Shopping Cart

No products in the cart.

BS IEC 62153-4-15:2015

$167.15

Metallic Communication Cable test methods – Electromagnetic compatibility (EMC). Test method for measuring transfer impedance and screening attenuation or coupling attenuation with triaxial cell

Published By Publication Date Number of Pages
BSI 2015 44
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of IEC 62153 specifies the procedures for measuring with triaxial cell the transfer impedance, screening attenuation or the coupling attenuation of connectors, cable assemblies and components, e.g. accessories for analogue and digital transmission systems and equipment for communication networks and cabling (in accordance with the scope of IEC technical committee 46).

Measurements can be achieved by applying the device under test direct to the triaxial cell or with the tube in tube method in accordance with IEC 62153-4-7.

PDF Catalog

PDF Pages PDF Title
4 CONTENTS
7 FOREWORD
9 1 Scope
2 Normative references
10 3 Terms and definitions
Figures
Figure 1 – Definition of ZT
12 4 Physical background
5 Principle of the test methods
5.1 General
Tables
Table 1 – IEC 62153-4-x, Metallic communication cable test methods – Test procedures with triaxial test set-up
13 5.2 Transfer impedance
Figure 2 – Principle depiction of the triaxial cell to measure transfer impedance and screening attenuation
Figure 3 – Principle depiction of the triaxial cell to measure transfer impedance and screening attenuation of assemblies with tube in tube according to IEC 62153-4-7
14 5.3 Screening attenuation
5.4 Coupling attenuation
15 5.5 Tube in tube method
6 Test procedures
6.1 General
6.2 Triaxial cell
6.3 Cut off frequencies, higher order modes
16 6.4 Test equipment
6.5 Calibration procedure
17 6.6 Test leads and connecting cables to DUT
7 Sample preparation
7.1 Coaxial connector or assembly or quasi-coaxial component
7.2 Balanced or multipin connector or component
18 7.3 Cable assemblies
Figure 4 – Preparation of balanced or multipin connectors for transfer impedance and screening attenuation
Figure 5 – Preparation of balanced or multipin connectors for coupling attenuation measurement
19 7.4 Other screened devices
8 Transfer impedance (short – matched)
8.1 General
8.2 Principle block diagram of transfer impedance
Figure 6 – Test set-up (principle) for transfer impedance measurement according to test method B of IEC 62153-4-3
20 8.3 Measuring procedure
8.4 Evaluation of test results
8.5 Test report
21 9 Screening attenuation
9.1 General
9.2 Impedance matching
9.3 Measuring with matched conditions
9.3.1 Procedure
9.3.2 Evaluation of test results
22 9.4 Measuring with mismatch
9.4.1 General
9.4.2 Evaluaton of test results
23 9.5 Test report
10 Coupling attenuation
10.1 Procedure
10.2 Expression of results
24 10.3 Test report
11 Coupling transfer function
25 Annexes
Annex A (informative) Principle of the triaxial test procedure
Figure A.1 – Principle test set-up to measure transfer impedance and screening attenuation
Figure A.2 – Equivalent circuit of the principle test set-up in Figure A.1
27 Annex B (informative) Triaxial cell
Figure B.1 – Principle depiction of the triaxial cell to measure transfer impedance and screening attenuation at HV-assemblies with tube in tube according to IEC 62153-4-7
28 Figure B.2 – Example of different designs of triaxial cells
29 Annex C (informative) Cut off frequencies, higher order modes
Table C.1 – Resonance frequencies of different triaxial cells
30 Figure C.1 – Comparison of the measurements with tube and with triaxial cell of a RG 11 cable with single braid construction, linear scale
31 Figure C.2 – Comparison of the measurements with tube and with triaxial cell of a cable RG 11 with single braid construction, log scale
32 Annex D (informative) Coupling transfer function
Figure D.1 – Measured coupling transfer function of a braided screen vs. frequency with the triaxial cell
34 Annex E (informative) Attenuation versus scattering parameter S21
Figure E.1 – Measurement with HP8753D of S21 of a 3dB attenuator
35 Figure E.2 – Measurement with ZVRE of S21 of a 3dB attenuator
36 Annex F (informative) Application of a moveable shorting plane
F.1 Effect of the measurement length on the measurement cut-off frequency
F.2 Details of the movable shorting plane
Figure F.1 – Crosssection of triaxial cell with movable shorting plane
37 Figure F.2 – Crosscut of plane shortening housing and tube-in-tube
Figure F.3 – Detail H of figure F.2: contact between plane and housing
38 F.3 Measurement results
Figure F.4 – Detail G of figure F.2: contact between plane and tube-in-tube
Figure F.5 – Compilation of transfer impedance test results with different shorting plane distances
39 Annex G (informative) Correction in case the receiver input impedance R is higher than the characteristic impedance of the outer circuit Z2
Figure G.1 – Example of forward transfer scattering parameter S21 for different impedances in the outer circuit where the receiver input impedance is 50Ω
40 Figure G.2 – DUT with uniform cylindrical shape in the centre of the cell
41 Bibliography
BS IEC 62153-4-15:2015