NFPA 253 15:2015 Edition
$80.71
NFPA 253: Standard Method of Test for Critical Radiant Flux of Floor Covering Systems Using a Radiant Heat Energy Source
Published By | Publication Date | Number of Pages |
NFPA | 2015 | 26 |
For the most accurate measurement of critical radiant flux, use the revised testing procedures outlined in NFPA 253. Advance knowledge about how materials react to fire is critical to making informed selections. NFPA 253: Standard Method of Test for Critical Radiant Flux of Floor Covering Systems Using a Radiant Heat Energy Source is referenced by NFPA 101®: Life Safety Code® and building codes as the test procedure used to determine the critical radiant flux of a material. This test method is designed to provide a basis for estimating one aspect of the fire exposure behavior of a floor covering system installed in a building corridor or exitway. Testing laboratories need to take note of a major change: This edition includes an important clarification that airflow rates should be measured before igniting the panel. Valuable Annexes discuss how to calibrate an apparatus, mounting methods, sample data logs, proper application and interpretation of results, specific safety precautions, and more. ( – See more at: http://catalog.nfpa.org/2015-NFPA-253-Standard-Method-of-Test-for-Critical-Radiant-Flux-of-Floor-Covering-Systems-Using-a-Radiant-Heat-Energy-Source-P1246.aspx#sthash.gBZeM2Fq.dpuf
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | Important Notices and Disclaimers |
3 | Additional Notices And Disclaimers |
4 | 2.1 General 2.2 NFPA Publications. (Reserved) |
7 | Chapter 1 Administration 1.1 Scope 1.2 Purpose 1.3 Application 1.4 Summary of Test Method Chapter 2 Referenced Publications 2.3 Other Publications |
8 | 2.4 References for Extracts in Mandatory Sections Chapter 3 Definitions 3.1 General 3.2 NFPA Official Definitions 3.3 General Definitions |
9 | Chapter 4 Test Apparatus 4.1 Radiant Panel Test Apparatus 4.2 Test Chamber 4.3 Radiant Heat Energy Source |
10 | 4.4 Specimen Holder 4.5 Pilot Burner |
11 | 4.6 Thermocouples 4.7 Exhaust Hood 4.8 Dummy Specimen |
12 | 4.9 Timer Chapter 5 Test Specimens 5.1 Sampling Procedure 5.2 Specimen Size and Mounting |
13 | 5.3 Specimen Conditioning Chapter 6 Radiant Heat Energy Flux Profile Standardization 6.1 Procedure |
14 | Chapter 7 Test Procedure 7.1 Pretest Heating 7.2 Sample Mounting 7.3 Ignition of Pilot Burner |
15 | 7.4 Flame Propagation of Specimen 7.5 Completion of Test 7.6 Data Collection and Recording 7.7 Removal of Specimen 7.8 Subsequent Testing 7.9 Extent of Flame Travel After a Prescribed Period Chapter 8 Calculations 8.1 General 8.2 Formulas Chapter 9 Report 9.1 Required Information Annex A Explanatory Material |
16 | Annex B Procedure for Calibration of Apparatus Annex C Sample Data Logs Annex D Commentary on Critical Radiant Flux Test |
19 | Annex E Precision and Bias |
20 | Annex F Safety Precautions Annex G Informational References |
21 | Index |