Eyewear display – Fundamental measurement methods. Optical properties

Published By Publication Date Number of Pages
BSI 2019 34
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

IEC 63145-20-10:2019(E) specifies the standard measurement conditions and measurement methods for determining the optical properties of eyewear displays. This document applies to non-see-through type (virtual reality “VR” goggles) and see-through type (augmented reality “AR” glasses) eyewear displays using virtual image optics. Contact lens-type displays and retina direct projection displays are out of the scope of this document.

PDF Catalog

PDF Pages PDF Title
2 National foreword
4 CONTENTS
6 FOREWORD
8 1 Scope
2 Normative references
3 Terms, definitions, abbreviated terms and letter symbols
3.1 Terms and definitions
9 3.2 Abbreviated terms
3.3 Letter symbols (symbols for quantities and units)
10 4 Standard measurement conditions
4.1 Standard environmental conditions
4.2 Power supply
4.3 Warm-up time
Table 1 – Letter symbols (symbols for quantities and units)
11 4.4 Dark room condition
5 Measurement systems
5.1 Standard coordinate system
Figures
Figure 1 – Spherical coordinate system
12 5.2 Measurement equipment
5.2.1 Light measuring device (LMD)
Figure 2 – Three-dimensional Cartesian coordinate system
13 5.2.2 Stage conditions
Figure 3 – Example of LMD structure
14 5.2.3 Setup conditions
15 Figure 4 – Examples of measurement setup
16 5.3 Test patterns
5.3.1 General
5.3.2 Checkerboard pattern
5.3.3 Solid colour patterns
5.4 Measuring points
Figure 5 – Example of 5 x 5 checkerboard pattern
17 6 Measurement methods for optical characteristics
6.1 General
6.2 Preparation
Figure 6 – Measuring points for the centre and multi-point measurement
18 6.3 Luminance and luminance uniformity (non-uniformity)
6.3.1 General
6.3.2 Measurement procedure
6.3.3 Calculation
19 6.3.4 Report
6.4 Chromaticity and colour gamut
6.4.1 General
6.4.2 Measurement procedure
6.4.3 Calculation
20 6.4.4 Report
6.5 Chromaticity uniformity
6.5.1 General
6.5.2 Measurement procedure
6.5.3 Calculation
6.5.4 Report
21 6.6 Contrast ratio
6.6.1 General
6.6.2 Measurement procedure
6.6.3 Calculation
6.6.4 Report
22 6.7 Field of view (FOV)
6.7.1 General
6.7.2 Measurement procedure
23 6.7.3 Calculation
Figure 7 – Example of FOV boundary
24 6.7.4 Report
25 6.8 Eye-box based on luminance
6.8.1 General
6.8.2 Measurement procedure
26 6.8.3 Report
6.9 Pixel angular density
6.9.1 General
6.9.2 Measurement procedure
Figure 8 – Example of pixel angular density measurement
27 6.9.3 Report
28 Annex A (informative)Estimating the eye point
A.1 General
A.2 Eye point based on full field luminance method
A.2.1 General
A.2.2 Measurement procedure
29 A.3 Eye point based on Michelson contrast method
A.3.1 General
A.3.2 Measurement procedure
Figure A.1 – Example of luminance image
30 Figure A.2 – Example of image of resolution test pattern
31 Annex B (informative)Explanation of measurement results
B.1 Geographic coordinate chart
B.2 Visual field
Figure B.1 – Example of geographic coordinate chart
32 Figure B.2 – Example of visual field
33 Bibliography