BS ISO 21360-3:2019
$142.49
Vacuum technology. Standard methods for measuring vacuum pump performance – Specific parameters for mechanical booster vacuum pumps
Published By | Publication Date | Number of Pages |
BSI | 2019 | 24 |
This document specifies methods and special requirements for measuring the maximum tolerable pressure difference, effective compression ratio, compression ratio with zero throughput and overflow valve pressure difference of mechanical booster vacuum pumps.
It applies to mechanical booster vacuum pumps employed for medium vacuum or rough vacuum applications including gas-cooled mechanical booster vacuum pump and multiple mechanical booster vacuum pump systems.
It covers particular characteristics of mechanical boosters that are different from those of the usual positive displacement vacuum pumps. Maximum tolerable pressure difference Δpmax, effective compression ratio Keff, compression ratio with zero throughput K0 and overflow valve pressure difference Δp1 are special characteristics of the performance of mechanical booster vacuum pumps.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | National foreword |
6 | Foreword |
7 | Introduction |
9 | 1 Scope 2 Normative references 3 Terms and definitions |
10 | 4 Symbols |
11 | 5 Measurement conditions 6 Experimental setup 6.1 General 6.2 Schematic diagram |
13 | 6.3 Test dome on test pump 6.4 Buffer volume on backing line 6.5 Vacuum gauges 7 Test methods 7.1 Measurement of maximum tolerable pressure difference, Δpmax 7.1.1 General 7.1.2 Measuring method 7.1.3 Measuring procedure |
14 | 7.1.4 Measurement uncertainty 7.1.5 Evaluation of the measurement 7.1.6 Test report 7.2 Measurement report of compression ratio K0 7.2.1 General 7.2.2 Test report 7.3 Measurement of the effective compression ratio Keff 7.3.1 Backing pump selection 7.3.2 Test report |
15 | 7.4 Measurement of overflow valve pressure difference Δp1 7.4.1 General 7.4.2 Determination of overflow valve pressure difference 7.4.3 Measuring method 7.4.4 Measuring procedure 7.4.5 Overflow valve opening 7.4.6 Measurement uncertainty 7.4.7 Evaluation of the measurement 7.4.8 Test report |
16 | 8 Test report 8.1 Content 8.2 Report on pump parameters 8.3 Report on test equipment and conditions 8.4 Report on operational parameters |
17 | Annex A (normative) Test dome |
18 | Annex B (informative) Backing line and returning cooled-gas line |
20 | Annex C (informative) Measuring uncertainties |
22 | Bibliography |