SMACNA HVACDuctSystemsInspectionGuide 2006 03E
$87.21
HVAC Duct Systems Inspection Guide, 3rd Edition
Published By | Publication Date | Number of Pages |
SMACNA | 2006 | 162 |
Contains guidelines for inspection of commercial HVAC duct systems for compliance with SMACNA/ANSI HVAC Duct Construction Standards—Metal and Flexible, (3rd Ed.) and Fibrous Glass Duct Construction Standards (7th Ed.). It reviews materials and reinforcement of duct systems, as well as assembly and supports of ducts. The Fire, Smoke and Radiation Damper Guide (5th Ed.) also summarizes installation details. Checklists are included for ductwork and fire dampers. Valuable as a study guide for the HVAC Duct Construction Standards manual and for learning inspection procedures in general. Includes soft metrics.
PDF Catalog
PDF Pages | PDF Title |
---|---|
5 | FOREWORD |
6 | FORMER TASK FORCE MEMBERS AND OTHER CONTRIBUTORS |
7 | NOTICE TO USERS OF THIS PUBLICATION |
11 | TABLE OF CONTENTS |
17 | CHAPTER 1 SCOPE 1.1 SCOPE 1.2 WHAT IS THE PURPOSE OF INSPECTION? 1.3 WHAT IS THE VALUE OF INSPECTION? 1.4 WHAT IS THE COST OF INSPECTION? 1.5 DOES THE TIMING OF INSPECTIONS AFFECT CONSTRUCTION COSTS? 1.6 WHAT RISKS ARE INVOLVED WHEN INSPECTIONS ARE NOT DONE OR ARE NOT DONE PROPERLY? |
18 | 1.7 WHAT QUALIFICATIONS ARE NEEDED BY INSPECTORS? 1.8 HOW DO I USE THIS GUIDE? 1.9 DUCT INSPECTIONS OVERVIEW |
23 | CHAPTER 2 COMPLIANCE AND QUALITY CONTROL 2.1 COMPLIANCE AND QUALITY CONTROL 2.2 CHECKLISTS |
31 | APPENDIX A FUNCTIONS OF DUCTED AIR HANDLING SYSTEMS A.1 VENTILATION AND AIR CONDITIONING A.2 CENTRAL AIR HANDLING SYSTEM A.3 DEDICATED EXHAUST SYSTEMS A.4 ROOM AIR DISTRIBUTION |
32 | A.5 ROOM PRESSURE CONTROL A.6 INFILTRATION AND EXFILTRATION A.7 CENTRAL ALARM CONTROL STATIONS A.8 TESTING AND BALANCING A.9 SYMBOLS |
34 | FIGURE A-1 SYMBOLS FOR HVAC SYSTEMS |
35 | FIGURE A-1M SYMBOLS FOR HVAC SYSTEMS (METRIC) |
36 | FIGURE A-2 SINGLE DUCT SYSTEM FIGURE A-3 TERMINAL REHEAT SYSTEM |
37 | FIGURE A-4 MULTI-ZONE SYSTEM FIGURE A-5 VARIABLE VOLUME SYSTEM |
38 | FIGURE A-6 DUCT SYSTEM EXAMPLE |
39 | FIGURE A-6M DUCT SYSTEM EXAMPLE (METRIC) |
40 | FIGURE A-7 DUCT PRESSURE CLASS DESIGNATION |
43 | APPENDIX B DUCT CONSTRUCTION MATERIALS B.1 GALVANIZED STEEL B.2 CARBON STEEL (BLACK IRON) B.3 STAINLESS STEEL B.4 ALUMINUM B.5 COPPER B.6 FIBERGLASS REINFORCED PLASTIC (FRP) |
44 | B.7 POLYVINYL CHLORIDE (PVC) B.8 POLYVINYL STEEL (PVS) B.9 CONCRETE B.10 ASBESTOS CEMENT B.11 RIGID FIBROUS GLASS B.12 GYPSUM BOARD |
45 | Table B-1 Galvanized Sheet Thickness Tolerances |
46 | Table B-2 Manufacturers Standard Gage-Thickness (Uncoated Steel) |
47 | Table B-3 Stainless Steel Sheet Thickness |
48 | Table B-4 Aluminum Sheet Thickness (Alloy 3003-H14)) |
51 | APPENDIX C HVAC DUCT CONSTRUCTION STANDARDS C.1 DUCT CONSTRUCTION AND INSTALLATION STANDARDS |
52 | C.2 DUCT SEALING COMMENTARY Table C-1 Standard Duct Sealing Requirements |
55 | C.3 RECTANGULAR DUCT REINFORCEMENT |
57 | FIGURE C-1 DEPENDENT VARIABLES |
58 | C.4 INTRODUCTION TO THE RECTANGULAR DUCT CONSTRUCTION SCHEDULES |
59 | FIGURE C-2 READING GUIDE SUMMARY |
64 | Table C-2 Rectangular Duct Reinforcement |
65 | Table C-2M Rectangular Duct Reinforcement |
66 | FIGURE C-3 UNREINFORCED DUCT |
68 | Table C-3 Unreinforced Duct (Wall Thickness) |
69 | Table C-3M Unreinforced Duct (Wall Thickness) |
70 | FIGURE C-4 CROSSBROKEN AND BEADED DUCT |
71 | FIGURE C-5 FLEXIBLE DUCT LINER INSTALLATION |
72 | FIGURE C-6 LINER FASTENERS |
73 | FIGURE C-7 DUCT REINFORCED ON TWO SIDES |
74 | FIGURE C-8 REINFORCEMENT ATTACHMENT |
75 | C.5 TRANSVERSE JOINTS FOR RECTANGULAR DUCT |
76 | FIGURE C-9 RECTANGULAR DUCT/TRANSVERSE JOINTS |
77 | FIGURE C-9 RECTANGULAR DUCT/TRANSVERSE JOINTS (CONTINUED) |
78 | FIGURE C-9 RECTANGULAR DUCT/TRANSVERSE JOINTS (CONTINUED) |
79 | FIGURE C-9 RECTANGULAR DUCT/TRANSVERSE JOINTS (CONTINUED) |
80 | Table C-4 Intermediate Reinforcement |
81 | Table C-4M Intermediate Reinforcement |
82 | Table C-5 Transverse Joint Reinforcement |
83 | Table C-5M Transverse Joint Reinforcement |
84 | Table C-6 Transverse Joint Reinforcement |
85 | Table C-6M Transverse Joint Reinforcement |
86 | FIGURE C-10 RECTANGULAR DUCT/LONGITUDINAL SEAMS |
87 | FIGURE C-11 RECTANGULAR ELBOWS |
88 | FIGURE C-11 RECTANGULAR ELBOWS (CONTINUED) |
89 | FIGURE C-12 VANES AND VANE RUNNERS |
90 | FIGURE C-13 VANE SUPPORT IN ELBOWS |
91 | FIGURE C-14 BRANCH CONNECTION |
92 | C.6 VOLUME DAMPERS (NOTES FOR FIGURES C-15 AND C-16) C.7 COMMENTARY |
93 | FIGURE C-15 VOLUME DAMPERS – SINGLE BLADE TYPE |
94 | FIGURE C-16 MULTIBLADE VOLUME DAMPERS |
95 | FIGURE C-17 OFFSETS AND TRANSITIONS |
96 | FIGURE C-18 REMOTE HEATING AND COOLING COIL INSTALLATIONS |
97 | FIGURE C-19 CEILING DIFFUSER BRANCH DUCTS |
98 | C.8 SPECIFICATION FOR SUPPORTING FLEXIBLE DUCT |
99 | FIGURE C-20 FLEXIBLE DUCT SUPPORTS |
100 | FIGURE C-21 FLEXIBLE DUCT SUPPORTS |
101 | C.9 ROUND DUCT CONSTRUCTION STANDARDS C.10 COMMENTARY |
102 | Table C-7 Mitered Elbows |
104 | Table C-8 Round Duct Gage Unreinforced Positive Pressure |
105 | Table C-8M Round Duct Gage Unreinforced Positive Pressure |
106 | FIGURE C-22 ROUND DUCT TRANSVERSE JOINTS |
107 | FIGURE C-22 ROUND DUCT TRANSVERSE JOINTS (CONTINUED) |
108 | FIGURE C-23 ROUND DUCT LONGITUDINAL SEAMS |
109 | FIGURE C-24 HANGER ATTACHMENTS TO STRUCTURES |
110 | FIGURE C-25 UPPER ATTACHMENT DEVICES – TYPICAL |
111 | FIGURE C-26 LOWER HANGER ATTACHMENTS |
112 | Table C-9 Rectangular Duct Hangers Minimum Size |
113 | Table C-9M Rectangular Duct Hangers Minimum Size |
114 | Table C-10 Minimum Hanger Sizes for Round Duct |
116 | FIGURE C-27 RISER SUPPORTS – FROM FLOOR |
117 | FIGURE C-27M RISER SUPPORTS – FROM FLOOR |
118 | FIGURE C-28 ROOFTOP DUCT INSTALLATION |
119 | FIGURE C-29 EQUIPMENT AND DUCT SUPPORT FLASHING |
120 | FIGURE C-30 RECTANGULAR GOOSENECK |
121 | C.11 CASING AND PLENUM CONSTRUCTION STANDARDS |
122 | FIGURE C-31 BUILT-UP STANDING SEAM CASING |
123 | FIGURE C-32 DISHWASHER VAPOR EXHAUST |
127 | APPENDIX D FIRE, SMOKE, AND RADIATION DAMPER GUIDE Table D-1 Recommended Fire Damper Installation Instructions |
128 | FIGURE D-1 BASIC FIRE DAMPER INSTALLATION DETAILS |
129 | Table D-2 Recommended Minimum Sleeve Thickness for Fire Dampers* |
130 | FIGURE D-2 UL DUCT-SLEEVE CONNECTIONS (BREAKAWAY CONNECTIONS) |
131 | FIGURE D-2 UL DUCT-SLEEVE CONNECTIONS (BREAKAWAY CONNECTIONS) (CONTINUED) |
132 | FIGURE D-3 FIRE DAMPER OPENING PROTECTION |
133 | FIGURE D-4 CURTAIN FIRE DAMPERS |
134 | FIGURE D-5 COMBINATION FIRE AND SMOKE DAMPERS |
135 | FIGURE D-6 DUCT LINER INTERRUPTION |
136 | FIGURE D-7 ACCESS DOORS AND PANELS |
137 | FIGURE D-8 LEAKAGE RATED (SMOKE) DAMPER |
138 | FIGURE D-9 FIRE RATED CEILING ASSEMBLIES |
141 | APPENDIX E FIBROUS GLASS DUCT CONSTRUCTION E.1 FIBROUS GLASS DUCT CHARACTERISTICS AND LIMITATIONS |
142 | E.2 CLOSURES |
143 | FIGURE E-1 TAPE CLOSURE JOINT, WITH STAPLE FLAP FIGURE E-2 TAPE CLOSURE JOINT, WITHOUT STAPLE FLAP |
144 | FIGURE E-3 CLOSURES (CONTINUED) |
145 | E.3 ADDITIONAL FIBROUS GLASS DUCT CONSTRUCTION DETAILS FIGURE E-4 TIE ROD REINFORCEMENT AT JOINT |
146 | FIGURE E-5 SHEET METAL AND EQUIPMENT CONNECTION DETAILS |
147 | FIGURE E-6 SHEET METAL AND EQUIPMENT CONNECTION DETAILS (CONTINUED) |
148 | Table E-1 Tie Rod System Reinforcement Schedule FIGURE E-7 TIE ROD REINFORCEMENT |
149 | Table E-1M Tie Rod System Reinforcement Schedule FIGURE E-7M TIE ROD REINFORCEMENT |
150 | FIGURE E-8 TIE ROD TERMINATION METHODS |
152 | Table E-2 Channel System Reinforcement Schedule |
153 | Table E-2M Channel System Reinforcement Schedule |
154 | FIGURE E-9 CHANNEL REINFORCEMENT, POSITIVE PRESSURE SYSTEMS |
155 | FIGURE E-10 CHANNEL REINFORCEMENT, NEGATIVE PRESSURE SYSTEMS |
156 | Table E-3 Partial Wrap-around Reinforcement Schedule FIGURE E-11 PARTIAL WRAP-AROUND REINFORCEMENT |
157 | Table E-3M Partial Wrap-around Reinforcement Schedule FIGURE E-11M PARTIAL WRAP-AROUND REINFORCEMENT |
158 | FIGURE E-12 ALLOWABLE HANGER SPACING, STRAIGHT DUCT ” 3 INCH WIDE CHANNELS |
159 | Table E-4 Maximum Hanger Spacing by Duct Size, I.D. Table E-5 Channel Selection FIGURE E-13 HANGER SPACING AND EXTENSION ” 3 INCH WIDE CHANNELS FIGURE E-14 USE OF 2 INCH WIDE HANGER CHANNELS |
160 | FIGURE E-15 ACCESS DOOR, FLANGE ON OPENING |