Shopping Cart

No products in the cart.

MI BuildingCode 06 2006

$59.04

Michigan Building Code

Published By Publication Date Number of Pages
MI 2006 623
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This is a fully integrated custom code based on the 2006 International Building Code.

PDF Catalog

PDF Pages PDF Title
1 2006 MICHIGAN BUILDING CODE
2 2006 MICHIGAN BUILDING CODE TITLE PAGE
3 INTRODUCTION
4 COPYRIGHT®
5 PREFACE
7 SAMPLE ORDINANCE
9 TABLE OF CONTENTS
15 CHAPTER 1 – ADMINISTRATION
SECTION 101 GENERAL
SECTION 102 APPLICABILITY
16 SECTION 103 DEPARTMENT OF BUILDING SAFETY
SECTION 104 DUTIES AND POWERS OF BUILDING OFFICIAL
17 SECTION 105 PERMITS
19 SECTION 106 CONSTRUCTION DOCUMENTS
20 SECTION 107 TEMPORARY STRUCTURES AND USES
SECTION 108 FEES
SECTION 109 INSPECTIONS
21 SECTION 110 CERTIFICATE OF OCCUPANCY
22 SECTION 111 SERVICE UTILITIES
SECTION 112 BOARD OF APPEALS
SECTION 113 VIOLATIONS
SECTION 114 STOP WORK ORDER
SECTION 115 UNSAFE STRUCTURES AND EQUIPMENT
25 CHAPTER 2 – DEFINITIONS
SECTION 201 GENERAL
SECTION 202 DEFINITIONS
37 CHAPTER 3 –
USE AND OCCUPANCY CLASSIFICATION
SECTION 301 GENERAL
SECTION 302 CLASSIFICATION
SECTION 303 ASSEMBLY GROUP A
38 SECTION 304 BUSINESS GROUP B
SECTION 305 EDUCATIONAL GROUP E
SECTION 306 FACTORY GROUP F
39 SECTION 307 HIGH-HAZARD GROUP H
41 [F] TABLE 307.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARDa, j, m, n, p
42 [F] TABLE 307.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARDa, j, m, n, p
43 [F] TABLE 307.1(2) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIAL POSING A HEALTH HAZARDa, b, c, j
47 SECTION 308 INSTITUTIONAL GROUP I
48 SECTION 309 MERCANTILE GROUP M
SECTION 310 RESIDENTIAL GROUP R
49 SECTION 311 STORAGE GROUP S
SECTION 312 UTILITY AND MISCELLANEOUS GROUP U
51 CHAPTER 4 –
SPECIAL DETAILED REQUIREMENTS BASED
ON USE AND OCCUPANCY
SECTION 401 SCOPE
SECTION 402 COVERED MALL BUILDINGS
(EQUATION 4-1)
54 SECTION 403 HIGH-RISE BUILDINGS
55 SECTION 404 ATRIUMS
56 SECTION 405 UNDERGROUND BUILDINGS
57 SECTION 406 MOTOR-VEHICLE-RELATED OCCUPANCIES
59 TABLE 406.3.5 OPEN PARKING GARAGES AREA AND HEIGHT
60 SECTION 407 GROUP I-2
62 SECTION 408 GROUP I-3
63 SECTION 409 MOTION PICTURE PROJECTION ROOMS
64 SECTION 410 STAGES AND PLATFORMS
66 SECTION 411 SPECIAL AMUSEMENT BUILDINGS
67 SECTION 412 AIRCRAFT-RELATED OCCUPANCIES
TABLE 412.1.2 HEIGHT AND AREA LIMITATIONS FOR AIRPORTTRAFFIC CONTROL TOWERS
68 SECTION 413 COMBUSTIBLE STORAGE
69 SECTION 414 HAZARDOUS MATERIALS
[F] TABLE 414.2.2 DESIGN AND NUMBER OF CONTROL AREAS
70 [F] TABLE 414.2.5(1) MAXIMUM ALLOWABLE QUANTITY PER INDOOR AND OUTDOOR CONTROL AREA IN GROUP M AND S OCCUPANCIES NONFLAMMABLE SOLIDS AND NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDSd,e,f
71 TABLE [F] 414.2.5(2) MAXIMUM ALLOWABLE QUANTITY OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAIL SALES OCCUPANCIES PER CONTROL AREAa
72 [F] TABLE 414.5.1 EXPLOSION CONTROL REQUIREMENTSa
73 SECTION 415 GROUPS H-1, H-2, H-3, H-4 AND H-5
75 [F] TABLE 415.3.1 MINIMUM SEPARATION DISTANCES FOR BUILDINGS CONTAINING EXPLOSIVE MATERIALS
76 TABLE 415.3.1—continued MINIMUM SEPARATION DISTANCES FOR BUILDINGS CONTAINING EXPLOSIVE MATERIALS
77 [F] TABLE 415.3.2 REQUIRED DETACHED STORAGE
79 [F] TABLE 415.8.2.1.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5a
84 SECTION 416 APPLICATION OF FLAMMABLE FINISHES
SECTION 417 DRYING ROOMS
85 SECTION 418 ORGANIC COATINGS
SECTION 419 GROUP I-1, R-1, R-2, R-3
SECTION 420 HYDROGEN CUTOFF ROOMS
87 CHAPTER 5 –
GENERAL BUILDING HEIGHTS AND AREAS
SECTION 501 GENERAL
SECTION 502 DEFINITIONS
SECTION 503 GENERAL HEIGHT AND AREA LIMITATIONS
SECTION 504 HEIGHT
88 TABLE 503 ALLOWABLE HEIGHT AND BUILDING AREAS Height limitations shown as stories and feet above grade plane. Area limitations as determined by the definition of “Area, building,” per story
89 SECTION 505 MEZZANINES
90 SECTION 506 AREA MODIFICATIONS
(EQUATION 5-1)
(EQUATION 5-2)
91 SECTION 507 UNLIMITED AREA BUILDINGS
92 SECTION 508 MIXED USE AND OCCUPANCY
TABLE 508.2 INCIDENTAL USE AREAS
93 TABLE 508.3.3 REQUIRED SEPARATION OF OCCUPANCIES (HOURS)
94 SECTION 509 SPECIAL PROVISIONS
97 CHAPTER 6 –
TYPES OF CONSTRUCTION
SECTION 601 GENERAL
SECTION 602 CONSTRUCTION CLASSIFICATION
98 SECTION 603 COMBUSTIBLE MATERIAL IN TYPE IAND II CONSTRUCTION
99 TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (hours)
100 TABLE 602 FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCEa, e
TABLE 602.4 WOOD MEMBER SIZE
101 CHAPTER 7 –
FIRE-RESISTANCE-RATED CONSTRUCTION
SECTION 701 GENERAL
SECTION 702 DEFINITIONS
102 SECTION 703 FIRE-RESISTANCE RATINGS AND FIRE TESTS
103 SECTION 704 EXTERIOR WALLS
104 (EQUATION 7-2)
FIGURE 704.7 EQUIVALENT OPENING FACTOR
TABLE 704.8 MAXIMUM AREA OF EXTERIOR WALL OPENINGSa
106 SECTION 705 FIRE WALLS
TABLE 705.4 FIRE WALL FIRE-RESISTANCE RATINGS
108 SECTION 706 FIRE BARRIERS
TABLE 706.3.9 FIRE-RESISTANCE RATING REQUIREMENTS FOR FIRE BARRIER ASSEMBLIES OR HORIZONTAL ASSEMBLIES BETWEEN FIRE AREAS
109 SECTION 707 SHAFT ENCLOSURES
112 SECTION 708 FIRE PARTITIONS
113 SECTION 709 SMOKE BARRIERS
SECTION 710 SMOKE PARTITIONS
114 SECTION 711 HORIZONTAL ASSEMBLIES
SECTION 712 PENETRATIONS
116 SECTION 713 FIRE-RESISTANT JOINT SYSTEMS
117 SECTION 714 FIRE-RESISTANCE RATING OF STRUCTURAL MEMBERS
118 SECTION 715 OPENING PROTECTIVES
119 TABLE 715.4 FIRE DOOR AND FIRE SHUTTER FIRE PROTECTION RATINGS
121 TABLE 715.5 FIRE WINDOW ASSEMBLY FIRE PROTECTION RATINGS
TABLE 715.5.3 LIMITING SIZES OF WIRED GLASS PANELS
122 SECTION 716 DUCTS AND AIR TRANSFER OPENINGS
TABLE 716.3.1 FIRE DAMPER RATING
125 SECTION 717 CONCEALED SPACES
127 SECTION 718 FIRE-RESISTANCE REQUIREMENTS FOR PLASTER
SECTION 719 THERMAL- AND SOUND-INSULATING MATERIALS
128 SECTION 720 PRESCRIPTIVE FIRE RESISTANCE
129 TABLE 720.1(1) MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
130 TABLE 720.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
131 TABLE 720.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
132 TABLE 720.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
133 TABLE 720.1(2) RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a,o,p
134 TABLE 720.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a,o,p
135 TABLE 720.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a,o,p
136 TABLE 720.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a,o,p
137 TABLE 720.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a,o,p
138 TABLE 720.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a,o,p
139 TABLE 720.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a,o,p
140 TABLE 720.1(3) MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa,q
141 TABLE 720.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS a,q
142 TABLE 720.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS a,q
143 TABLE 720.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa,q
144 TABLE 720.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS a,q
145 TABLE 720.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS a,q
146 TABLE 720.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS a,q
147 TABLE 720.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS a,q
148 SECTION 721 CALCULATED FIRE RESISTANCE
149 TABLE 721.2.1.1 MINIMUM EQUIVALENT THICKNESS OF CAST-IN-PLACE OR PRECAST CONCRETE WALLS, LOAD-BEARING OR NONLOAD-BEARING
(EQUATION 7-3)
FIGURE 721.2.1.2 FIRE-RESISTANCE RATINGS OF TWO-WYTHE CONCRETE WALLS
(EQUATION 7-4)
150 TABLE 721.2.1.2(1) VALUES OF Rn0.59 FOR USE IN EQUATION 7-4
TABLE 721.2.1.2(2) FIRE-RESISTANCE RATINGS BASED ON R O.59
151 FIGURE 721.2.1.3.1 CERAMIC FIBER JOINT PROTECTION
TABLE 721.2.1.4(1) MULTIPLYING FACTOR FOR FINISHES ON NONFIRE-EXPOSED SIDE OF WALL
TABLE 721.2.1.4(2) TIME ASSIGNED TO FINISH MATERIALS ON FIRE-EXPOSED SIDE OF WALL
152 TABLE 721.2.2.1 MINIMUM SLAB THICKNESS (inches)
FIGURE 721.2.2.1.2 DETERMINATION OF SLAB THICKNESS FOR SLOPING SOFFITS
(EQUATION 7-5)
FIGURE 721.2.2.1.3 SLABS WITH RIBBED OR UNDULATING SOFFITS
153 FIGURE 721.2.2.2 FIRE-RESISTANCE RATINGS FOR TWO-COURSE CONCRETE FLOORS
154 FIGURE 721.2.2.3(1) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
FIGURE 721.2.2.3(2) FIRE-RESISTANCE RATINGS FOR CONCRETE
TABLE 721.2.3(1) COVER THICKNESS FOR REINFORCED CONCRETE FLOOR OR ROOF SLABS (inches)
TABLE 721.2.3(2) COVER THICKNESS FOR PRESTRESSED CONCRETE FLOOR OR ROOF SLABS (inches)
155 TABLE 721.2.3(3) MINIMUM COVER FOR MAIN REINFORCING BARS OF REINFORCED CONCRETE BEAMS (APPLICABLE TO ALL TYPES OF STRUCTURAL CONCRETE)
TABLE 721.2.3(4) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS 8 INCHES OR GREATER IN WIDTH
TABLE 721.2.3(5) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS OF ALL WIDTHS
156 TABLE 721.2.4 MINIMUM DIMENSION OF CONCRETE COLUMNS (inches)
(EQUATION 7-6)
157 TABLE 721.3.2 MINIMUM EQUIVALENT THICKNESS (inches) OF BEARING OR NONBEARING CONCRETE MASONRY WALLSa,b,c,d
(EQUATION 7-7)
TABLE 721.3.4 MINIMUM COVER OF LONGITUDINAL REINFORCEMENT IN FIRE-RESISTANCE-RATED REINFORCED CONCRETE MASONRY LINTELS (inches)
TABLE 721.3.5 MINIMUM DIMENSION OF CONCRETE MASONRY COLUMNS (inches)
158 (EQUATION 7-8)
(EQUATION 7-9)
(EQUATION 7-10)
TABLE 721.4.1(1) FIRE-RESISTANCE PERIODS OF CLAY MASONRY WALLS
159 TABLE 721.4.1(2) FIRE-RESISTANCE RATINGS FOR BEARING STEEL FRAME BRICK VENEER WALLS OR PARTITIONS
TABLE 721.4.1(3) VALUES OF Rn
TABLE 721.4.1(4) COEFFICIENTS FOR PLASTER, pl a
TABLE 721.4.1(5) REINFORCED MASONRY LINTELS
TABLE 721.4.1(6) REINFORCED CLAY MASONRY COLUMNS
(EQUATION 7-11)
160 FIGURE 721.5.1(1) DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL COLUMNS
(EQUATION 7-12)
161 (EQUATION 7-13)
FIGURE 721.5.1(2) GYPSUM WALLBOARD PROTECTED STRUCTURAL STEEL COLUMNS WITH SHEET STEEL COLUMN COVERS
FIGURE 721.5.1(3) GYPSUM WALLBOARD PROTECTED STRUCTURAL STEEL COLUMNS WITH STEEL STUD/SCREW ATTACHMENT SYSTEM
162 (EQUATION 7-14)
FIGURE 721.5.1(4) FIRE RESISTANCE OF STRUCTURAL STEEL COLUMNS PROTECTED WITH VARIOUS THICKNESSES OF TYPE X GYPSUM WALLBOARD
FIGURE 721.5.1(5) WIDE FLANGE STRUCTURAL STEEL COLUMNS WITH SPRAY-APPLIED FIRE-RESISTANT MATERIALS
FIGURE 721.5.1(6) CONCRETE PROTECTED STRUCTURAL STEEL COLUMNSa,b
(EQUATION 7-15)
163 (EQUATION 7-16)
FIGURE 721.5.1(7) CONCRETE OR CLAY MASONRY PROTECTED STRUCTURAL STEEL COLUMNS
FIGURE 721.5.2 DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL BEAMS AND GIRDERS
164 TABLE 721.5.1(1) W/D RATIOS FOR STEEL COLUMNS
165 TABLE 721.5.1(2) PROPERTIES OF CONCRETE
TABLE 721.5.1(3) THERMAL CONDUCTIVITY OF CONCRETE OR CLAY MASONRY UNITS
166 TABLE 721.5.1(4) WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
167 TABLE 721.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
168 TABLE 721.5.1(5) FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
169 TABLE 721.5.1(5)—continued FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
170 TABLE 721.5.1(6) FIRE RESISTANCE OF CLAY MASONRY PROTECTED STEEL COLUMNS
171 TABLE 721.5.1(7) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN NORMAL-WEIGHT CONCRETEa [FIGURE 721.5.1(6)(c)]
TABLE 721.5.1(8) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN STRUCTURAL LIGHTWEIGHT CONCRETEa [FIGURE 721.5.1(6)(c)]
172 TABLE 721.5.1(9) MINIMUM COVER (inch) FOR STEEL COLUMNS IN NORMAL-WEIGHT PRECAST COVERSa [FIGURE 721.5.1(6)(a)]
TABLE 721.5.1(10) MINIMUM COVER (inch) FOR STEEL COLUMNS IN STRUCTURAL LIGHTWEIGHT PRECAST COVERSa [FIGURE 721.5.1(6)(a)]
173 (EQUATION 7-17)
174 TABLE 721.6.2(1) TIME ASSIGNED TO WALLBOARD MEMBRANESa,b,c,d
(EQUATION 7-18)
(EQUATION 7-19)
(EQUATION 7-20)
(EQUATION 7-21)
TABLE 721.6.2(2) TIME ASSIGNED FOR CONTRIBUTION OF WOOD FRAME a,b,c
TABLE 721.6.2(3) MEMBRANEa ON EXTERIOR FACE OF WOOD STUD WALLS
175 TABLE 721.6.2(4) FLOORING OR ROOFING OVER WOOD FRAMING
TABLE 721.6.2(5)TIME ASSIGNED FOR ADDITIONAL PROTECTION
FIGURE 721.6.3(1) LOAD FIGURE
176 FIGURE 721.6.3(2) EFFECTIVE LENGTH FACTORS
177 CHAPTER 8 –
INTERIOR FINISHES
SECTION 801 GENERAL
SECTION 802 DEFINITIONS
SECTION 803 WALL AND CEILING FINISHES
179 TABLE 803.5 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCYk
SECTION 804 INTERIOR FLOOR FINISH
180 SECTION 805 COMBUSTIBLE MATERIALS IN TYPES I AND II CONSTRUCTION
SECTION 806 DECORATIVE MATERIALS AND TRIM
183 CHAPTER 9 –
FIRE PROTECTION SYSTEMS
SECTION 901 GENERAL
SECTION 902 DEFINITIONS
186 SECTION 903 AUTOMATIC SPRINKLER SYSTEMS
187 [F] TABLE 903.2.4.2 GROUP H-5 SPRINKLER DESIGN CRITERIA
189 [F] TABLE 903.2.13 ADDITIONAL REQUIRED SUPPRESSION SYSTEMS
190 SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS
192 SECTION 905 STANDPIPE SYSTEMS
194 SECTION 906 PORTABLE FIRE EXTINGUISHERS
SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
201 [F] TABLE 907.9.1.3 VISIBLE AND AUDIBLE ALARMS
202 SECTION 908 EMERGENCY ALARM SYSTEMS
203 SECTION 909 SMOKE CONTROL SYSTEMS
204 (EQUATION 9-1)
205 (EQUATION 9-2)
(EQUATION 9-3)
210 SECTION 910 SMOKE AND HEAT VENTS
[F] TABLE 910.3 REQUIREMENTS FOR DRAFT CURTAINS AND SMOKE AND HEAT VENTSa
211 (EQUATION 9-4)
SECTION 911 FIRE COMMAND CENTER
212 SECTION 912 FIRE DEPARTMENT CONNECTIONS
213 CHAPTER 10 –
MEANS OF EGRESS
SECTION 1001 ADMINISTRATION
SECTION 1002 DEFINITIONS
214 SECTION 1003 GENERAL MEANS OF EGRESS
215 SECTION 1004 OCCUPANT LOAD
216 TABLE 1004.1.1 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
SECTION 1005 EGRESS WIDTH
217 TABLE 1005.1 EGRESS WIDTH PER OCCUPANT SERVED
SECTION 1006 MEANS OF EGRESS ILLUMINATION
SECTION 1007 ACCESSIBLE MEANS OF EGRESS
219 SECTION 1008 DOORS, GATES AND TURNSTILES
220 TABLE 1008.1.3.1 REVOLVING DOOR SPEEDS
224 SECTION 1009 STAIRWAYS
226 SECTION 1010 RAMPS
227 SECTION 1011 EXIT SIGNS
228 SECTION 1012 HANDRAILS
229 SECTION 1013 GUARDS
230 SECTION 1014 EXIT ACCESS
232 SECTION 1015 EXIT AND EXIT ACCESS DOORWAYS
TABLE 1015.1 SPACES WITH ONE MEANS OF EGRESS
233 SECTION 1016 EXIT ACCESS TRAVEL DISTANCE
TABLE 1016.1 EXIT ACCESS TRAVEL DISTANCEa
SECTION 1017 CORRIDORS
234 TABLE 1017.1 CORRIDOR FIRE-RESISTANCE RATING
SECTION 1018 EXITS
235 SECTION 1019 NUMBER OF EXITS AND CONTINUITY
TABLE 1019.1 MINIMUM NUMBER OF EXITS FOR OCCUPANT LOAD
TABLE 1019.2 BUILDINGS WITH ONE EXIT
SECTION 1020 VERTICAL EXIT ENCLOSURES
237 SECTION 1021 EXIT PASSAGEWAYS
SECTION 1022 HORIZONTAL EXITS
238 SECTION 1023 EXTERIOR EXIT RAMPS AND STAIRWAYS
239 SECTION 1024 EXIT DISCHARGE
240 SECTION 1025 ASSEMBLY
241 TABLE 1025.6.2 WIDTH OF AISLES FOR SMOKE-PROTECTED ASSEMBLY
243 TABLE 1025.10.1 SMOKE-PROTECTED ASSEMBLY AISLE ACCESSWAYS
244 SECTION 1026 EMERGENCY ESCAPE AND RESCUE
247 CHAPTER 11 –
ACCESSIBILITY
SECTION 1101 GENERAL
SECTION 1102 DEFINITIONS
SECTION 1103 SCOPING REQUIREMENTS
248 SECTION 1104 ACCESSIBLE ROUTE
249 SECTION 1105 ACCESSIBLE ENTRANCES
250 SECTION 1106 PARKING AND PASSENGER LOADING FACILITIES
TABLE 1106.1 ACCESSIBLE PARKING SPACES
SECTION 1107 DWELLING UNITS AND SLEEPING UNITS
252 TABLE 1107.6.1.1 ACCESSIBLE DWELLING AND SLEEPING UNITS
253 SECTION 1108 SPECIAL OCCUPANCIES
254 TABLE 1108.2.2.1 ACCESSIBLE WHEELCHAIR SPACES
TABLE 1108.2.6.1 RECEIVERS FOR ASSISTIVE LISTENING SYSTEMS
255 TABLE 1108.3 ACCESSIBLE SELF-SERVICE STORAGE FACILITIES
SECTION 1109 OTHER FEATURES AND FACILITIES
258 TABLE 1109.12.2 ACCESSIBLE CHECK-OUT AISLES
259 SECTION 1110 SIGNAGE
261 CHAPTER 12 –
INTERIOR ENVIRONMENT
SECTION 1201 GENERAL
SECTION 1202 DEFINITIONS
SECTION 1203 VENTILATION
262 SECTION 1204 TEMPERATURE CONTROL
SECTION 1205 LIGHTING
263 SECTION 1206 YARDS OR COURTS
SECTION 1207 SOUND TRANSMISSION
SECTION 1208 INTERIOR SPACE DIMENSIONS
264 SECTION 1209 ACCESS TO UNOCCUPIED SPACES
SECTION 1210 SURROUNDING MATERIALS
265 CHAPTER 13 –
ENERGY EFFICIENCY
SECTION 1301 GENERAL
267 CHAPTER 14 –
EXTERIOR WALLS
SECTION 1401 GENERAL
SECTION 1402 DEFINITIONS
SECTION 1403 PERFORMANCE REQUIREMENTS
268 SECTION 1404 MATERIALS
SECTION 1405 INSTALLATION OF WALL COVERINGS
269 TABLE 1405.2 MINIMUM THICKNESS OF WEATHER COVERINGS
272 SECTION 1406 COMBUSTIBLE MATERIALS ON THE EXTERIOR SIDE OF EXTERIOR WALLS
TABLE 1406.2.1.2 MINIMUM FIRE SEPARATION FOR COMBUSTIBLE VENEERS
273 SECTION 1407 METAL COMPOSITE MATERIALS (MCM)
275 CHAPTER 15 –
ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
SECTION 1501 GENERAL
SECTION 1502 DEFINITIONS
SECTION 1503 WEATHER PROTECTION
276 SECTION 1504 PERFORMANCE REQUIREMENTS
TABLE 1504.2.1 ROOF COVERING CLASSIFICATION USING ALTERNATIVE METHOD
277 TABLE 1504.8 MAXIMUM ALLOWABLE MEAN ROOF HEIGHT PERMITTED FOR BUILDINGS WITH GRAVEL OR STONE ON THE ROOF IN AREAS OUTSIDE A HURRICANE-PRONE REGION
SECTION 1505 FIRE CLASSIFICATION
TABLE 1505.1 MINIMUM ROOF COVERING CLASSIFICATION FOR TYPES OF CONSTRUCTION
SECTION 1506 MATERIALS
278 SECTION 1507 REQUIREMENTS FOR ROOF COVERINGS
279 TABLE 1507.2.9.2 VALLEY LINING MATERIAL
281 TABLE 1507.3.7 CLAY AND CONCRETE TILE ATTACHMENTa, b, c
282 TABLE 1507.4.3(1) METAL ROOF COVERINGS
TABLE 1507.4.3(2) MINIMUM CORROSION RESISTANCE
283 TABLE 1507.7.5 SLATE SHINGLE HEADLAP
TABLE 1507.8.4 WOOD SHINGLE MATERIAL REQUIREMENTS
TABLE 1507.8.6 WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE
284 TABLE 1507.8 WOOD SHINGLE AND SHAKE INSTALLATION
285 TABLE 1507.9.5 WOOD SHAKE MATERIAL REQUIREMENTS
TABLE 1507.9.7 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE
286 TABLE 1507.10.2 BUILT-UP ROOFING MATERIAL STANDARDS
SECTION 1508 ROOF INSULATION
287 TABLE 1508.2 MATERIAL STANDARDS FOR ROOF INSULATION
SECTION 1509 ROOFTOP STRUCTURES
288 SECTION 1510 REROOFING
289 CHAPTER 16 –
STRUCTURAL DESIGN
SECTION 1601 GENERAL
SECTION 1602 DEFINITIONS AND NOTATIONS
290 SECTION 1603 CONSTRUCTION DOCUMENTS
291 SECTION 1604 GENERAL DESIGN REQUIREMENTS
292 TABLE 1604.3 DEFLECTION LIMITSa, b,
293 TABLE 1604.5 OCCUPANCY CATEGORY OF BUILDINGS AND OTHER STRUCTURES
294 SECTION 1605 LOAD COMBINATIONS
EQUATION 16-1
EQUATION 16-2
EQUATION 16-3
EQUATION 16-4
EQUATION 16-6
EQUATION 16-7
EQUATION 16-8
EQUATION 16-9
EQUATION 16-10
EQUATION 16-11
EQUATION 16-12
EQUATION 16-13
EQUATION 16-14
EQUATION 16-15
295 EQUATION 16-16
EQUATION 16-17
EQUATION 16-18
EQUATION 16-19
EQUATION 16-20
EQUATION 16-21
EQUATION 16-22
EQUATION 16-23
SECTION 1606 DEAD LOADS
296 SECTION 1607 LIVE LOADS
TABLE 1607.6 UNIFORM AND CONCENTRATED LOADS
297 TABLE 1607.1 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS AND MINIMUM CONCENTRATED LIVE LOADSg
298 TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS AND MINIMUM CONCENTRATED LIVE LOADSg
299 EQUATION 16-24
TABLE 1607.9.1 LIVE LOAD ELEMENT FACTOR,
EQUATION 16-25
EQUATION 16-26
300 EQUATION 16-27
EQUATION 16-28
EQUATION 16-29
EQUATION 16-30
EQUATION 16-31
EQUATION 16-32
EQUATION 16-33
301 SECTION 1608 SNOW LOADS
FIGURE 1608.2 GROUND SNOW LOADS R 408.30448d
302 SECTION 1609 WIND LOADS
TABLE 1609.1.2 WIND-BORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELSa,b,c,d
303 EQUATION 16-34
TABLE 1609.3.1 EQUIVALENT BASIC WIND SPEEDSa,b,c
304 EQUATION 16-35
305 FIGURE 1609 BASIC WIND SPEED (3-SECOND GUST)
306 FIGURE 1609—continued BASIC WIND SPEED (3-SECOND GUST)
307 FIGURE 1609–continued BASIC WIND SPEED (3-SECOND GUST) WESTERN GULF OF MEXICO HURRICANE COASTLINE
308 FIGURE 1609–continued BASIC WIND SPEED (3-SECOND GUST) EASTERN GULF OF MEXICO AND SOUTHEASTERN U.S. HURRICANE COASTLINE
309 FIGURE 1609–continued BASIC WIND SPEED (3-SECOND GUST) MID AND NORTHERN ATLANTIC HURRICANE COASTLINE
310 SECTION 1610 SOIL LATERAL LOADS
TABLE 1610.1 SOIL LATERAL LOAD
SECTION 1611 RAIN LOADS
EQUATION 16-36
311 SECTION 1612 FLOOD LOADS
313 SECTION 1613 EARTHQUAKE LOADS
EQUATION 16-37
EQUATION 16-38
314 TABLE 1613.5.2 SITE CLASS DEFINITIONS
TABLE 1613.5.3 (1) VALUES OF SITE COEFFICIENT Faa
315 TABLE 1613.5.3(2) VALUES OF SITE COEFFICIENT F
EQUATION 16-39
EQUATION 16-40
EQUATION 16-41
EQUATION 16-42
EQUATION 16-43
EQUATION 16-44
316 TABLE 1613.5.5 SITE CLASSIFICATION
TABLE 1613.5.6(1) SEISMIC DESIGN CATEGORY BASED ON SHORT-PERIOD RESPONSE ACCELERATIONS
317 TABLE 1613.5.6 (2) SEISMIC DESIGN CATEGORY BASED ON 1-SECOND PERIOD RESPONSE ACCELERATION
318 FIGURE 1613.5(1) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR THE CONTERMINOUS UNITED STATES OF 0.2 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
319 FIGURE 1613.5(1)—continued MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR THE CONTERMINOUS UNITED STATES OF 0.2 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
320 FIGURE 1613.5(2) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR THE CONTERMINOUS UNITED STATES OF 1.0 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
321 FIGURE 1613.5(2)—continued MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR THE CONTERMINOUS UNITED STATES OF 1.0 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
322 FIGURE 1613.5(3) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR REGION 1 OF 0.2 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
323 FIGURE 1613.5(3)—continued MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR REGION 1 OF 0.2 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
324 FIGURE 1613.5(4) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR REGION 1 OF 1.0 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
325 FIGURE 1613.5(4)—continued MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR REGION 1 OF 1.0 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
326 FIGURE 1613.5(5) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR REGION 2 OF 0.2 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
327 FIGURE 1613.5(6) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR REGION 2 OF 1.0 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
328 FIGURE 1613.5(7) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR REGION 3 OF 0.2 SEC SPECTRAL RESPONSE ACCELERATION (5% PERCENT OF CRITICAL DAMPING), SITE CLASS
329 FIGURE 1613.5(8) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR REGION 3 OF 1.0 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
330 FIGURE 1613.5(9) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR REGION 4 OF 0.2 AND 1.0 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
331 FIGURE 1613.5(10) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR HAWAII OF 0.2 AND 1.0 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
332 FIGURE 1613.5(11) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR ALASKA OF 0.2 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
333 FIGURE 1613.5(12) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR ALASKA OF 1.0 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
334 FIGURE 1613.5(13) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR PUERTO RICO, CULEBRA, VIEQUES, ST. THOMAS, ST. JOHN AND ST. CROIX OF 0.2 AND 1.0 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
335 FIGURE 1613.5(14) MAXIMUM CONSIDERED EARTHQUAKE GROUND MOTION FOR GUAM AND TUTUILLA OF 0.2 AND 1.0 SEC SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
337 CHAPTER 17 –
STRUCTURAL TESTS AND SPECIAL INSPECTIONS
SECTION 1701 GENERAL
SECTION 1702 DEFINITIONS
338 SECTION 1703 APPROVALS
SECTION 1704 SPECIAL INSPECTIONS
340 TABLE 1704.3 REQUIRED VERIFICATION AND INSPECTION OF STEEL CONSTRUCTION
341 TABLE 1704.4 REQUIRED VERIFICATION AND INSPECTION OF CONCRETE CONSTRUCTION
343 TABLE 1704.5.1 LEVEL 1 SPECIAL INSPECTION
344 TABLE 1704.5.3 LEVEL 2 SPECIAL INSPECTION
TABLE 1704.7 REQUIRED VERIFICATION AND INSPECTION OF SOILS
345 TABLE 1704.8 REQUIRED VERIFICATION AND INSPECTION OF PILE FOUNDATIONS
TABLE 1704.9 REQUIRED VERIFICATION AND INSPECTION OF PIER FOUNDATIONS
346 SECTION 1705 STATEMENT OF SPECIAL INSPECTIONS
348 SECTION 1706 CONTRACTOR RESPONSIBILITY
SECTION 1707 SPECIAL INSPECTIONS FOR SEISMIC RESISTANCE
349 SECTION 1708 STRUCTURAL TESTING FOR SEISMIC RESISTANCE
TABLE 1708.1.2 LEVEL 1 QUALITY ASSURANCE
TABLE 1708.1.4 LEVEL 2 QUALITY ASSURANCE
350 SECTION 1709 STRUCTURAL OBSERVATIONS
SECTION 1710 DESIGN STRENGTHS OF MATERIALS
SECTION 1711 ALTERNATIVE TEST PROCEDURE
SECTION 1712 TEST SAFE LOAD
SECTION 1713 IN-SITU LOAD TESTS
351 SECTION 1714 PRECONSTRUCTION LOAD TESTS
352 SECTION 1715 MATERIAL AND TEST STANDARDS
353 CHAPTER 18 –
SOILS AND FOUNDATIONS
SECTION 1801 GENERAL
SECTION 1802 FOUNDATION AND SOILS INVESTIGATIONS
354 SECTION 1803 EXCAVATION, GRADING AND FILL
355 SECTION 1804 ALLOWABLE LOAD-BEARING VALUES OF SOILS
SECTION 1805 FOOTINGS AND FOUNDATIONS
356 TABLE 1804.2 ALLOWABLE FOUNDATION AND LATERAL PRESSURE
357 FIGURE 1805.3.1 FOUNDATION CLEARANCES FROM SLOPES
358 TABLE 1805.4.2 FOOTINGS SUPPORTING WALLS OF LIGHT-FRAME CONSTRUCTIONa
359 TABLE 1805.5(1) PLAIN MASONRY FOUNDATION WALLS
360 TABLE 1805.5(2) 8-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d 5 INCHESa
361 TABLE 1805.5(3) 10-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d 6.75 INCHESa
362 TABLE 1805.5(4) 12-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d 8.75 INCHESa
363 TABLE 1805.5(5) CONCRETE FOUNDATION WALLSb
365 EQUATION 18-1
366 EQUATION 18-2
EQUATION 18-3
367 SECTION 1806 RETAINING WALLS
SECTION 1807 DAMPPROOFING AND WATERPROOFING
368 SECTION 1808 PIER AND PILE FOUNDATIONS
373 SECTION 1809 DRIVEN PILE FOUNDATIONS
374 EQUATION 18-4
375 EQUATION 18-5
EQUATION 18-6
EQUATION 18-7
EQUATION 18-8
EQUATION 18-9
EQUATION 18-10
376 SECTION 1810 CAST-IN-PLACE CONCRETE PILE FOUNDATIONS
380 SECTION 1811 COMPOSITE PILES
SECTION 1812 PIER FOUNDATIONS
383 CHAPTER 19 –
CONCRETE
SECTION 1901 GENERAL
SECTION 1902 DEFINITIONS
SECTION 1903 SPECIFICATIONS FOR TESTS AND MATERIALS
SECTION 1904 DURABILITY REQUIREMENTS
384 TABLE 1904.2.2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH
FIGURE 1904.2.2 WEATHERING PROBABILITY MAP FOR CONCRETEa
385 SECTION 1905 CONCRETE QUALITY, MIXING AND PLACING
SECTION 1906 FORMWORK, EMBEDDED PIPES AND CONSTRUCTION JOINTS
386 SECTION 1907 DETAILS OF REINFORCEMENT
SECTION 1908 MODIFICATIONS TO ACI 318
389 SECTION 1909 STRUCTURAL PLAIN CONCRETE
390 SECTION 1910 MINIMUM SLAB PROVISIONS
SECTION 1911 ANCHORAGE TO CONCRETE—ALLOWABLE STRESS DESIGN
EQUATION 19-1
SECTION 1912 ANCHORAGE TO CONCRETE—STRENGTH DESIGN
391 TABLE 1911.2 ALLOWABLE SERVICE LOAD ON EMBEDDED BOLTS (pounds)
SECTION 1913 SHOTCRETE
392 SECTION 1914 REINFORCED GYPSUM CONCRETE
SECTION 1915 CONCRETE-FILLED PIPE COLUMNS
395 CHAPTER 20 –
ALUMINUM
SECTION 2001 GENERAL
SECTION 2002 MATERIALS
397 CHAPTER 21 –
MASONRY
SECTION 2101 GENERAL
SECTION 2102 DEFINITIONS AND NOTATIONS
401 SECTION 2103 MASONRY CONSTRUCTION MATERIALS
TABLE 2103.10 CERAMIC TILE MORTAR COMPOSITIONS
402 TABLE 2103.8 (1) MORTAR PROPORTIONS
TABLE 2103.8 (2) MORTAR PROPERTIESa
403 TABLE 2103.12 GROUT PROPORTIONS BY VOLUME FOR MASONRY CONSTRUCTION
404 SECTION 2104 CONSTRUCTION
407 SECTION 2105 QUALITY ASSURANCE
408 TABLE 2105.2.2.1.1 COMPRESSIVE STRENGTH OF CLAY MASONRY
TABLE 2105.2.2.1.2 COMPRESSIVE STRENGTH OF CONCRETE MASONRY
SECTION 2106 SEISMIC DESIGN
409 EQUATION 21-1
410 SECTION 2107 ALLOWABLE STRESS DESIGN
EQUATION 21-2
EQUATION 21-3
SECTION 2108 STRENGTH DESIGN OF MASONRY
411 SECTION 2109 EMPIRICAL DESIGN OF MASONRY
412 TABLE 2109.2.1.2 DIAPHRAGM LENGTH-TO-WIDTH RATIOS
TABLE 2109.2.3.1 ALLOWABLE STRESS GROSS CROSS-SECTIONAL AREA FOR DRY-STACKED, SURFACE-BONDED CONCRETE MASONRY WALLS
TABLE 2109.4.1 WALL LATERAL SUPPORT REQUIREMENTS
413 TABLE 2109.3.2 ALLOWABLE COMPRESSIVE STRESSES FOR EMPIRICAL DESIGN OF MASONRY
414 TABLE 2109.5.3.1 FOUNDATION WALL CONSTRUCTION
416 TABLE 2109.8.3.1 ALLOWABLE SHEAR ON BOLTS IN ADOBE MASONRY
417 SECTION 2110 GLASS UNIT MASONRY
418 FIGURE 2110.3.1 GLASS MASONRY DESIGN WIND LOAD RESISTANCE
SECTION 2111 MASONRY FIREPLACES
420 FIGURE 2111.11 ILLUSTRATION OF EXCEPTION TO FIREPLACE CLEARANCE PROVISION
421 SECTION 2112 MASONRY HEATERS
SECTION 2113 MASONRY CHIMNEYS
424 FIGURE 2113.16 FLUE SIZES FOR MASONRY CHIMNEYS
TABLE 2113.16(1) NET CROSS-SECTIONAL AREA OF ROUND FLUE SIZESa
425 TABLE 2113.16 (2) NET CROSS-SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZES
FIGURE 2113.19 ILLUSTRATION OF EXCEPTION THREE CHIMNEY CLEARANCE PROVISION
427 CHAPTER 22 –
STEEL
SECTION 2201 GENERAL
SECTION 2202 DEFINITIONS
SECTION 2203 IDENTIFICATION AND PROTECTION OF STEEL FOR STRUCTURAL PURPOSES
SECTION 2204 CONNECTIONS
SECTION 2205 STRUCTURAL STEEL
428 SECTION 2206 STEEL JOISTS
SECTION 2207 STEEL CABLE STRUCTURES
429 SECTION 2208 STEEL STORAGE RACKS
SECTION 2209 COLD-FORMED STEEL
SECTION 2210 COLD-FORMED STEEL LIGHT-FRAMED CONSTRUCTION
431 CHAPTER 23 –
WOOD
SECTION 2301 GENERAL
SECTION 2302 DEFINITIONS
432 SECTION 2303 MINIMUM STANDARDS AND QUALITY
435 SECTION 2304 GENERAL CONSTRUCTION REQUIREMENTS
436 TABLE 2304.6 MINIMUM THICKNESS OF WALL SHEATHING
437 TABLE 2304.7(1) ALLOWABLE SPANS FOR LUMBER FLOOR AND ROOF SHEATHINGa
TABLE 2304.7(2) SHEATHING LUMBER, MINIMUM GRADE REQUIREMENTS: BOARD GRADE
438 TABLE 2304.7(3) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANEL SHEATHING AND SINGLE-FLOOR GRADES CONTINUOUS OVER TWO OR MORE SPANS WITH STRENGTH AXIS PERPENDICULAR TO SUPPORTSa,b
439 TABLE 2304.7(4) ALLOWABLE SPAN FOR WOOD STRUCTURAL PANEL COMBINATION SUBFLOOR-UNDERLAYMENT (SINGLE FLOOR)a,b (Panels Continuous Over Two or More Spans and Strength Axis Perpendicular to Supports)
TABLE 2304.7(5) ALLOWABLE LOAD (PSF) FOR WOOD STRUCTURAL PANEL ROOF SHEATHING CONTINUOUS OVER TWO OR MORE SPANS AND STRENGTH AXIS PARALLEL TO SUPPORTS (Plywood Structural Panels Are Five-Ply, Five-Layer Unless Otherwise Noted)a,b
441 TABLE 2304.9.1 FASTENING SCHEDULE
442 TABLE 2304.9.1—continued FASTENING SCHEDULE
443 TABLE 2304.9.1—continued FASTENING SCHEDULE
445 SECTION 2305 GENERAL DESIGN REQUIREMENTS FOR LATERAL-FORCE-RESISTING SYSTEMS
446 EQUATION 23-1
TABLE 2305.2.2(1) en VALUES (inches) FOR USE IN CALCULATING DIAPHRAGM DEFLECTION DUE TO FASTENER SLIP (Structural I)a,
TABLE 2305.2.3 MAXIMUM DIAPHRAGM DIMENSION RATIOS HORIZONTAL AND SLOPED DIAPHRAGM
447 TABLE 2305.2.2(2) VALUES OF Gt FOR USE IN CALCULATING DEFLECTION OF WOOD STRUCTURAL PANEL SHEAR WALLS AND DIAPHRAGMS
448 EQUATION 23-2
FIGURE 2305.2.5(1) DIAPHRAGM LENGTH AND WIDTH FOR PLAN VIEW OF OPEN-FRONT BUILDING
FIGURE 2305.2.5(2) DIAPHRAGM LENGTH AND WIDTH FOR PLAN VIEW OF CANTILEVERED DIAPHRAGM
449 TABLE 2305.3.4 MAXIMUM SHEAR WALL DIMENSION RATIOS
450 FIGURE 2305.3.5 GENERAL DEFINITION OF SHEAR WALL HEIGHT, WIDTH AND HEIGHT-TO-WIDTH RATIO
451 EQUATION 23-3
EQUATION 23-4
TABLE 2305.3.8.2 SHEAR RESISTANCE ADJUSTMENT FACTOR, Co
452 SECTION 2306 ALLOWABLE STRESS DESIGN
453 TABLE 2306.1.4 ALLOWABLE LOADS FOR LUMBER DECKING
TABLE 2306.2.1 WALL STUD BENDING STRESS INCREASE FACTORS
454 TABLE 2306.3.1 ALLOWABLE SHEAR (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL DIAPHRAGMS WITH FRAMING OF DOUGLAS FIR-LARCH, OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADING
455 TABLE 2306.3.1—continued ALLOWABLE SHEAR (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL DIAPHRAGMS WITH FRAMING OF DOUGLAS FIR-LARCH, OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGh
456 TABLE 2306.3.1—continued ALLOWABLE SHEAR (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL DIAPHRAGMS WITH FRAMING OF DOUGLAS FIR-LARCH,OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGh
457 TABLE 2306.3.2 ALLOWABLE SHEAR (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL BLOCKED DIAPHRAGMS UTILIZING MULTIPLE ROWS OF FASTENERS (HIGH LOAD DIAPHRAGMS) WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGb
458 TABLE 2306.3.3 DIAGONALLY SHEATHED LUMBER DIAPHRAGM NAILING SCHEDULE
459 SECTION 2307 LOAD AND RESISTANCE FACTOR DESIGN
SECTION 2308 CONVENTIONAL LIGHT-FRAME CONSTRUCTION
460 TABLE 2306.4.1 ALLOWABLE SHEAR (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL SHEAR WALLS WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGb, h, i, j,
461 TABLE 2306.4.3 ALLOWABLE SHEAR FOR PARTICLE BOARD SHEAR WALL SHEATHINGb
TABLE 2306.4.4 ALLOWABLE SHEAR VALUES (plf) FOR WIND OR SEISMIC LOADING ON SHEAR WALLS OF FIBERBOARD SHEATHING BOARD CONSTRUCTION FOR TYPE V CONSTRUCTION ONLYa
462 TABLE 2306.4.5 ALLOWABLE SHEAR FOR WIND OR SEISMIC FORCES FOR SHEAR WALLS OF LATH AND PLASTER OR GYPSUM BOARD WOOD FRAMED WALL ASSEMBLIES
465 TABLE 2308.8(1) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential Sleeping Areas, Live Load = 30 psf, L/ = 360)
466 TABLE 2308.8(1)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential Sleeping Areas, Live Load = 30 psf, L/ = 360)
467 TABLE 2308.8(2)FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential Living Areas, Live Load = 40 psf, L/ = 360)
468 TABLE 2308.8(2)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential Living Areas, Live Load = 40 psf, L/ = 360)
469 TABLE 2308.9.1 SIZE, HEIGHT AND SPACING OF WOOD STUDS
471 FIGURE 2308.9.3 BASIC COMPONENTS OF THE LATERAL BRACING SYSTEM
472 FIGURE 2308.9.3.2 ALTERNATE BRACED WALL PANEL ADJACENT TO A DOOR OR WINDOW OPENING
473 TABLE 2308.9.3 (1) BRACED WALL PANELSa
TABLE 2308.9.3(2) EXPOSED PLYWOOD PANEL SIDING
TABLE 2308.9.3(3) WOOD STRUCTURAL PANEL WALL SHEATHINGb (Not Exposed to the Weather, Strength Axis Parallel or Perpendicular to Studs Except as Indicated Below)
474 TABLE 2308.9.3(4) ALLOWABLE SPANS FOR PARTICLEBOARD WALL SHEATHING (Not Exposed to the Weather, Long Dimension of the Panel Parallel or Perpendicular to Studs
TABLE 2308.9.3(5) HARDBOARD SIDING
475 TABLE 2308.9.5 HEADER AND GIRDER SPANSa FOR EXTERIOR BEARING WALLS (Maximum Spans for Douglas Fir-Larch, Hem-Fir, Southern Pine and Spruce-Pine-Firb and Required Number of Jack Studs)
476 TABLE 2308.9.5—continued HEADER AND GIRDER SPANSaFOR EXTERIOR BEARING WALLS (Maximum Spans for Douglas Fir-Larch, Hem-Fir, Southern Pine and Spruce-Pine-Firb and Required Number of Jack Studs)
478 TABLE 2308.9.6 HEADER AND GIRDER SPANSa FOR INTERIOR BEARING WALLS (Maximum Spans for Douglas Fir-Larch, Hem-Fir, Southern Pine and Spruce-Pine-Firb and Required Number of Jack Studs)
479 TABLE 2308.10.1 REQUIRED RATING OF APPROVED UPLIFT CONNECTORS (pounds)a
480 TABLE 2308.10.2(1) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable Attics Without Storage, Live Load = 10 pounds psf, L/ = 240)
481 TABLE 2308.10.2(1)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable Attics Without Storage, Live Load = 10 pounds psf, L/ = 240)
482 TABLE 2308.10.2(2) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable Attics With Limited Storage, Live Load = 20 pounds per square foot, L/ = 240)
483 TABLE 2308.10.2(2)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable Attics With Limited Storage, Live Load = 20 pounds per square foot, L/ = 240)
484 TABLE 2308.10.3(1) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof Live Load = 20 pounds per square foot, Ceiling Not Attached to Rafters, L/ = 180)
485 TABLE 2308.10.3(1)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof Live Load = 20 pounds per square foot, Ceiling Not Attached to Rafters, L/ = 180)
486 TABLE 2308.10.3(2) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof Live Load = 20 pounds per square foot, Ceiling Not Attached to Rafters, L/ = 240)
487 TABLE 2308.10.3(2)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof Live Load = 20 pounds per square foot, Ceiling Not Attached to Rafters, L/ = 240)
488 TABLE 2308.10.3(3) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 30 pounds per square foot, Ceiling Not Attached to Rafters, L/ = 180)
489 TABLE 2308.10.3(3)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 30 pounds per square foot, Ceiling Not Attached to Rafters, L/ = 180)
490 TABLE 2308.10.3(4) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 50 pounds per square foot, Ceiling Not Attached to Rafters, L/ = 180)
491 TABLE 2308.10.3(4)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 50 pounds per square foot, Ceiling Not Attached to Rafters, L/ = 180)
492 TABLE 2308.10.3(5) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 30 pounds per square foot, Ceiling Attached to Rafters
493 TABLE 2308.10.3(5)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES(Ground Snow Load = 30 pounds per square foot, Ceiling Attached to Rafters, L/ = 240)
494 TABLE 2308.10.3(6) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 50 pounds per square foot, Ceiling Attached to Rafters, L/ = 240)
495 TABLE 2308.10.3(6)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 50 pounds per square foot, Ceiling Attached to Rafters, L/ = 240)
496 TABLE 2308.10.4.1 RAFTER TIE CONNECTIONSg
497 TABLE 2308.10.9 ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING
498 TABLE 2308.10.9–continued ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING
499 FIGURE 2308.11.3.2 STEPPED FOOTING CONNECTION DETAILS
500 FIGURE 2308.11.3.3 OPENINGS IN HORIZONTAL DIAPHRAGMS
501 TABLE 2308.12.4 WALL BRACING IN SEISMIC DESIGN CATEGORIES D AND E (Minimum Length of Wall Bracing per each 25 Linear Feet of Braced Wall Linea)
FIGURE 2308.12.6 (1) BRACED WALL PANELS OUT OF PLANE
502 FIGURE 2308.12.6(2) BRACED WALL PANELS SUPPORTED BY CANTILEVER OR SET BACK
FIGURE 2308.12.6(3) FLOOR OR ROOF NOT SUPPORTED ON ALL EDGES
FIGURE 2308.12.6(4) ROOF OR FLOOR EXTENSION BEYOND BRACED WALL LINE
503 FIGURE 2308.12.6(5) BRACED WALL PANEL EXTENSION OVER OPENING
FIGURE 2308.12.6(6) PORTIONS OF FLOOR LEVEL OFFSET VERTICALLY
FIGURE 2308.12.6(7) BRACED WALL LINES NOT PERPENDICULAR
504 FIGURE 2308.12.6(8) OPENING LIMITATIONS FOR FLOOR AND ROOF DIAPHRAGMS
505 CHAPTER 24 –
GLASS AND GLAZING
SECTION 2401 GENERAL
SECTION 2402 DEFINITIONS
SECTION 2403 GENERAL REQUIREMENTS FOR GLASS
SECTION 2404 WIND, SNOW, SEISMIC AND DEAD LOADS ON GLASS
EQUATION 24-1
EQUATION 24-2
EQUATION 24-3
EQUATION 24-4
506 EQUATION 24-5
EQUATION 24-6
EQUATION 24-7
EQUATION 24-8
EQUATION 24-9
EQUATION 24-10
EQUATION 24-11
EQUATION 24-12
507 SECTION 2405 SLOPED GLAZING AND SKYLIGHTS
508 EQUATION 24-13
EQUATION 24-14
EQUATION 24-15
SECTION 2406 SAFETY GLAZING
TABLE 2406.1 MINIMUM CATEGORY CLASSIFICATION OF GLAZING
510 SECTION 2407 GLASS IN HANDRAILS AND GUARDS
SECTION 2408 GLAZING IN ATHLETIC FACILITIES
SECTION 2409 GLASS IN ELEVATOR HOISTWAY
511 CHAPTER 25 –
GYPSUM BOARD AND PLASTER
SECTION 2501 GENERAL
SECTION 2502 DEFINITIONS
SECTION 2503 INSPECTION
SECTION 2504 VERTICAL AND HORIZONTAL ASSEMBLIES
SECTION 2505 SHEAR WALL CONSTRUCTION
512 SECTION 2506 GYPSUM BOARD MATERIALS
TABLE 2506.2 GYPSUM BOARD MATERIALS AND ACCESSORIES
SECTION 2507 LATHING AND PLASTERING
TABLE 2507.2 LATH, PLASTERING MATERIALS AND ACCESSORIES
SECTION 2508 GYPSUM CONSTRUCTION
TABLE 2508.1 INSTALLATION OF GYPSUM CONSTRUCTION
513 TABLE 2508.5 SHEAR CAPACITY FOR HORIZONTAL WOOD FRAMED GYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES
SECTION 2509 GYPSUM BOARD IN SHOWERS AND WATER CLOSETS
514 SECTION 2510 LATHING AND FURRING FOR CEMENT PLASTER (STUCCO)
SECTION 2511 INTERIOR PLASTER
TABLE 2511.1.1 INSTALLATION OF PLASTER CONSTRUCTION
515 SECTION 2512 EXTERIOR PLASTER
TABLE 2512.6 CEMENT PLASTERSa
SECTION 2513 EXPOSED AGGREGATE PLASTER
517 CHAPTER 26 –
PLASTIC
SECTION 2601 GENERAL
SECTION 2602 DEFINITIONS
SECTION 2603 FOAM PLASTIC INSULATION
520 SECTION 2604 INTERIOR FINISH AND TRIM
FIGURE 2603.8 TERMITE INFESTATION PROBABILITY MAP
521 SECTION 2605 PLASTIC VENEER
SECTION 2606 LIGHT-TRANSMITTING PLASTICS
522 SECTION 2607 LIGHT-TRANSMITTING PLASTIC WALL PANELS
TABLE 2607.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR LIGHT-TRANSMITTING PLASTIC WALL PANELSa
523 SECTION 2608 LIGHT-TRANSMITTING PLASTIC GLAZING
SECTION 2609 LIGHT-TRANSMITTING PLASTIC ROOF PANELS
524 TABLE 2609.4 AREA LIMITATIONS FOR LIGHT-TRANSMITTING PLASTIC ROOF PANELS
SECTION 2610 LIGHT-TRANSMITTING PLASTIC SKYLIGHT GLAZING
SECTION 2611 LIGHT-TRANSMITTING PLASTIC INTERIOR SIGNS
527 CHAPTER 27 –
ELECTRICAL
SECTION 2701 GENERAL
SECTION 2702 EMERGENCY AND STANDBY POWER SYSTEMS
529 CHAPTER 28 –
MECHANICAL SYSTEMS
SECTION 2801 GENERAL
531 CHAPTER 29 –
PLUMBING SYSTEMS
SECTION 2901 GENERAL
533 CHAPTER 30 –
ELEVATORS AND CONVEYING SYSTEMS
SECTION 3001 GENERAL
SECTION 3002 HOISTWAY ENCLOSURES
SECTION 3003 EMERGENCY OPERATIONS
534 SECTION 3004 HOISTWAY VENTING
SECTION 3005 CONVEYING SYSTEMS
535 SECTION 3006 MACHINE ROOMS
537 CHAPTER 31 –
SPECIAL CONSTRUCTION
SECTION 3101 GENERAL
SECTION 3102 MEMBRANE STRUCTURES
538 SECTION 3103 TEMPORARY STRUCTURES
SECTION 3104 PEDESTRIAN WALKWAYS AND TUNNELS
539 SECTION 3105 AWNINGS AND CANOPIES
540 SECTION 3106 MARQUEES
SECTION 3107 SIGNS
SECTION 3108 RADIO AND TELEVISION TOWERS
SECTION 3109 SWIMMING POOL ENCLOSURES AND SAFETY DEVICES
543 CHAPTER 32 –
ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
SECTION 3201 GENERAL
SECTION 3202 ENCROACHMENTS
545 CHAPTER 33 –
SAFEGUARDS DURING CONSTRUCTION
SECTION 3301 GENERAL
SECTION 3302 CONSTRUCTION SAFEGUARDS
SECTION 3303 DEMOLITION
SECTION 3304 SITE WORK
SECTION 3305 SANITARY
546 SECTION 3306 PROTECTION OF PEDESTRIANS
TABLE 3306.1 PROTECTION OF PEDESTRIANS
547 SECTION 3307 PROTECTION OF ADJOINING PROPERTY
SECTION 3308 TEMPORARY USE OF STREETS, ALLEYS AND PUBLIC PROPERTY
SECTION 3309 FIRE EXTINGUISHERS
SECTION 3310 EXITS
SECTION 3311 STANDPIPES
548 SECTION 3312 AUTOMATIC SPRINKLER SYSTEM
549 CHAPTER 34 –
EXISTING STRUCTURES
SECTION 3401 GENERAL
SECTION 3402 DEFINITIONS
SECTION 3403 ADDITIONS, ALTERATIONS OR REPAIRS
550 SECTION 3404 FIRE ESCAPES
551 SECTION 3405 GLASS REPLACEMENT
SECTION 3406 CHANGE OF OCCUPANCY
SECTION 3407 HISTORIC BUILDINGS
SECTION 3408 MOVED STRUCTURES
SECTION 3409 ACCESSIBILITY FOR EXISTING BUILDINGS
552 TABLE 3409.8.5 RAMPS
553 SECTION 3410 COMPLIANCE ALTERNATIVES
554 EQUATION 34-1
555 EQUATION 34-2
EQUATION 34-3
TABLE 3410.6.3 COMPARTMENTATION VALUES
TABLE 3410.6.4 SEPARATION VALUES
556 TABLE 3410.6.5 CORRIDOR WALL VALUES
EQUATION 34-4
TABLE 3410.6.6 (1) VERTICAL OPENING PROTECTION VALUE
TABLE 3410.6.6(2) CONSTRUCTION-TYPE FACTOR
557 TABLE 3410.6.8 AUTOMATIC FIRE DETECTION VALUES
TABLE 3410.6.9 FIRE ALARM SYSTEM VALUES
TABLE 3410.6.10 SMOKE CONTROL VALUES
558 TABLE 3410.6.11 MEANS OF EGRESS VALUES
TABLE 3410.6.12 DEAD-END VALUES
559 TABLE 3410.6.14 ELEVATOR CONTROL VALUES
TABLE 3410.6.15 MEANS OF EGRESS EMERGENCY LIGHTING VALUES
TABLE 3410.6.16 MIXED OCCUPANCY VALUESa
TABLE 3410.6.17 SPRINKLER SYSTEM VALUES
560 TABLE 3410.6.18 INCIDENTAL USE AREA VALUESa
TABLE 3410.8 MANDATORY SAFETY SCORESa
561 TABLE 3410.7 SUMMARY SHEET — BUILDING CODE
TABLE 3410.9 EVALUATION FORMULASa
563 CHAPTER 35 –
REFERENCED STANDARDS
AA – ALUMINUM ASSOCIATION
AAMA – AMERICAN ARCHITECTURAL MANUFACTURERS ASSOC.
ACI – AMERICAN CONCRETE INSTITUTE
564 AF&PA – AMERICAN FOREST & PAPER ASSOC.
AHA -AMERICAN HARDWOOD ASSOC.
AISC – AMERICAN INSTITUTE OF STEEL CONSTRUCTION
AISI – AMERICAN IRON AND STEEL INSTITUTE
565 AITC – AMERICAN INSTITUTE OF TIMBER CONSTRUCTION
ALI – AUTOMOTIVE LIFT INSTITUTE
ANSI – AMERICAN NATIONAL STANDARDS INSTITUTE
566 APA – ENGINEERED WOOD ASSOC.
ASAE – AMERICAN SOCIETY OF AGRICULTURAL ENGINEERS
ASCE/SEI – AMERICAN SOCIETY OF CIVIL ENGINEERS
567 ASME – AMERICAN SOCIETY OF MECHANICAL ENGINEERS
ASTM – ASTM INTERNATIONAL
573 AWCI – THE ASSOC. OF THE WALL AND CEILING INDUSTRIES INTERNATIONAL
AWPA – AMERICAN WOOD – PRESERVERS’ ASSOC.
AWS – AMERICAN WELDING SOCIETY
574 BHMA – BUILDERS HARDWARE MANUFACTUREERS’ ASSOC.
CGSB – CANADIAN GENERAL STANDARDS BOARD
CSA – CANADIAN STANDARDS ASSOC.
CPSC – CONSUMER PRODUCT SAFETY COMMISSION
CSSB – CEDAR SHAKE AND SHINGLE BUREAU
575 DASMA – DOOR AND ACCESS SYSTEMS MANUFACTURERS
DOC – U.S. DEPARTMENT OF COMMERCE
DOL – U.S. DEPARTMENT OF LABOR
DOTn – U.S. DEPARTMENT OF TRANSPORTATION
FEMA – FEDERAL EMERGENCY MANAGEMENT AGENCY
576 FM – FACTORY MUTUAL
GA – GYPSUM ASSOC.
HPVA – HARDWOOD PLYWOOD VENEER ASSOC.
ICC- INTERNATIONAL CODE COUNCIL, INC
577 ISO – INTERNATIONAL STANDARDS ORGANIZATION
MI – MICHIGAN DEPARTMENT OF LABOR & ECONOMIC GROWTH
NAAMM – NATIONAL ASSOCIATION OF ARCHITECTURAL METAL MANUFACTURERS
NCMA – NATIONAL CONCRETE MASONRY ASSOC.
NFPA – NATIONAL FIRE PROTECTION ASSOC.
579 PCI – PRECAST PRESTRESSED CONCRETE INSTITUTE
PTI – POST-TENSIONING INSTITUTE
RMI – RACK MANUFACTURERS INSTITUTE
SJI – STEEL JOIST INSTITUTE
SPRI – SINGLE-PLY ROOFING INSTITUTE
TIA – TELECOMMUNICATIONS INDUSTRY ASSOC.
580 TMS – THE MASONRY SOCIETY
TPI -TRUSS PLATE INSTITUTE
UL – UNDERWRITERS LABORATORIES, INC
581 ULC – UNDERWRITERS LABORATORIES OF CANADA
USC – UNITED STATES CODE
WDMA – WINDOW AND DOOR MANUFACTURERS ASSOC.
WRI – WIRE REINFORCEMENT INSTITUTE, INC
583 APPENDIX F –
RODENTPROOFING
SECTION F101 GENERAL
585 APPENDIX G –
FLOOD-RESISTANT CONSTRUCTION
SECTION G101 ADMINISTRATION
SECTION G102 APPLICABILITY
SECTION G103 POWERS AND DUTIES
586 SECTION G104 PERMITS
SECTION G105 VARIANCES
587 SECTION G201 DEFINITIONS
588 SECTION G301 SUBDIVISIONS
SECTION G401 SITE IMPROVEMENT
SECTION G501 MANUFACTURED HOMES
SECTION G601 RECREATIONAL VEHICLES
589 SECTION G701 TANKS
SECTION G801 OTHER BUILDING WORK
SECTION G901 REFERENCED STANDARDS
591 APPENDIX H –
SIGNS
SECTION H101 GENERAL
SECTION H102 DEFINITIONS
SECTION H103 LOCATION
SECTION H104 IDENTIFICATION
592 SECTION H105 DESIGN AND CONSTRUCTION
SECTION H106 ELECTRICAL
SECTION H107 COMBUSTIBLE MATERIALS
SECTION H108 ANIMATED DEVICES
SECTION H109 GROUND SIGNS
593 SECTION H110 ROOF SIGNS
SECTION H111 WALL SIGNS
SECTION H112 PROJECTING SIGNS
594 SECTION H113 MARQUEE SIGNS
SECTION H114 PORTABLE SIGNS
TABLE 4-A SIZE, THICKNESS AND TYPE OF GLASS PANELS IN SIGNS
TABLE 4-B THICKNESS OF PROJECTION SIGN
SECTION H115 REFERENCED STANDARDS
595 INDEX
623 DEPARTMENT OF LABOR & ECONOMIC GROWTH BUREAU OF CONSTRUCTION CODES
MI BuildingCode 06 2006
$59.04