Dentistry. Mixing machines for dental amalgam
Published By | Publication Date | Number of Pages |
BSI | 2018 | 22 |
This document specifies requirements for electrically-powered mixing machines for mixing dental amalgam alloy, and dental mercury in capsules to produce dental amalgam.
This document specifies the test methods used to determine conformity with these requirements.
This document refers to those machines that mix by an oscillating action and which are sold by the manufacturer for the purpose of mixing dental amalgam whether or not they are intended for mixing any other type of product.
This document does not specify requirements for removable mixing-capsules, as are used in many machines to contain the material to be mixed, although considered as part of the machine when in use or under test.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | National foreword |
4 | European foreword |
7 | Foreword |
8 | Introduction |
9 | 1 Scope 2 Normative references 3 Terms and definitions |
10 | 4 Requirements 4.1 Safety 4.1.1 Electrical 4.1.2 Mechanical 4.2 Stability |
11 | 4.3 Sound pressure 4.4 Frequency 4.4.1 General 4.4.2 Variable-power machines 4.5 Amplitude 4.6 Mixing time 4.6.1 Timing device 4.6.2 Timing settings |
12 | 4.7 Coherence time 4.8 Long-term test 5 Sampling 5.1 Mixing machine 5.2 Mixing-capsules 5.2.1 General 5.2.2 Mixing-capsule selection |
13 | 5.3 Test components 6 Measurement and test methods 6.1 Test conditions 6.1.1 General 6.1.2 Reference charge mass, mref 6.1.3 Minimum charge mass, mmin 6.1.4 Maximum charge mass, mmax 6.1.5 Maximum running duration, tmax 6.1.6 Power supply conditions and apparatus |
14 | 6.1.7 Equipment setup 6.2 Visual inspection 6.3 Sound pressure 6.3.1 Apparatus and setup |
15 | 6.3.2 Procedure 6.3.3 Variable-power machines 6.4 Frequency tests 6.4.1 Measurement of mixing-capsule oscillation frequency |
16 | 6.5 Working length 6.5.1 Principle 6.5.2 Apparatus 6.5.3 Procedure 6.6 Amplitude 6.6.1 Apparatus 6.6.2 Procedure |
17 | 6.7 Mixing time 6.7.1 Apparatus 6.7.2 Procedure 6.8 Coherence time 6.8.1 Apparatus and materials 6.8.2 Procedure |
18 | 6.9 Long-term test |
19 | 7 Instructions for use 7.1 General 7.2 Identification 7.3 Safety 7.4 User maintenance 7.5 Other maintenance 7.6 Mixing-capsule requirements 7.7 Mixing-capsule amplitude 7.8 Operational limitations 7.8.1 Mixing machine limitations |
20 | 7.8.2 Mass and frequency 8 Packaging 9 Marking 9.1 On the mixing-machine 9.2 On the packaging |
21 | Bibliography |