Shopping Cart

No products in the cart.

ICC International Residential Code (IRC) 2000

$31.96

International Residential Code

Published By Publication Date Number of Pages
ICC 2000 578
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This document reflects the latest technological advances in building design and construction and is a companion to the IBC.Among the technical changes are new provisions for prescriptive steel framing and energy criteria. This code also contains mechanical, fuel gas and plumbing provisions that coordinate with the International Mechanical Code®, International Fuel Gas Code® and International Plumbing Code®.

PDF Catalog

PDF Pages PDF Title
1 INTERNATIONAL RESIDENTIAL CODE
2 COPYRIGHT INFORMATION
3 PREFACE
5 SAMPLE ORDINANCE FOR ADOPTION
7 TABLE OF CONTENTS
13 Part I — Administrative
CHAPTER 1: ADMINISTRATION
Section R101 — TITLE, SCOPE AND PURPOSE
Section R102 — APPLICABILITY
Section R103 — DEPARTMENT OF BUILDING SAFETY
Section R104 — DUTIES AND POWERS OF THE BUILDING OFFICIAL
14 Section R105 — PERMITS
16 Section R106 — CONSTRUCTION DOCUMENTS
17 Section R107 — TEMPORARY STRUCTURES AND USES
Section R108 — FEES
Section R109 — INSPECTIONS
18 Section R110 — CERTIFICATE OF OCCUPANCY
19 Section R111 — SERVICE UTILITIES
Section R112 — BOARD OF APPEALS
Section R113 — VIOLATIONS
20 Section R114 — STOP WORK ORDER
21 Part II — Definitions
CHAPTER 2: DEFINITIONS
Section R201 — GENERAL
Section R202 — DEFINITIONS
33 Part III — Building Planning and Construction
CHAPTER 3: BUILDING PLANNING
Section R301 — DESIGN CRITERIA
54 Section R302 — LOCATION ON LOT
Section R303 — LIGHT, VENTILATION AND HEATING
55 Section R304 — MINIMUM ROOM AREAS
Section R305 — CEILING HEIGHT
Section R306 — SANITATION
56 Section R307 — TOILET, BATH AND SHOWER SPACES
57 Section R308 — GLAZING
58 Section R309 — GARAGES AND CARPORTS
59 Section R310 — EMERGENCY ESCAPE AND RESCUE OPENINGS
Section R311 — EXITS
Section R312 — LANDINGS
60 Section R313 — RAMPS
Section R314 — STAIRWAYS
61 Section R315 — HANDRAILS
Section R316 — GUARDS
Section R317 — SMOKE ALARMS
62 Section R318 — FOAM PLASTIC
Section R319 — FLAME SPREAD AND SMOKE DENSITY
Section R320 — INSULATION
63 Section R321 — DWELLING UNIT SEPARATION
64 Section R322 — MOISTURE VAPOR RETARDERS
Section R323 — PROTECTION AGAINST DECAY
65 Section R324 — PROTECTION AGAINST TERMITES
66 Section R325 — SITE ADDRESS
Section R326 — ACCESSIBILITY
Section R327 — FLOOD-RESISTANT CONSTRUCTION
69 CHAPTER 4: FOUNDATIONS
Section R401 — GENERAL
Section R402 — MATERIALS
70 Section R403 — FOOTINGS
78 Section R404 — FOUNDATION WALLS
88 Section R405 — FOUNDATION DRAINAGE
Section R406 — FOUNDATION WATERPROOFING AND DAMPPROOFING
90 Section R407 — COLUMNS
Section R408 — UNDER-FLOOR SPACE
91 CHAPTER 5: FLOORS
Section R501 — GENERAL
Section R502 — WOOD FLOOR FRAMING
98 Section R503 — FLOOR SHEATHING
100 Section R504 — PRESSURE PRESERVATIVELY TREATED-WOOD FLOORS (ON GROUND)
Section R505 — STEEL FLOOR FRAMING
113 Section R506 — CONCRETE FLOORS (ON GROUND)
115 CHAPTER 6: WALL CONSTRUCTION
Section R601 — GENERAL
Section R602 — WOOD WALL FRAMING
134 Section R603 — STEEL WALL FRAMING
177 Section R604 — WOOD STRUCTURAL PANELS
Section R605 — PARTICLEBOARD
Section R606 — GENERAL MASONRY CONSTRUCTION
185 Section R607 — UNIT MASONRY
187 Section R608 — MULTIPLE WYTHE MASONRY
Section R609 — GROUTED MASONRY
189 Section R610 — GLASS UNIT MASONRY
191 Section R611 — INSULATING CONCRETE FORM WALL CONSTRUCTION
210 Section R612 — CONVENTIONALLY FORMED CONCRETE WALL CONSTRUCTION
Section R613 — EXTERIOR WINDOWS AND GLASS DOORS
213 CHAPTER 7: WALL COVERING
Section R701 — GENERAL
Section R702 — INTERIOR COVERING
216 Section R703 — EXTERIOR COVERING
225 CHAPTER 8: ROOF-CEILING CONSTRUCTION
Section R801 — GENERAL
Section R802 — WOOD ROOF FRAMING
249 Section R803 — ROOF SHEATHING
Section R804 — STEEL ROOF FRAMING
260 Section R805 — CEILING FINISHES
261 Section R806 — ROOF VENTILATION
Section R807 — ATTIC ACCESS
Section R808 — INSULATION CLEARANCE
263 CHAPTER 9: ROOF ASSEMBLIES
Section R901 — GENERAL
Section R902 — ROOF CLASSIFICATION
Section R903 — WEATHER PROTECTION
Section R904 — MATERIALS
264 Section R905 — REQUIREMENTS FOR ROOF COVERINGS
271 Section R906 — ROOF INSULATION
Section R907 — REROOFING
273 CHAPTER 10: CHIMNEYS AND FIREPLACES
Section R1001 — MASONRY CHIMNEYS
277 Section R1002 — FACTORY-BUILT CHIMNEYS
Section R1003 — MASONRY FIREPLACES
281 Section R1004 — FACTORY-BUILT FIREPLACES
Section R1005 — EXTERIOR AIR SUPPLY
283 Part IV — Energy Conservation
CHAPTER 11: ENERGY EFFICIENCY
Section N1101 — GENERAL
293 Section N1102 — BUILDING ENVELOPE
296 Section N1103 — MECHANICAL SYSTEMS
Section N1104 — SERVICE WATER HEATING
299 Part V — Mechanical
CHAPTER 12: MECHANICAL ADMINISTRATION
Section M1201 — GENERAL
Section M1202 — EXISTING MECHANICAL SYSTEMS
301 CHAPTER 13: GENERAL MECHANICAL SYSTEM REQUIREMENTS
Section M1301 — GENERAL
Section M1302 — APPROVAL
Section M1303 — LABELING OF APPLIANCES
Section M1304 — TYPE OF FUEL
Section M1305 — APPLIANCE ACCESS
302 Section M1306 — CLEARANCES FROM COMBUSTIBLE CONSTRUCTION
Section M1307 — APPLIANCE INSTALLATION
303 Section M1308 — MECHANICAL SYSTEMS INSTALLATION
307 CHAPTER 14: HEATING AND COOLING EQUIPMENT
Section M1401 — GENERAL
Section M1402 — CENTRAL FURNACES
Section M1403 — HEAT PUMP EQUIPMENT
Section M1404 — REFRIGERATION COOLING EQUIPMENT
Section M1405 — BASEBOARD CONVECTORS
Section M1406 — RADIANT HEATING SYSTEMS
308 Section M1407 — DUCT HEATERS
Section M1408 — VENTED FLOOR FURNACES
Section M1409 — VENTED WALL FURNACES
309 Section M1410 — VENTED ROOM HEATERS
Section M1411 — REFRIGERATION COOLING EQUIPMENT
Section M1412 — ABSORPTION COOLING EQUIPMENT
310 Section M1413 — EVAPORATIVE COOLING EQUIPMENT
Section M1414 — FIREPLACE STOVES
311 CHAPTER 15: EXHAUST SYSTEMS
Section M1501 — CLOTHES DRYERS EXHAUST
Section M1502 — RANGE HOODS
Section M1503 — INSTALLATION OF MICROWAVE OVENS
Section M1504 — OVERHEAD EXHAUST HOODS
Section M1505 — EXHAUST DUCTS
313 CHAPTER 16: DUCT SYSTEMS
Section M1601 — DUCT CONSTRUCTION
315 Section M1602 — RETURN AIR
Section M1603 — SUPPLY AIR
317 CHAPTER 17: COMBUSTION AIR
Section M1701 — GENERAL
Section M1702 — ALL AIR FROM INSIDE THE BUILDING
Section M1703 — ALL AIR FROM OUTDOORS
327 CHAPTER 18: CHIMNEYS AND VENTS
Section M1801 — GENERAL
Section M1802 — VENT COMPONENTS
328 Section M1803 — CHIMNEY AND VENT CONNECTORS
329 Section M1804 — VENTS
Section M1805 — MASONRY AND FACTORY-BUILT CHIMNEYS
331 CHAPTER 19: SPECIAL FUEL-BURNING EQUIPMENT
Section M1901 — RANGES AND OVENS
Section M1902 — SAUNA HEATERS
333 CHAPTER 20: BOILERS/WATER HEATERS
Section M2001 — BOILERS
Section M2002 — OPERATING AND SAFETY CONTROLS
Section M2003 — EXPANSION TANKS
Section M2004 — WATER HEATERS USED FOR SPACE HEATING
334 Section M2005 — WATER HEATERS
Section M2006 — POOL HEATERS
335 CHAPTER 21: HYDRONIC PIPING
Section M2101 — HYDRONIC PIPING SYSTEMS INSTALLATION
Section M2102 — BASEBOARD CONVECTORS
Section M2103 — FLOOR HEATING SYSTEMS
Section M2104 — LOW TEMPERATURE PIPING
336 Section M2105 — GROUND SOURCE HEAT PUMP SYSTEM LOOP PIPING
339 CHAPTER 22: SPECIAL PIPING AND STORAGE SYSTEMS
Section M2201 — OIL TANKS
Section M2202 — OIL PIPING, FITTING AND CONNECTIONS
Section M2203 — INSTALLATION
340 Section M2204 — OIL PUMPS AND VALVES
341 CHAPTER 23: SOLAR SYSTEMS
Section M2301 — SOLAR ENERGY SYSTEMS
343 Part VI — Fuel Gas
CHAPTER 24: FUEL GAS
Section G2401 — GENERAL
Section G2402 — GENERAL
Section G2403 — GENERAL DEFINITIONS
348 Section G2404 — GENERAL
349 Section G2405 — STRUCTURAL SAFETY
Section G2406 — APPLIANCE LOCATION
Section G2407 — COMBUSTION, VENTILATION AND DILUTION AIR
353 Section G2408 — INSTALLATION
Section G2409 — CLEARANCE REDUCTION
356 Section G2410 — ELECTRICAL
Section G2411 — GENERAL
357 Section G2412 — PIPE SIZING
359 Section G2413 — PIPING MATERIALS
361 Section G2414 — PIPING SYSTEM INSTALLATION
362 Section G2415 — PIPING BENDS AND CHANGES IN DIRECTION
Section G2416 — INSPECTION, TESTING AND PURGING
364 Section G2417 — PIPING SUPPORT
Section G2418 — DRIPS AND SLOPED PIPING
Section G2419 — GAS SHUTOFF VALVES
Section G2420 — FLOW CONTROLS
365 Section G2421 — APPLIANCE CONNECTIONS
Section G2422 — CNG GAS-DISPENSING SYSTEMS
Section G2423 — PIPING SUPPORT INTERVALS
Section G2424 — GENERAL
367 Section G2425 — VENTS
Section G2426 — VENTING OF EQUIPMENT
376 Section G2427 — SIZING OF CATEGORY I APPLIANCE VENTING SYSTEMS
385 Section G2428 — DIRECT-VENT, INTEGRAL VENT, MECHANICAL VENT AND VENTILATION/EXHAUST HOOD VENTING
Section G2429 — FACTORY-BUILT CHIMNEYS
Section G2430 — GENERAL
386 Section G2431 — DECORATIVE APPLIANCES FOR INSTALLATION FIREPLACES
Section G2432 — LOG LIGHTERS
Section G2433 — VENTED DECORATIVE APPLIANCES
Section G2434 — VENTED WALL FURNACES
Section G2435 — FLOOR FURNACES
387 Section G2436 — CLOTHES DRYERS
Section G2437 — CLOTHES DRYER EXHAUST
Section G2438 — SAUNA HEATERS
388 Section G2439 — POOL AND SPA HEATERS
Section G2440 — FORCED-AIR WARM-AIR FURNACES
389 Section G2441 — CONVERSION BURNERS
Section G2442 — UNIT HEATERS
Section G2443 — UNVENTED ROOM HEATERS
Section G2444 — VENTED ROOM HEATERS
Section G2445 — COOKING APPLIANCES
390 Section G2446 — WATER HEATERS
Section G2447 — AIR CONDITIONING EQUIPMENT
Section G2448 — ILLUMINATING APPLIANCES
Section G2449 — INFRARED RADIANT HEATERS
Section G2450 — BOILERS
391 Section G2451 — CHIMNEY DAMPER OPENING AREA
393 Part VII — Plumbing
CHAPTER 25: PLUMBING ADMINISTRATION
Section P2501 — GENERAL
Section P2502 — EXISTING PLUMBING SYSTEMS
Section P2503 — INSPECTION AND TESTS
395 CHAPTER 26: GENERAL PLUMBING REQUIREMENTS
Section P2601 — GENERAL
Section P2602 — INDIVIDUAL WATER SUPPLY AND SEWAGE DISPOSAL
Section P2603 — STRUCTURAL AND PIPING PROTECTION
Section P2604 — TRENCHING AND BACKFILLING
396 Section P2605 — SUPPORT
Section P2606 — WATERPROOFING OF OPENINGS
Section P2607 — WORKMANSHIP
Section P2608 — MATERIALS EVALUATION AND LISTING
399 CHAPTER 27: PLUMBING FIXTURES
Section P2701 — FIXTURES, FAUCETS AND FIXTURE FITTINGS
Section P2702 — FIXTURE ACCESSORIES
Section P2703 — TAIL PIECES
Section P2704 — ACCESS TO CONNECTIONS
Section P2705 — INSTALLATION
Section P2706 — WASTE RECEPTORS
400 Section P2707 — DIRECTIONAL FITTINGS
Section P2708 — SHOWERS
401 Section P2709 — SHOWER RECEPTORS
Section P2710 — SHOWER WALLS
Section P2711 — LAVATORIES
Section P2712 — WATER CLOSETS
402 Section P2713 — BATHTUBS
Section P2714 — SINKS
Section P2715 — LAUNDRY TUBS
Section P2716 — FOOD-WASTE GRINDER
Section P2717 — DISHWASHING MACHINES
Section P2718 — CLOTHES WASHING MACHINE
Section P2719 — FLOOR DRAINS
Section P2720 — WHIRLPOOL BATHTUBS
Section P2721 — BIDET INSTALLATIONS
403 Section P2722 — FIXTURE FITTING
Section P2723 — MACERATING TOILET SYSTEMS
405 CHAPTER 28: WATER HEATERS
Section P2801 — GENERAL
Section P2802 — WATER HEATERS USED FOR SPACE HEATING
Section P2803 — RELIEF VALVES
407 CHAPTER 29: WATER SUPPLY AND DISTRIBUTION
Section P2901 — GENERAL
Section P2902 — PROTECTION OF POTABLE WATER SUPPLY
408 Section P2903 — WATER-SUPPLY SYSTEM
413 Section P2904 — MATERIALS, JOINTS AND CONNECTIONS
415 Section P2905 — CHANGES IN DIRECTION
Section P2906 — SUPPORT
Section P2907 — DRINKING WATER TREATMENT UNITS
417 CHAPTER 30: SANITARY DRAINAGE
Section P3001 — GENERAL
Section P3002 — MATERIALS
Section P3003 — JOINTS AND CONNECTIONS
420 Section P3004 — DETERMINING DRAINAGE FIXTURE UNITS
Section P3005 — DRAINAGE SYSTEM
423 Section P3006 — SIZING OF DRAIN PIPE OFFSETS
Section P3007 — SUMPS AND EJECTORS
Section P3008 — BACKWATER VALVES
425 CHAPTER 31: VENTS
Section P3101 — VENT SYSTEMS
Section P3102 — VENT STACKS AND STACK VENTS
Section P3103 — VENT TERMINALS
Section P3104 — VENT CONNECTIONS AND GRADES
426 Section P3105 — FIXTURE VENTS
Section P3106 — INDIVIDUAL VENT
427 Section P3107 — COMMON VENT
Section P3108 — WET VENTING
Section P3109 — WASTE STACK VENT
Section P3110 — CIRCUIT VENTING
428 Section P3111 — COMBINATION WASTE AND VENT SYSTEM
Section P3112 — ISLAND FIXTURE VENTING
Section P3113 — VENT PIPE SIZING
429 Section P3114 — AIR ADMITTANCE VALVES
437 CHAPTER 32: TRAPS
Section P3201 — FIXTURE TRAPS
439 Part VIII — Electrical
CHAPTER 33: GENERAL REQUIREMENTS
Section E3301 — GENERAL
Section E3302 — BUILDING STRUCTURE PROTECTION
Section E3303 — INSPECTION AND APPROVAL
Section E3304 — GENERAL EQUIPMENT REQUIREMENTS
440 Section E3305 — EQUIPMENT LOCATION AND CLEARANCES
442 Section E3306 — ELECTRICAL CONDUCTORS AND CONNECTIONS
Section E3307 — CONDUCTOR AND TERMINAL IDENTIFICATION
445 Chapter 34: ELECTRICAL DEFINITIONS
Section E3401 — GENERAL
449 Chapter 35: SERVICES
Section E3501 — GENERAL SERVICES
Section E3502 — SERVICE SIZE AND RATING
450 Section E3503 — SERVICE, FEEDER AND GROUNDING ELECTRODE CONDUCTOR SIZING
451 Section E3504 — OVERHEAD SERVICE-DROP AND SERVICE CONDUCTOR INSTALLATION
453 Section E3505 — SERVICE-ENTRANCE CONDUCTORS
454 Section E3505 — SERVICE EQUIPMENT—GENERAL
Section E3507 — SYSTEM GROUNDING
Section E3508 — GROUNDING ELECTRODE SYSTEM
455 Section E3509 — BONDING
456 Section E3510 — GROUNDING ELECTRODE CONDUCTORS
Section E3511 — GROUNDING ELECTRODE CONDUCTOR CONNECTION TO THE GROUNDING ELECTRODES
459 Chapter 36: BRANCH CIRCUIT AND FEEDER REQUIREMENTS
Section E3601 — GENERAL
Section E3602 — BRANCH CIRCUIT RATINGS
460 Section E3603 — REQUIRED BRANCH CIRCUITS
461 Section E3604 — FEEDER REQUIREMENTS
462 Section E3605 — CONDUCTOR SIZING AND OVERCURRENT PROTECTION
464 Section E3606 — PANELBOARDS
465 Chapter 37: WIRING METHODS
Section E3701 — GENERAL REQUIREMENTS
Section E3702 — ABOVE-GROUND INSTALLATION REQUIREMENTS
Section E3703 — UNDERGROUND INSTALLATION REQUIREMENTS
471 Chapter 38: POWER AND LIGHTING DISTRIBUTION
Section E3801 — RECEPTACLE OUTLETS
473 Section E3802 — GROUND-FAULT AND ARC-FAULT CIRCUIT-INTERRUPTER PROTECTION
Section E3803 — LIGHTING OUTLETS
Section E3804 — GENERAL INSTALLATION REQUIREMENTS
474 Section E3805 — BOXES, CONDUIT BODIES AND FITTINGS
486 Section E3806 — INSTALLATION OF BOXES, CONDUIT BODIES AND FITTINGS
488 Section E3807 — CABINETS AND PANELBOARDS
Section E3808 — GROUNDING
490 Section E3809 — FLEXIBLE CORDS
491 Chapter 39: DEVICES AND LIGHTING FIXTURES
Section E3902 — SWITCHES
Section E3902 — RECEPTACLES
492 Section E3903 — FIXTURES
494 Section E3904 — FIXTURE INSTALLATION
Section E3905 — TRACK LIGHTING
495 Chapter 40: APPLIANCE INSTALLATION
Section E4001 — GENERAL
497 Chapter 41: SWIMMING POOLS
Section E4101 — GENERAL
Section E4102 — WIRING METHODS FOR POOLS, SPAS, HOT TUBS AND HYDROMASSAGE BATHTUBS
498 Section E4103 — EQUIPMENT LOCATION AND CLEARANCES
500 Section E4104 — BONDING
501 Section E4105 — GROUNDING
502 Section E4106 — EQUIPMENT INSTALLATION
504 Section E4107 — STORABLE SWIMMING POOLS
Section E4108 — SPAS AND HOT TUBS
505 Section E4109 — HYDROMASSAGE BATHTUBS
507 Chapter 42: CLASS 2 REMOTE-CONTROL, SIGNALING AND POWER-LIMITED CIRCUITS
Section E4201 — GENERAL
Section E4202 — POWER SOURCES
Section E4203 — WIRING METHODS
508 Section E4204 — INSTALLATION REQUIREMENTS
509 Part IX — Referenced Standards
CHAPTER 43: REFERENCED STANDARDS
523 APPENDIX A (IFGS): SIZING AND CAPACITIES OF GAS PIPING
527 APPENDIX B (IFGS): SIZING OF VENTING SYSTEMS SERVING APPLIANCES…
537 APPENDIX C (IFGS): EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS
539 APPENDIX D (IFGS): RECOMMENDED PROCEDURE FOR SAFETY INSPECTION OF AN EXISTING APPLIANCE INSTALLATION
541 APPENDIX E: MANUFACTURED HOUSING USED AS DWELLINGS
Section AE101 — SCOPE
Section AE102 — APPLICATION TO EXISTING MANUFACTURED HOMES AND BUILDING SERVICE EQUIPMENT
542 Section AE201 — DEFINITIONS
Section AE301 — PERMITS
Section AE302 — APPLICATION FOR PERMIT
543 Section AE303 — PERMITS ISSUANCE
Section AE304 — FEES
544 Section AE305 — INSPECTIONS
545 Section AE306 — SPECIAL INSPECTIONS
Section AE307 — UTILITY SERVICE
Section AE401 — OCCUPANCY CLASSIFICATION
Section AE402 — LOCATION ON PROPERTY
Section AE501 — DESIGN
546 Section AE502 — FOUNDATION SYSTEMS
Section AE503 — SKIRTING AND PERIMETER ENCLOSURES
Section AE504 — STRUCTURAL ADDITIONS
Section AE505 — BUILDING SERVICE EQUIPMENT
Section AE506 — EXITS
547 Section AE507 — OCCUPANCY, FIRESAFETY AND ENERGY CONSERVATION STANDARDS
Section AE600 — SPECIAL REQUIREMENTS FOR FOUNDATION SYSTEMS
Section AE601 — FOOTINGS AND FOUNDATIONS
Section AE602 — PIER CONSTRUCTION
Section AE603 — HEIGHT OF PIERS
Section AE604 — ANCHORAGE INSTALLATIONS
548 Section AE605 — TIES, MATERIALS AND INSTALLATION
549 APPENDIX F: RADON CONTROL METHODS
Section AF10 — SCOPE
Section AF102 — DEFINITIONS
Section AF103 — REQUIREMENTS
557 APPENDIX G: SWIMMING POOLS, SPAS AND HOT TUBS
Section AG101 — GENERAL
Section AG102 — DEFINITIONS
Section AG103 — SWIMMING POOLS
Section AG104 — SPAS AND HOT TUBS
Section AG105 — BARRIER REQUIREMENTS
558 Section AG106 — ABBREVIATIONS
Section AG107 — STANDARDS
559 APPENDIX H: PATIO COVERS
Section AH101 — GENERAL
Section AH102 — DEFINITION
Section AH103 — PERMITTED USES
Section AH104 — DESIGN LOADS
Section AH105 — LIGHT AND VENTILATION/EMERGENCY EGRESS
Section AH106 — FOOTINGS
561 APPENDIX I: PRIVATE SEWAGE DISPOSAL
Section AI101 — GENERAL
563 APPENDIX J: EXISTING BUILDINGS AND STRUCTURES
Section AJ10 — PURPOSE AND INTENT
Section AJ102 — COMPLIANCE
Section AJ103 — PRELIMINARY MEETING
Section AJ104 — EVALUATION OF AN EXISTING BUILDING
564 Section AJ105 — PERMIT
Section AJ201 — DEFINITIONS
Section AJ301 — REPAIRS
565 Section AJ401 — RENOVATIONS
Section AJ501 — ALTERATIONS
566 Section AJ601 — RECONSTRUCTION
567 APPENDIX K: SOUND TRANSMISSION
Section AK101 — GENERAL
Section AK102 — AIRBORNE SOUND
Section AK103 — STRUCTURAL-BORNE SOUND
569 INDEX
A
B
570 C
571 D
E
572 F
G
573 H
I
J
K
L
574 M
N
O
P
575 R
S
576 T
577 U
V
W
578 Y
ICC International Residential Code (IRC) 2000