BS ISO 4965-1:2012:2013 Edition

$142.49

Metallic materials. Dynamic force calibration for uniaxial fatigue testing – Testing systems

Published By Publication Date Number of Pages
BSI 2013 24
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of ISO 4965 describes two methods (see Introduction) for determining the relationship between the dynamic force range (ΔFt) applied to a test-piece in a uniaxial, sinusoidal, constant amplitude test and the force range indicated (ΔFi) by the testing system.

These methods are applicable to dynamic testing systems operating away from system resonant frequencies and are relevant to testing systems where the dynamic force measurement errors are either unknown or where they are expected to exceed 1 % of the applied force range.

The dynamic force measurement errors are determined by comparison of the peak forces indicated by the dynamic testing system with those measured by the strain gauged dynamic calibration device (DCD). This DCD has previously undergone static calibration (see 5.2.1) against the testing system indicator.

For Method A (Replica test-piece method), the dynamic calibration is applicable over the validated range of frequencies for that type of test-piece only. A frequency-dependent correction factor is applicable for the correction of dynamic force measurement errors of up to 10 % of dynamic force range. By using such a correction factor, the actual test-specimen dynamic force measurement error will be reduced to less than 1 % of the dynamic force range.

For Method B (Compliance envelope method), the dynamic calibration is applicable over the range of test frequencies validated for test-pieces whose compliance lies between those of the two DCDs. No correction factor is applicable, as Method B does not permit dynamic force measurement errors above 1 % of the dynamic force range.

NOTE Annex A provides guidance on when the system should be re-calibrated by the methods described in this part of ISO 4965.

PDF Catalog

PDF Pages PDF Title
3 CVP_Secretariat_Loca
6 Foreword
7 Introduction
9 1 Scope
2 Normative references
3 Terms, definitions, and symbols
11 4 General requirements
4.1 Temperature
4.2 Dynamic testing system
13 5 Procedure
5.1 Initial checks
14 5.2 Calibration procedure
15 6 Calculation of results
6.1 Calculate DCD forces and measured force ranges
16 6.2 Replica test-piece — Method A
6.3 Compliance envelope — Method B
17 7 Report
7.1 General information
18 7.2 Results of dynamic calibration
7.3 Re-calibration
19 Annex A
(normative)

Guidance on re-calibration to be supplied to the user

20 Annex B
(informative)

Guidance on estimation of the bandwidth of the testing system instrumentation

21 Bibliography
BS ISO 4965-1:2012
$142.49