-3-29. This fourth edition cancels and replaces the third edition published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) addition of Clause 3 containing terms, definitions and abbreviated terms; b) addition of a new LSPM measurement method, insertion method (D); c) addition of Annex A describing attenuation measurement of multicore fibre; d) changed reference test method to insertion C and alternative test method to substitution or insertion D for power meter and type 4 DUT.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
5 | Annex ZA (normative)Normative references to international publicationswith their corresponding European publications |
6 | English CONTENTS |
8 | FOREWORD |
10 | 1 Scope 2 Normative references 3 Terms, definitions and abbreviated terms 3.1 Terms and definitions |
11 | 3.2 Abbreviated terms 4 General description 4.1 General 4.2 Precautions |
12 | 5 Apparatus 5.1 Launch conditions and light source (LS) 5.2 Optical power meter (PM) Tables Table 1 – Preferred source conditions |
13 | 5.3 Temporary joint (TJ) 5.4 Fibre 5.5 Reference plug (RP) 5.6 Reference adaptor (RA) Table 2 – Preferred power meter parameters |
14 | 5.7 Termination 6 Procedure 6.1 Preconditioning 6.2 Visual inspection 6.3 DUT configuration types and test methods |
15 | 6.4 Attenuation measurements with a LSPM 6.4.1 General Table 3 – DUT configuration types |
16 | 6.4.2 Cutback method 6.4.3 Substitution method Figures Figure 1 – Cutback method – Type 1, type 2 and type 3 DUT |
17 | 6.4.4 Insertion method (A) Figure 2 – Substitution method – Type 4, type 7, and type 8 DUT |
18 | 6.4.5 Insertion method (B) with direct coupling to power meter 6.4.6 Insertion method (C) with additional test patchcord Figure 3 – Insertion method (A) – Type 2 DUT Figure 4 – Insertion method (B) – Type 5 and type 6 DUT |
19 | 6.4.7 Insertion method (D) with additional test patchcord Figure 5 – Insertion method (C) – Type 4, type 5, type 7 and type 8 DUT Figure 6 – Insertion method (D) – Type 4, type 5, type 7 and type 8 DUT |
20 | 6.5 Attenuation measurements with an OTDR 6.5.1 Measurement description Figure 7 – Method 1 – One launch section Figure 8 – Method 2 – Two launch sections |
21 | 6.5.2 Bidirectional measurement 6.5.3 Measurement method |
22 | 6.5.4 Evaluation procedure Figure 9 – Non-reflective event evaluation Figure 10 – Reflective event evaluation |
23 | 7 Details to be specified and reported |
24 | Annex A (informative) Consideration of multicore fibre A.1 General A.2 Additional apparatus A.2.1 Optical switch (OSW) A.2.2 Fan-in/fan-out device (FIFO) A.3 Test setup and procedure – LSPM Figure A.1 – FIFO device example |
25 | A.4 Test setup and procedure – OTDR Figure A.2 – Insertion method B – Type 5 MCF DUT Figure A.3 – Method 1 – One launch section MCF DUT |
26 | Bibliography |