Shopping Cart

No products in the cart.

BSI PD CLC/TS 50677:2022 – TC

$246.62

Tracked Changes. Clothes washing machines and washer-dryers for household and similar use. Method for the determination of rinsing effectiveness by measurement of the surfactant content at textile materials

Published By Publication Date Number of Pages
BSI 2022 100
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This document provides a method for the evaluation of the rinsing effectiveness of household clothes washing machines, washer dryers and commercial washing machines. The amount of residual linear alkylbenzene sulfonate surfactant (LAS) extracted from the unstained test swatches of the strips used in the washing performance test is determined. This is accomplished by measuring the ultraviolet (UV) light absorbance at the wavelength particular to LAS, a key ingredient of the detergent. Assuming a fixed linear relationship between LAS amount and quantity of detergent mixture and using a concentration versus absorbance curve developed as part of this procedure, the absorbance values are then converted into detergent concentrations, which together with the test solution mass data, yields detergent quantities. This assumption is done, because in the frame of this test it is not possible to determine the exact amount of LAS involved, even in the concentration curves, but only the amount of detergent used. On the textiles, this linear relationship is not given, but it is nevertheless used to express the amount of LAS as determined by UV light absorbance measurements in terms of a detergent amount.

PDF Catalog

PDF Pages PDF Title
1 30460053
55 A-30443353
56 undefined
62 1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviated terms
4.1 The variables for rinsing effectiveness calculations are defined as:
63 4.2 Symbols relating to ‎Annex A
5 Requirements
6 Test method
6.1 Equipment and materials
6.1.1 General
64 6.1.2 Climate chamber
6.1.3 Ultraviolet (UV) spectrophotometer
6.1.4 Quartz cuvette
6.1.5 Cuvette rack
6.1.6 Orbital shaker
6.1.7 Scale for weighing detergent and samples
6.1.8 Weigh bowl
65 6.1.9 Volumetric flask
6.1.10 Graduated cylinder, 500 ml
6.1.11 Magnetic stirrer
6.1.12 Magnetic stir bar
6.1.13 Pipette
6.1.14 Disposable glass pipettes (e.g. Pasteur pipettes)
6.1.15 Pipette bulbs, 2 ml or greater
6.1.16 Sample bottle with cap (for test swatch extraction)
6.1.17 Laboratory wipes
6.1.18 Distilled water
6.1.19 Squirt bottle
6.1.20 Funnel
66 6.1.21 Reference detergent A* base powder
6.2 Preparation of equipment
6.2.1 General
6.2.2 UV spectrophotometer check
6.2.3 Cleanliness
6.2.4 Cuvette filling and cleaning
6.2.5 Checking the quality of the distilled water
6.2.5.1 General
67 6.2.5.2 Spectrum from 200 nm to 350 nm
68 6.2.5.3 Calculation of net absorbance (223 nm – 330 nm)
6.2.5.4 Calculation of relative peak absorbance
69 6.2.6 Cuvette matching
70 6.3 Procedure
6.3.1 Detergent concentration curve
6.3.1.1 General
6.3.1.2 Frequency for determining detergent concentration curve
6.3.1.3 Procedure for determining detergent concentration curve
6.3.2 Test run procedure
6.3.2.1 Prepare the load for performance test according to IEC / EN
6.3.2.2 Perform the test run as specified in of EN 60456:2016/A11:2020, Clause 8 or EN IEC 62512:2020/A11:2020, Clause 8 with the following changes
6.3.3 Acquiring samples
71 6.3.4 UV absorbance measurements
6.3.4.1 Preparation of equipment
6.3.4.2 Preparation of blank
72 6.3.4.3 Preparation and reading of specimens from extracted water samples
6.4 Expression of results
6.4.1 Rinsing effectiveness
75 6.4.2 Rinsing effectiveness evenness
7 Data to be reported
76 Annex A (normative)Procedure for determining a detergent concentration curve
A.1 General approach
A.2 IEC-A* base detergent sampling
A.3 Distilled water
A.4 Preparation of Stock 1 solution (IEC-A* base powder detergent)
A.4.1 Sample weighing
A.4.2 Mix the sample
77 A.4.3 Stock 1 calculation
A.5 Preparation of Stock 2
A.5.1 Mix the sample
A.5.2 Stock 2 calculation
78 A.6 Preparation of working standards
A.6.1 Mix the solutions
79 A.6.2 Working standard calculations
A.7 Measure the absorbance of the working standard solutions
80 A.8 Calculations
A.8.1 Initial treatment of the data
A.8.2 Single sample data (per detergent sample)
A.8.3 Combined sample data (all detergent samples)
82 Annex B (normative)IEC-A* base powder detergent sampling
B.1 Purpose
B.2 Devices and materials
B.3 Sampling procedure
86 Annex C (informative)Acquiring samples using a dispenser
C.1 General
C.2 Calibration of the dispenser
C.2.1 General
C.2.2 Priming
C.2.3 Setting the volume
C.2.4 Calibration:
87 C.2.5 Calculation:
C.3 Acquiring samples (with dispenser)
88 Annex D (informative)Quartz cuvette and glassware cleaning and handling
D.1 Purpose
D.2 Cuvettes
D.3 General cleaning
89 D.4 Periodic glass cleaning
D.4.1 General
D.4.2 Standard glassware cleaning solutions
90 Annex E (informative)Uncertainty of the test method
91 Annex F (informative)Extraction of single swatches
F.1 General
F.2 Additional materials
F.2.1 Graduated cylinder, 100 ml
F.2.2 Sample bottle with cap (for test swatch extraction)
F.3 Single extraction
93 Annex G (normative)Test report – Data to be reported
G.1 General
G.2 Data for test machine
G.3 Data, parameters and results for the test series
95 G.4 Example of calibration data collection (including calculation)
97 G.5 Example of data collection for measurement
BSI PD CLC/TS 50677:2022 - TC
$246.62