IEEE 1653.2 2020
$43.33
IEEE Standard for Uncontrolled Traction Power Rectifiers for Substation Applications up to 1500 V DC Nominal Output
Published By | Publication Date | Number of Pages |
IEEE | 2020 | 60 |
Revision Standard – Active. The design, manufacturing, and testing unique to the application of uncontrolled semiconductor power rectifiers for direct current (dc) supplied transportation substation applications up to 1500 V dc nominal output is covered in this standard. The standard is intended to address traction power substation rectifiers that are to be provided as part of a rectifier transformer unit or that are to be provided separately. Application information and extensive definitions of related technical terms are included.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | IEEE Std 1653.2™-2020 Front cover |
2 | Title page |
4 | Important Notices and Disclaimers Concerning IEEE Standards Documents |
7 | Participants |
8 | Introduction |
9 | Contents |
11 | 1. Overview 1.1 Scope 1.2 Purpose 2. Normative references |
12 | 3. Definitions 3.1 Basic rectifier components and equipment |
13 | 3.2 Appurtenances and auxiliaries |
14 | 3.3 Semiconductor rectifier diode characteristics |
15 | 3.4 Rectifier circuit properties and terminology |
17 | 3.5 Rectifier characteristics |
19 | 3.6 Rectifier unit ratings |
20 | 4. Symbols and abbreviations 4.1 Rectifier symbols |
22 | 4.2 Rectifier protective device numbers 5. Rectifier circuits 5.1 General |
24 | 6. Service conditions 6.1 Usual service conditions 6.2 Unusual service conditions |
25 | 7. Ratings 7.1 Rating of rectifier units 7.2 Basis of rating 7.3 Standard service ratings |
28 | 7.4 Operation above rated voltage 8. Performance characteristics 8.1 Efficiency and losses |
29 | 8.2 Voltage regulation |
33 | 8.3 Power factor |
35 | 8.4 Tolerances and unbalance criteria |
36 | 8.5 Auxiliaries 9. Nameplates 10. Interphase transformers 10.1 General |
37 | 10.2 Specification information 10.3 Submittal information |
38 | 11. Test procedures 11.1 Rectifier transformer tests 11.2 Interphase transformer tests 11.3 Rectifier tests |
41 | 11.4 Rectifier unit tests |
51 | Annex A (informative) Recommended practice and design guide A.1 Harmonics from uncontrolled rectifiers A.2 Rectifier service ratings |
52 | A.3 Rectifier current unbalance A.4 Rectifier transformer unit circuit configurations |
53 | A.5 Rectifier protection |
54 | A.6 Rectifier short circuit current |
55 | Annex B (informative) Commutating reactance transformation constant and power factor specification B.1 Commutating reactance transformation constant B.2 Specification of power factor |
56 | Annex C (informative) Example of current unbalance calculation C.1 Data pertaining to the transformer rectifier unit C.2 Unbalance at 100% load under normal operating conditions |
57 | C.3 Unbalance under short circuit conditions |
59 | Annex D (informative) Bibliography |
60 | Back cover |