BS EN ISO 5840-3:2021
$198.66
Cardiovascular implants. Cardiac valve prostheses – Heart valve substitutes implanted by transcatheter techniques
Published By | Publication Date | Number of Pages |
BSI | 2021 | 66 |
This document is applicable to all devices intended for implantation as a transcatheter heart valve substitute.
This document is applicable to transcatheter heart valve substitutes and to the accessory devices, packaging and labelling required for their implantation and for determining the appropriate size of heart valve substitute to be implanted.
This document establishes an approach for verifying/validating the design and manufacture of a transcatheter heart valve substitute through risk management. The selection of appropriate verification/validation tests and methods are to be derived from the risk assessment. The tests can include those to assess the physical, chemical, biological and mechanical properties of heart valve substitutes and of their materials and components. The tests can also include those for preclinical in vivo evaluation and clinical evaluation of the finished heart valve substitute.
This document defines operational conditions and performance requirements for transcatheter heart valve substitutes where adequate scientific and/or clinical evidence exists for their justification.
This document includes considerations for implantation of a transcatheter heart valve substitute inside a pre-existing prosthetic device (e.g. valve-in-valve and valve-in-ring configurations).
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
4 | European foreword Endorsement notice |
7 | Foreword |
8 | Introduction |
9 | 1 Scope 2 Normative references 3 Terms and definitions |
12 | 4 Abbreviations |
13 | 5 Fundamental requirements 6 Device description 6.1 General |
14 | 6.2 Intended use 6.3 Design inputs 6.3.1 Operational specifications 6.3.2 Performance specifications |
15 | 6.3.3 Implant procedure 6.3.4 Packaging, labelling and sterilization 6.4 Design outputs 6.5 Design transfer (manufacturing verification/validation) 6.6 Risk management |
16 | 7 Design verification and validation 7.1 General requirements 7.2 In vitro assessment 7.2.1 General 7.2.2 Test conditions, sample selection and reporting requirements 7.2.3 Material property assessment 7.2.4 Hydrodynamic performance assessment |
18 | 7.2.5 Structural performance assessment 7.2.6 Design- or procedure-specific testing |
20 | 7.2.7 Device MRI compatibility 7.2.8 Simulated use 7.2.9 Human factors and usability assessment 7.2.10 Implant thrombogenic and haemolytic potential assessment 7.3 Preclinical in vivo evaluation 7.3.1 General |
21 | 7.3.2 Overall requirements |
22 | 7.3.3 Methods |
23 | 7.3.4 Test report |
24 | 7.4 Clinical investigations 7.4.1 General |
25 | 7.4.2 Study considerations |
26 | 7.4.3 Study endpoints |
27 | 7.4.4 Ethical considerations 7.4.5 Pivotal studies: Distribution of subjects and investigators |
28 | 7.4.6 Statistical considerations including sample size and duration |
30 | 7.4.7 Patient selection criteria 7.4.8 Valve thrombosis prevention |
31 | 7.4.9 Clinical data requirements |
36 | Annex A (informative) Description of the transcatheter heart valve system |
38 | Annex B (informative) Transcatheter heart valve substitute hazard analysis example |
40 | Annex C (informative) Guidelines for verification of hydrodynamic performance — Pulsatile flow testing |
48 | Annex D (normative) Requirements for delivery system design and evaluation |
50 | Annex E (informative) Examples of design specific testing |
52 | Annex F (informative) Preclinical in vivo evaluation |
55 | Annex G (normative) Adverse event classification during clinical investigation |
61 | Annex H (informative) Multimodality imaging of TAVI and TMVI pre, peri and post-implantation assessments — Examples |
64 | Bibliography |