BS ISO/IEC 14763-4:2021
$102.76
Information technology. Implementation and operation of customer premises cabling – Measurement of end-to-end (E2E) links, modular plug terminated links (MPTLs) and direct attach cabling
Published By | Publication Date | Number of Pages |
BSI | 2021 | 22 |
This part of ISO/IEC 14763 specifies the measurement of two- and four-pair balanced cabling of
-
end-to-end (E2E) link Class D, E and EA;
-
modular plug terminated links (MPTLs) of Class D, E, EA, F, FA and of Class I and II;
-
direct attach cabling of Class D, E, EA, F, FA and of Class I and II.
The free connectors which terminate two and four pairs in field and laboratory conditions are included.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
4 | CONTENTS |
6 | FOREWORD |
8 | INTRODUCTION |
9 | 1 Scope 2 Normative references |
10 | 3 Terms, definitions and abbreviated terms 3.1 Terms and definitions 3.2 Abbreviated terms 4 Conformance 5 Transmission performance of E2E links, MPTLs and direct attach cabling 6 Transmission limits of E2E link, MPTLs and direct attach cabling Tables Table 1 – Transmission performance limits |
11 | 7 Reference planes of E2E link, MPTL and direct attach cabling 7.1 Reference planes of E2E link 7.2 Reference planes of MPTL Figures Figure 1 – Reference planes of E2E links |
12 | 7.3 Reference planes of direct attach cabling Figure 2 – Reference planes of 2-connection MPTL Figure 3 – Reference planes of 3-connection MPTL |
13 | 8 Testing 8.1 General 8.2 Laboratory testing of E2E link, MPTL and direct attach cabling 8.3 Field testing of E2E link, MPTL and direct attach cabling 8.3.1 Basic criteria Figure 4 – Reference planes of direct attach cabling |
14 | 8.3.2 Requirements of field test equipment 8.3.3 Field test measurement parameters 9 Test head requirements 9.1 General 9.2 Additional test head requirements in accordance with the IEC 60603-7 series Table 2 – Overview level for field test equipment of performance of E2E link, direct attach cabling and MPTLs |
15 | 9.3 Test head requirements of IEC 61076-2-101 9.4 Test head requirements of IEC 61076-2-109 |
16 | Annex A (informative)Example performance of E2E link test heads A.1 Example Category 5 test head performance A.2 Example Category 6 test head performance Table A.1 – Example performance of free connector de-embedded NEXT for Category 5 E2E test heads in the frequency range 50 MHz ≤ f < 100 MHz |
17 | Table A.2 – Example performance of free connector de-embedded NEXT for Category 6 E2E test heads in the frequency range 50 MHz ≤ f < 250 MHz |
18 | Annex B (normative)Test regime for reference performance and installation performance of E2E link, MPTL and direct attach cabling Table B.1 – Reference Classes of E2E link, direct attach cabling and MPTL Table B.2 – Test regime for reference performance and installationperformance of E2E link, direct attach cabling and MPTL |
20 | Bibliography |