BS IEC 60092-503:2021 – TC:2022 Edition
$186.33
Tracked Changes. Electrical installations in ships – Special features. AC supply systems with voltages in the range of above 1 kV up to and including 36 kV
Published By | Publication Date | Number of Pages |
BSI | 2022 | 68 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
42 | undefined |
44 | CONTENTS |
46 | FOREWORD |
48 | INTRODUCTION |
49 | 1 Scope 2 Normative references |
50 | 3 Terms and definitions |
51 | 4 General requirements 4.1 Environmental conditions 4.2 System design 4.3 Personnel safety 4.4 Operational safety 4.5 Integrity of external power supply |
52 | 4.6 Electrical and mechanical interlockings 4.7 Selection criteria for distribution systems 4.8 Distribution systems network earthing |
53 | 4.9 Divided system 5 Insulation 5.1 Selection of insulation level 5.1.1 General 5.1.2 Lightning impulse withstand voltage 5.1.3 Consideration of rated withstand voltages 5.2 Verification of clearance and creepage distances 5.2.1 Clearance distance |
54 | 5.2.2 Creepage distance 5.3 Voltage and frequency Table 1 – Minimum clearance |
55 | 6 Electrical protection 6.1 General 6.2 Voltage-transformer protection 6.3 Overvoltage protection Table 2 – AC three-phase systems having a nominal voltage above 1 kV and up to and including 36 kV |
56 | 6.4 Earth-fault monitoring 7 High voltage equipment 7.1 General 7.1.1 Ingress protection 7.1.2 Earthing of current and voltage transformers 7.1.3 Safe earthing measures Table 3 – Minimum IP ratings |
57 | 7.1.4 Accumulation of moisture and condensation 7.1.5 Liquid cooling 7.1.6 Terminals 7.2 Switchgear and controlgear assemblies 7.2.1 Design and construction |
58 | 7.2.2 Handrails 7.2.3 Door opening 7.2.4 Encapsulation 7.2.5 Internal arc classification 7.2.6 Continuous (common) busbar compartment |
59 | 7.2.7 Busbars of main switchboards 7.2.8 Generator circuits 7.2.9 Outgoing circuits 7.2.10 Power-transformer circuits 7.2.11 Shore-connection circuits 7.2.12 Earthing switches |
60 | 7.2.13 Earthing of equipment 7.2.14 Auxiliary circuits 7.3 Generators and motors 7.3.1 General 7.3.2 Installation 7.3.3 Encapsulation 7.3.4 Temperature monitoring 7.3.5 Stator winding circuit arrangement 7.3.6 De-excitation |
61 | 7.4 Transformers and reactors 7.4.1 General 7.4.2 Enclosures and installation 7.4.3 Encapsulation 7.4.4 Temperature monitoring 7.5 Converters 7.5.1 General 7.5.2 Encapsulation |
62 | 7.6 Cables 7.6.1 General 7.6.2 Installation 7.6.3 Conductors and terminations 7.6.4 Testing |
63 | 7.7 System test 8 Installation requirements for high voltage equipment 8.1 Access 8.2 Identification and marking 8.2.1 General 8.2.2 Labelling |
64 | 8.2.3 Information plates and warning plates 8.2.4 Installations with incorporated capacitors |
65 | Bibliography |