BS EN ISO 16119-4:2014
$142.49
Agricultural and forestry machinery. Environmental requirements for sprayers – Fixed and semi-mobile sprayers
Published By | Publication Date | Number of Pages |
BSI | 2014 | 30 |
This part of ISO 16119 specifies requirements and the means for their verification for the design and performance of fixed and semi-mobile sprayers, as defined in 3.1 and 3.2, with regard to minimizing the potential risk of environmental contamination during use, including misuse foreseeable by the manufacturer.
This type of spraying system is generally a combination of separate elements (main tank, pump and application unit) that can be assembled in fixed installations (fixed sprayers) or with moving parts (semi-mobile sprayers).
It does not apply to application equipment for space/spatial treatments.
It is intended to be used with ISO 16119-1, which gives general requirements common to all the sprayer types covered by ISO 16119. When requirements of this part of ISO 16119 are different from those stated in ISO 16119-1, the requirements of this part of ISO 16119 take precedence over the requirements of ISO 16119-1 for machines within the scope of this part of ISO 16119. This part of ISO 16119 does not cover safety aspects (see ISO 4254-6).
This part of ISO 16119 is not applicable to sprayers manufactured before the date of its publication.
PDF Catalog
PDF Pages | PDF Title |
---|---|
4 | Foreword |
5 | Annex ZA (informative) Relationship between this European Standard and the Essential Requirements of EC Directive 2009/127/EC amending 2006/42/EC |
7 | Foreword |
8 | Introduction |
10 | 1 Scope 2 Normative references |
11 | 3 Terms and definitions |
12 | 4 List of significant hazards |
13 | 5 Requirements 5.1 Pump/tank unit 5.1.1 Static leaks 5.1.2 Residual volume 5.1.3 Spray tank(s) |
15 | 5.1.4 Pump |
16 | 5.1.5 Lines (hoses and pipes) 5.1.6 Filters 5.1.7 Measuring systems |
17 | 5.1.8 Provisions for connecting testing equipment 5.2 Adjustment of the dose/volume application rate 5.2.1 General 5.2.2 Pressure adjustment devices 5.2.3 Direct injection system (if provided) |
18 | 5.2.4 Calibration aids 5.3 Application unit 5.3.1 Controls 5.3.2 Pressure drop 5.3.3 Nozzles |
19 | 5.3.4 Horizontal spray boom |
20 | 5.3.5 Vertical spray boom and other non-horizontal spray booms 5.3.6 Spray gun and lance |
21 | 5.3.7 Autonomous application units 5.3.8 Control of spray drift 5.4 Cleaning 5.4.1 Rinsing water tank |
22 | 5.4.2 Cleaning systems 5.5 Cleaning device for plant protection product containers 6 Verification |
24 | 7 Marking 8 Instruction handbook |
25 | Annex A (normative) Backflow measurement method for agitation |
27 | Annex B (normative) Verification of pulsations of the pump |
28 | Bibliography |