IEEE 1799-2022
$40.63
IEEE Recommended Practice for Quality Control Testing of External Discharges on Stator Coils, Bars, and Windings
Published By | Publication Date | Number of Pages |
IEEE | 2022 |
Revision Standard – Active. The procedure for quality control testing of external discharges on stator coils, bars, and windings of large air-cooled ac electric machines is described in this recommended practice.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | IEEE Std 1799-2022 Front Cover |
2 | Title page |
4 | Important Notices and Disclaimers Concerning IEEE Standards Documents |
8 | Participants |
10 | Introduction |
11 | Contents |
12 | 1. Overview 1.1 Scope |
13 | 1.2 Purpose 1.3 Word usage 2. Normative references |
14 | 3. Definitions, acronyms, and abbreviations 3.1 Definitions |
16 | 3.2 Acronyms and abbreviations 4. Test preparation and safety |
17 | 5. Test equipment and connections |
18 | 5.1 Sensitivity of the corona imaging instruments |
19 | 6. Quality control test of external discharges with corona-imaging instrument or blackout test |
20 | 6.1 Factory test on coils and bars 6.1.1 Sample size 6.1.1.1 General 6.1.1.2 Sample coils for global VPI stator windings |
21 | 6.1.2 Test methods 6.1.3 Test voltage on individual bars and coils |
22 | 6.1.4 Test procedure for individual bars and coils 6.1.5 Acceptance criteria |
23 | 6.1.6 Remedial actions and retest 6.2 Stator model test 6.2.1 Sample size 6.2.2 Test methods |
24 | 6.2.3 Test voltage |
25 | 6.2.4 Test procedure for a group of bars or coils in a stator model 6.2.4.1 Procedure for determining DIV and DEV 6.2.5 Acceptance criteria |
26 | 6.2.6 Remedial actions and retest |
27 | 6.3 Test on fully assembled stator windings |
28 | 6.3.1 Test setup |
29 | 6.3.1.1 Precaution for blackout test on stators 6.3.2 Test methods 6.3.3 Test voltage |
30 | 6.3.4 Test procedure on fully assembled stator windings 6.3.4.1 Test with corona-imaging Instrument |
32 | 6.3.4.2 Test using blackout method |
33 | 6.3.4.3 Procedure for determining DIV and DEV 6.3.5 Acceptance criteria 6.3.6 Remedial action 7. Data records |
34 | 7.1 How to fill the data logging tables 7.1.1 Bar or coil factory tests 7.1.2 Fully assembled stator |
39 | Annex A (informative) Theory of optical emissions from external discharges |
42 | Annex B (informative) Variability of discharge inception and extinction voltages |
43 | Annex C (informative) Example of determination of the maximum voltage for a specific winding diagram |
46 | Annex D (informative) Example of correction factor to apply to the test voltage of a stator model and global VPI stator for a machine which will operate at altitudes of more than 1000 m |
48 | Annex E (informative) Example of operating-voltage table and bar/coil identification table used during test |
50 | Annex F (informative) Bibliography |
52 | Back Cover |