JIS C 8841-1:2011
$23.40
Small solid oxide fuel cell power systems – Part 1: General rules
Published By | Publication Date | Number of Pages |
JIS | 2011-03-22 | 24 |
This Japanese Industrial Standard specifies the general rules, such as the composition, structure, method of connection to the outside of a package and inspection for stationary small solid oxide fuel cell power systems (hereafter referred to as "fuel cell systems") that are in accordance with the following a) to h).
a) Type of fuel cell Solid oxide fuel cell
b) Output Rated power transmission output of less than 10 kW
c) Output mode DC output, AC output or both outputs of DC output and AC output
d) Output voltage 220 V or less in the case of AC output
e) Operation mode Grid-connected operation, grid-independent operation or independent operation
f) Raw fuel Gaseous fuel (city gas, liquefied petroleum gas, etc.), liquid fuel (kerosene, etc.) or hydrogen
g) Operating pressure Maximum working pressure of the section where fuel gas flows shall be less than 0.1 MPa.
That of the section where liquid fuel flows shall be less than 1.0 MPa.
h) System configuration Stationary generation dedicated system or cogeneration system stored in a package