ICC Standard 300 2017
$21.94
ICC 300-2017: Standard for Bleachers, Folding and Telescopic Seating, and Grandstands
Published By | Publication Date | Number of Pages |
ICC | 2017 | 29 |
This ICC Standard addresses the unique concerns associated with bleacher seating. It addresses new and existing installations of all types of bleacher seating including fixed and folding bleachers intended for indoor, outdoor, temporary and permanent use. This Standard is intended to coordinate with the means of egress systems in the building codes. Features of this updated edition include: Separated criteria throughout the standard for outdoor open-air assembly seating and indoor smoke-protected assembly seating, including new definitions for each type. Revisions to load combinations to consider sway and partial loading for coordination with current industry standards. Improved provisions for stepped aisles regarding tread marking stripes and opening limitations. New requirements on addressing transitions between stepped aisles around vomitories or where the stepped aisle continues onto a stairway at the beginning or ends of an aisle. Requirements for identification tags including installation and inspection information. Criteria for a safe dispersal area where access to a public way is not provided.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | ICC 300-2017 STANDARD FOR BLEACHERS, FOLDING AND TELESCOPIC SEATING, AND GRANDSTANDS |
2 | ICC 300-2017 STANDARD FOR BLEACHERS, FOLDING AND TELESCOPIC SEATING, AND GRANDSTANDS AMERICAN NATIONAL STANDARD TITLE PAGE |
3 | COPYRIGHT |
4 | AMERICAN NATIONAL STANDARD |
6 | FOREWORD |
8 | TABLE OF CONTENTS |
10 | CHAPTER 1 APPLICATION AND ADMINISTRATION SECTION 101 GENERAL SECTION 102 APPLICABILITY SECTION 103 COMPLIANCE ALTERNATIVES SECTION 104 CONVENTIONS SECTION 105 INSPECTION SECTION 106 REFERENCED DOCUMENTS |
12 | CHAPTER 2 DEFINITIONS SECTION 201 GENERAL SECTION 202 DEFINED TERMS |
14 | CHAPTER 3 CONSTRUCTION SECTION 301 GENERAL SECTION 302 PERMITTED MATERIALS SECTION 303 STRUCTURAL DESIGN TABLE 303.2 DESIGN LOADS |
15 | EQUATION 3-1 EQUATION 3-2 EQUATION 3-3 EQUATION 3-4 EQUATION 3-5 EQUATION 3-6 EQUATION 3-7 EQUATION 3-8 SECTION 304 INTERIOR INSTALLATIONS SECTION 305 SPACES BENEATH SEATS SECTION 306 CLEAR HEIGHT SECTION 307 ROOF HEIGHT SECTION 308 ELECTRICAL SECTION 309 FIRE PROTECTION |
16 | SECTION 310 ACCESSIBILITY SECTION 311 OPEN SPACES BENEATH FOOTBOARDS AND SEATBOARDS |
18 | CHAPTER 4 EGRESS SECTION 401 GENERAL SECTION 402 TRAVEL SECTION 403 OCCUPANT LOAD SECTION 404 GENERAL MEANS OF EGRESS TABLE 404.1 MINIMUM NUMBER OF EXITS |
19 | TABLE 404.5(1) WIDTH OF AISLES AND MEANS OF EGRESS FOR INDOOR SMOKE-PROTECTED ASSEMBLY SEATING TABLE 404.5(2) WIDTH OF AISLES AND MEANS OF EGRESS FOR ASSEMBLY SEATING WITHOUT SMOKE-PROTECTION TABLE 404.5(3) WIDTH OF AISLES AND MEANS OF EGRESS FOR OPEN-AIR ASSEMBLY SEATING SECTION 405 AISLES |
20 | SECTION 406 STAIRS AND STEPPED AISLES |
21 | SECTION 407 AISLE ACCESSWAYS |
22 | TABLE 407.5 AISLE ACCESSWAYS IN SMOKE-PROTECTED OR OPEN-AIR ASSEMBLY SEATING SECTION 408 GUARDS |
23 | SECTION 409 HANDRAILS |
24 | CHAPTER 5 EXISTING BLEACHERS, FOLDING AND TELESCOPIC SEATING, AND GRANDSTANDS SECTION 501 APPLICATION AND ADMINISTRATION SECTION 502 MAINTENANCE AND REPAIRS |
25 | SECTION 503 GUARDS SECTION 504 OPEN SPACES AT FOOTBOARDS AND SEATBOARDS SECTION 505 SEATING RELOCATION |
26 | CHAPTER 6 REFERENCED STANDARDS ICC |
28 | TAKE YOUR CAREER FURTHER, FASTER WITH ICC MEMBERSHIP |
29 | INTRODUCING THE ICC ASSESSMENT CENTER, FEATURING PRONTO™ |