Shopping Cart

No products in the cart.

IECC 12:2012 Edition

$25.19

International Energy Conservation Code

Published By Publication Date Number of Pages
ICC 2012 155
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

Introduced in 1998, the IECC addresses energy efficiency on several fronts including cost savings, reduced energy usage, conservation of natural resources and the impact of energy usage on the environment. Important changes in this sixth edition include:

  • A comprehensive set of changes includes measures to improve the thermal envelope, HVAC systems and electrical systems of residential buildings up to three stories in height.
  • Commercial enhancements include required energy savings for windows, doors and skylights; thermal envelope efficiency; and increased efficiencies for installed HVAC equipment.

PDF Catalog

PDF Pages PDF Title
1 2012 INTERNATIONAL ENERGY CONSERVATION CODE®
2 2012 INTERNATIONAL ENERGY CONSERVATION CODE® IECC® TITLE PAGE
3 COPYRIGHT
4 PREFACE
8 EFFECTIVE USE OF THE INTERNATIONAL ENERGY CONSERVATION CODE
10 LEGISLATION
12 TABLE OF CONTENTS
14 IECC—COMMERCIAL PROVISIONS
TABLE OF CONTENTS
16 CHAPTER 1 [CE] SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION C101 SCOPE AND GENERAL REQUIREMENTS
17 SECTION C102 ALTERNATE MATERIALS—METHOD OF CONSTRUCTION, DESIGN OR INSULATING SYSTEMS
PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION C103 CONSTRUCTION DOCUMENTS
18 SECTION C104 INSPECTIONS
SECTION C105 VALIDITY
SECTION C106 REFERENCED STANDARDS
SECTION C107 FEES
SECTION C108 STOP WORK ORDER
19 SECTION C109 BOARD OF APPEALS
20 CHAPTER 2 [CE] DEFINITIONS
SECTION C201 GENERAL
SECTION C202 GENERAL DEFINITIONS
24 CHAPTER 3 [CE] GENERAL REQUIREMENTS
SECTION C301 CLIMATE ZONES
25 FIGURE C301.1 CLIMATE ZONES
26 TABLE C301.1 CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
27 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
28 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
29 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
30 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
31 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
32 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
33 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
34 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
35 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
36 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
37 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
38 TABLE C301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
TABLE C301.3(1) INTERNATIONAL CLIMATE ZONE DEFINITIONS
39 TABLE C301.3(2) INTERNATIONAL CLIMATE ZONE DEFINITIONS
SECTION C302 DESIGN CONDITIONS
SECTION C303 MATERIALS, SYSTEMS AND EQUIPMENT
TABLE C303.1.3(1) DEFAULT GLAZED FENESTRATION U-FACTOR
TABLE C303.1.3(2) DEFAULT DOOR U-FACTORS
40 TABLE C303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC AND VT
42 CHAPTER 4 [CE] COMMERCIAL ENERGY EFFICIENCY
SECTION C401 GENERAL
SECTION C402 BUILDING ENVELOPE REQUIREMENTS
43 TABLE C402.2.1.1 MINIMUM ROOF REFLECTANCE AND EMITTANCE OPTIONSa
44 TABLE C402.1.2 OPAQUE THERMAL ENVELOPE ASSEMBLY REQUIREMENTSa
45 TABLE C402.2 OPAQUE THERMAL ENVELOPE REQUIREMENTSa
46 EQUATION 4-1
TABLE C402.3 BUILDING ENVELOPE REQUIREMENTS: FENESTRATION
47 EQUATION 4-2
TABLE C402.3.3.1 SHGC ADJUSTMENT MULTIPLIERS
49 TABLE C402.4.3 MAXIMUM AIR INFILTRATION RATE FOR FENESTRATION ASSEMBLIES
50 SECTION C403 BUILDING MECHANICAL SYSTEMS
EQUATION 4-3
EQUATION 4-4
51 TABLE C403.2.3(1) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS
52 TABLE C403.2.3(1)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS
53 TABLE C403.2.3(2) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS
54 TABLE C403.2.3(2)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS
55 TABLE C403.2.3(3) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS
56 TABLE C403.2.3(3)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS
57 TABLE 403.2.3(4) WARM AIR FURNACES AND COMBINATION WARM AIR FURNACES/AIR-CONDITIONING UNITS, WARM AIR DUCT FURNACES AND UNIT HEATERS, MINIMUM EFFICIENCY REQUIREMENTS
58 TABLE C403.2.3(5) MINIMUM EFFICIENCY REQUIREMENTS: GAS- AND OIL-FIRED BOILERS
TABLE C403.2.3(6) MINIMUM EFFICIENCY REQUIREMENTS: CONDENSING UNITS, ELECTRICALLY OPERATED
59 TABLE C403.2.3(7) MINIMUM EFFICIENCY REQUIREMENTS: WATER CHILLING PACKAGESa
60 TABLE C403.2.3(8) MINIMUM EFFICIENCY REQUIREMENTS: HEAT REJECTION EQUIPMENT
TABLE C403.2.3(9) HEAT TRANSFER EQUIPMENT
62 TABLE C403.2.6 ENERGY RECOVERY REQUIREMENT
63 EQUATION 4-5
TABLE C403.2.8 MINIMUM PIPE INSULATION THICKNESS (thickness in inches)a
64 TABLE C403.2.10.1(1) FAN POWER LIMITATION
TABLE C403.2.10.1(2) FAN POWER LIMITATION PRESSURE DROP ADJUSTMENT
65 TABLE C403.3.1(1) ECONOMIZER REQUIREMENTS
TABLE C403.3.1(2) EQUIPMENT EFFICIENCY PERFORMANCE EXCEPTION FOR ECONOMIZERS
66 TABLE C403.3.1.1.3(1) HIGH-LIMIT SHUTOFF CONTROL OPTIONS FOR AIR ECONOMIZERS
TABLE C403.3.1.1.3(2) HIGH-LIMIT SHUTOFF CONTROL SETTING FOR AIR ECONOMIZERS
69 TABLE C403.4.7 MAXIMUM HOT GAS BYPASS CAPACITY
SECTION C404 SERVICE WATER HEATING (MANATORY)
70 TABLE C404.2 MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT
71 SECTION C405 ELECTRICAL POWER AND LIGHTING SYSTEMS (MANDATORY)
74 TABLE C405.5.2(1) INTERIOR LIGHTING POWER ALLOWANCES: BUILDING AREA METHOD
75 TABLE C405.5.2(2) INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
TABLE C405.5.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
76 TABLE C405.5.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
TABLE C405.6.2(1) EXTERIOR LIGHTING ZONES
SECTION C406 ADDITIONAL EFFICIENCY PACKAGE OPTIONS
77 TABLE C405.6.2(2) INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS
78 TABLE C406.2(1) UNITARY AIR CONDITIONERS AND CONDENSING UNITS, ELECTRICALLY OPERATED, EFFICIENCY REQUIREMENTS
TABLE C406.2(2) UNITARY AND APPLIED HEAT PUMPS, ELECTRICALLY OPERATED, EFFICIENCY REQUIREMENTS
TABLE C406.2(3) PACKAGED TERMINAL AIR CONDITIONERS AND PACKAGED TERMINALHEAT PUMPS
79 TABLE C406.2(4) WARM AIR FURNACES AND COMBINATION WARM AIR FURNACES/AIR-CONDITIONING UNITS, WARM AIR DUCT FURNACES AND UNIT HEATERS, EFFICIENCY REQUIREMENTS
TABLE C406.2(5) BOILER, EFFICIENCY REQUIREMENTS
80 TABLE C406.2(6) CHILLERS—EFFICIENCY REQUIREMENTS
81 TABLE C406.2(7) ABSORPTION CHILLERS—EFFICIENCY REQUIREMENTS
TABLE C406.3 REDUCED INTERIOR LIGHTING POWER
SECTION C407 TOTAL BUILDING PERFORMANCE
83 TABLE C407.5.1(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
84 TABLE C407.5.1(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
85 TABLE C407.5.1(2) HVAC SYSTEMS MAP
86 TABLE C407.5.1(3) SPECIFICATIONS FOR THE STANDARD REFERENCE DESIGN HVAC SYSTEM DESCRIPTIONS
87 TABLE C407.5.1(4) NUMBER OF CHILLERS
TABLE C407.5.1(5) WATER CHILLER TYPES
SECTION C408 SYSTEM COMMISSIONING
90 CHAPTER 5 REFERENCED STANDARDS
AAMA
AHAM
AHRI
91 AMCA
ANSI
ASHRAE
ASTM
92 CSA
CTI
DASMA
93 DOE
ICC
IESNA
ISO
94 NFRC
SMACNA
UL
US-FTC
WDMA
96 INDEX
104 IECC—RESIDENTIAL PROVISIONS
TABLE OF CONTENTS
106 CHAPTER 1 [RE] SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION R101 SCOPE AND GENERAL REQUIREMENTS
107 SECTION R102 ALTERNATE MATERIALS—METHOD OF CONSTRUCTION, DESIGN OR INSULATING SYSTEMS
PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION R103 CONSTRUCTION DOCUMENTS
108 SECTION R104 INSPECTIONS
SECTION R105 VALIDITY
SECTION R106 REFERENCED STANDARDS
SECTION R107 FEES
SECTION R108 STOP WORK ORDER
109 SECTION R109 BOARD OF APPEALS
110 CHAPTER 2 [RE] DEFINITIONS
SECTION R201 GENERAL
SECTION R202 GENERAL DEFINITIONS
114 CHAPTER 3 [RE] GENERAL REQUIREMENTS
SECTION R301 CLIMATE ZONES
115 FIGURE R301.1 CLIMATE ZONES
116 TABLE R301.1 CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
117 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
118 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
119 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
120 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
121 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
122 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
123 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
124 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
125 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
126 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
127 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
128 TABLE R301.1—continued CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY STATE, COUNTY AND TERRITORY
TABLE R301.3(1) INTERNATIONAL CLIMATE ZONE DEFINITIONS
129 TABLE R301.3(2) INTERNATIONAL CLIMATE ZONE DEFINITIONS
SECTION R302 DESIGN CONDITIONS
SECTION R303 MATERIALS, SYSTEMS AND EQUIPMENT
TABLE R303.1.3(1) DEFAULT GLAZED FENESTRATION U-FACTOR
TABLE R303.1.3(2) DEFAULT DOOR U-FACTORS
130 TABLE R303.1.3(3) DEFAULT GLAZED FENESTRATION SHGC AND VT
132 CHAPTER 4 [RE] RESIDENTIAL ENERGY EFFICIENCY
SECTION R401 GENERAL
SECTION R402 BUILDING THERMAL ENVELOPE
TABLE R402.1.1 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa
133 TABLE R402.1.3 EQUIVALENT U-FACTORSa
134 TABLE R402.2.6 STEEL-FRAME CEILING, WALL AND FLOOR INSULATION (R-VALUE)
135 TABLE R402.4.1.1 AIR BARRIER AND INSULATION INSTALLATION
136 SECTION R403 SYSTEMS
137 TABLE R403.4.2 MAXIMUM RUN LENGTH (feet)a
TABLE R403.5.1 MECHANICAL VENTILATION SYSTEM FAN EFFICACY
138 SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS (MANDATORY)
SECTION R405 SIMULATED PERFORMANCE ALTERNATIVE (PERFORMANCE)
140 TABLE R405.5.2(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
141 TABLE R405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
142 TABLE R405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
TABLE R405.5.2(2) DEFAULT DISTRIBUTION SYSTEM EFFICIENCIES FOR PROPOSED DESIGNSa
144 CHAPTER 5 REFERENCED STANDARDS
AAMA
ACCA
ASHRAE
ASTM
145 CSA
ICC
NFRC
US-FTC
WDMA
146 INDEX
152 ICC MEMBERSHIP BENEFITS
153 ICC EVALUATION SERVICE ICC-ES
154 MAINTAIN YOUR SUSTAINABLE BUILDING EXPERTISE WITH GREEN/ENERGY TRAINING
155 COMMITTED TO BUILDING A GREEN AND SUSTAINABLE WORLD
IECC 12
$25.19