Shopping Cart

No products in the cart.

VA VAPC 2009

$43.33

Virginia Plumbing Code

Published By Publication Date Number of Pages
VA 2009 173
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This is a fully integrated code based on the 2009 International Plumbing Code®.

PDF Catalog

PDF Pages PDF Title
1 2009 VIRGINIA PLUMBING CODE
2 2009 VIRGINIA PLUMBING CODE EXCERPTS FROM THE VIRGINIA CONSTRUCTION CODE FOR PLUMBING WORK TITLE PAGE
3 COPYRIGHT
4 PREFACE
6 TABLE OF CONTENTS
10 CHAPTER 1 – ADMINISTRATION
SECTION 101 GENERAL
SECTION 102 PURPOSE AND SCOPE
SECTION 103 APPLICATION OF CODE
12 SECTION 104 ENFORCEMENT, GENERALLY
13 SECTION 105 LOCAL BUILDING DEPARTMENT
14 SECTION 106 POWERS AND DUTIES OF THE BUILDING OFFICIAL
SECTION 107 FEES
SECTION 108 APPLICATION FOR PERMIT
16 SECTION 109 CONSTRUCTION DOCUMENTS
17 SECTION 110 PERMITS
18 SECTION 111 RDP SERVICES
SECTION 112 WORKMANSHIP, MATERIALS AND EQUIPMENT
19 SECTION 113 INSPECTIONS
20 SECTION 114 STOP WORK ORDERS
SECTION 115 VIOLATIONS
21 SECTION 116 CERTIFICATES OF OCCUPANCY
SECTION 117 TEMPORARY AND MOVED BUILDINGS AND STRUCTURES; DEMOLITION
22 SECTION 118 BUILDINGS AND STRUCTURES BECOMING UNSAFE DURING CONSTRUCTION
SECTION 119 APPEALS
26 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS
34 CHAPTER 3 – GENERAL REGULATIONS
SECTION 301 GENERAL
SECTION 302 EXCLUSION OF MATERIALS DETRIMENTAL TO THE SEWER SYSTEM
SECTION 303 MATERIALS
SECTION 304 RODENTPROOFING
35 TABLE 303.4 PRODUCTS AND MATERIALS REQUIRING THIRD-PARTY TESTING AND THIRD-PARTY CERTIFICATION
SECTION 305 PROTECTION OF PIPES AND PLUMBING SYSTEM COMPONENTS
SECTION 306 TRENCHING, EXCAVATION AND BACKFILL
36 SECTION 307 STRUCTURAL SAFETY
SECTION 308 PIPING SUPPORT
37 TABLE 308.5 HANGER SPACING
SECTION 309 FLOOD HAZARD RESISTANCE
SECTION 310 WASHROOM AND TOILET ROOM REQUIREMENTS
38 SECTION 311 TOILET FACILITIES FOR WORKERS
SECTION 312 TESTS AND INSPECTIONS
39 SECTION 313 EQUIPMENT EFFICIENCIES
SECTION 314 CONDENSATE DISPOSAL
TABLE [M] 314.2.2 CONDENSATE DRAIN SIZING
42 CHAPTER 4 – FIXTURES, FAUCETS AND FIXTURE FITTINGS
SECTION 401 GENERAL
SECTION 402 FIXTURE MATERIALS
SECTION 403 MINIMUM PLUMBING FACILITIES
TABLE 403.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES
43 TABLE 403.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES
44 TABLE 403.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES
45 SECTION 404 ACCESSIBLE PLUMBING FACILITIES
SECTION 405 INSTALLATION OF FIXTURES
46 FIGURE 405.3.1 FIXTURE CLEARANCE
SECTION 406 AUTOMATIC CLOTHES WASHERS
47 SECTION 407 BATHTUBS
SECTION 408 BIDETS
SECTION 409 DISHWASHING MACHINES
SECTION 410 DRINKING FOUNTAINS
SECTION 411 EMERGENCY SHOWERS AND EYEWASH STATIONS
SECTION 412 FLOOR AND TRENCH DRAINS
SECTION 413 FOOD WASTE GRINDER UNITS
SECTION 414 GARBAGE CAN WASHERS
48 SECTION 415 LAUNDRY TRAYS
SECTION 416 LAVATORIES
SECTION 417 SHOWERS
49 SECTION 418 SINKS
SECTION 419 URINALS
SECTION 420 WATER CLOSETS
50 SECTION 421 WHIRLPOOL BATHTUBS
SECTION 422 HEALTH CARE FIXTURES AND EQUIPMENT
51 SECTION 423 SPECIALTY PLUMBING FIXTURES
SECTION 424 FAUCETS AND OTHER FIXTURE FITTINGS
SECTION 425 FLUSHING DEVICES FOR WATER CLOSETS AND URINALS
52 SECTION 426 MANUAL FOOD AND BEVERAGE DISPENSING EQUIPMENT
SECTION 427 FLOOR SINKS
54 CHAPTER 5 – WATER HEATERS
SECTION 501 GENERAL
SECTION 502 INSTALLATION
SECTION 503 CONNECTIONS
55 SECTION 504 SAFETY DEVICES
SECTION 505 INSULATION
56 CHAPTER 6 – WATER SUPPLY AND DISTRIBUTION
SECTION 601 GENERAL
SECTION 602 WATER REQUIRED
SECTION 603 WATER SERVICE
57 SECTION 604 DESIGN OF BUILDING WATER DISTRIBUTION SYSTEM
TABLE 604.3 WATER DISTRIBUTION SYSTEM DESIGN CRITERIA REQUIRED CAPACITY AT FIXTURE SUPPLY PIPE OUTLETS
TABLE 604.4 MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGS
58 TABLE 604.5 MINIMUM SIZES OF FIXTURE WATER SUPPLY PIPES
TABLE 604.10.1 MANIFOLD SIZING
SECTION 605 MATERIALS, JOINTS AND CONNECTIONS
59 TABLE 605.3 WATER SERVICE PIPE
60 TABLE 605.4 WATER DISTRIBUTION PIPE
TABLE 605.5 PIPE FITTINGS
61 TABLE 605.8 MANUFACTURED PIPE NIPPLES
63 SECTION 606 INSTALLATION OF THE BUILDING WATER DISTRIBUTION SYSTEM
64 TABLE 606.5.4 SIZES FOR OVERFLOW PIPES FOR WATER SUPPLY TANKS
TABLE 606.5.7 SIZE OF DRAIN PIPES FOR WATER TANKS
SECTION 607 HOT WATER SUPPLY SYSTEM
65 SECTION 608 PROTECTION OF POTABLE WATER SUPPLY
66 TABLE 608. 1 APPLICATION OF BACKFLOW PREVENTERS
67 TABLE 608.8.3 SIZE OF PIPE IDENTIFICATION
68 TABLE 608.15.1 MINIMUM REQUIRED AIR GAPS
69 TABLE 608.17.1 DISTANCE FROM CONTAMINATION TO PRIVATE WATER SUPPLIES AND PUMP SUCTION LINES
70 SECTION 609 HEALTH CARE PLUMBING
SECTION 610 DISINFECTION OF POTABLE WATER SYSTEM
SECTION 611 DRINKING WATER TREATMENT UNITS
71 SECTION 612 SOLAR SYSTEMS
SECTION 613 TEMPERATURE CONTROL DEVICES AND VALVES
72 CHAPTER 7 – SANITARY DRAINAGE
SECTION 701 GENERAL
SECTION 702 MATERIALS
TABLE 702.1 ABOVE-GROUND DRAINAGE AND VENT PIPE
73 TABLE 702.2 UNDERGROUND BUILDING DRAINAGE AND VENT PIPE
TABLE 702.3 BUILDING SEWER PIPE
74 TABLE 702.4 PIPE FITTINGS
SECTION 703 BUILDING SEWER
SECTION 704 DRAINAGE PIPING INSTALLATION
TABLE 704.1 SLOPE OF HORIZONTAL DRAINAGE PIPE
75 SECTION 705 JOINTS
77 TABLE 705.21 CAULKING FERRULE SPECIFICATIONS
TABLE 705.22 SOLDERING BUSHING SPECIFICATIONS
SECTION 706 CONNECTIONS BETWEEN DRAINAGE PIPING AND FITTINGS
78 TABLE 706.3 FITTINGS FOR CHANGE IN DIRECTION
SECTION 707 PROHIBITED JOINTS AND CONNECTIONS
SECTION 708 CLEANOUTS
79 SECTION 709 FIXTURE UNITS
TABLE 709.2 DRAINAGE FIXTURE UNITS FOR FIXTURE DRAINS OR TRAPS
SECTION 710 DRAINAGE SYSTEM SIZING
80 TABLE 709.1 DRAINAGE FIXTURE UNITS FOR FIXTURES AND GROUPS
81 TABLE 710.1(1) BUILDING DRAINS AND SEWERS
TABLE 710.1(2) HORIZONTAL FIXTURE BRANCHES AND STACKS
82 SECTION 711 OFFSETS IN DRAINAGE PIPING IN BUILDINGS OF FIVE STORIES OR MORE
SECTION 712 SUMPS AND EJECTORS
83 TABLE 712.4.2 MINIMUM CAPACITY OF SEWAGE PUMP OR SEWAGE EJECT OR
SECTION 713 HEALTH CARE PLUMBING
84 TABLE 713.11.1 STACK SIZES FOR BEDPAN STEAMERS AND BOILING-TYPE STERILIZERS
TABLE 713.11.3 STACK SIZES FOR PRESSURE STERILIZERS
SECTION 714 COMPUTERIZED DRAINAGE DESIGN
SECTION 715 BACKWATER VALVES
86 CHAPTER 8 – INDIRECT/SPECIAL WASTE
SECTION 801 GENERAL
SECTION 802 INDIRECT WASTES
87 SECTION 803 SPECIAL WASTES
SECTION 804 MATERIALS, JOINTS AND CONNECTIONS
88 CHAPTER 9 – VENTS
SECTION 901 GENERAL
SECTION 902 MATERIALS
SECTION 903 OUTDOOR VENT EXTENSION
SECTION 904 VENT TERMINALS
89 SECTION 905 VENT CONNECTIONS AND GRADES
SECTION 906 FIXTURE VENTS
TABLE 906.1 MAXIMUM DISTANCE OF FIXTURE TRAP FROM VENT
SECTION 907 INDIVIDUAL VENT
SECTION 908 COMMON VENT
TABLE 908.3 COMMON VENT SIZES
90 SECTION 909 WET VENTING
TABLE 909.3 WET VENT SIZE
SECTION 910 WASTE STACK VENT
TABLE 910.4 WASTE STACK VENT SIZE
SECTION 911 CIRCUIT VENTING
91 SECTION 912 COMBINATION DRAIN AND VENT SYSTEM
TABLE 912.3 SIZE OF COMBINATION DRAIN AND VENT PIPE
SECTION 913 ISLAND FIXTURE VENTING
92 SECTION 914 RELIEF VENTS—STACKS OF MORE THAN 10 BRANCH INTERVALS
SECTION 915 VENTS FOR STACK OFFSETS
SECTION 916 VENT PIPE SIZING
TABLE 916.1 SIZE AND DEVELOPED LENGTH OF STACK VENTS AND VENT STACKS
93 TABLE 916.1—continued SIZE AND DEVELOPED LENGTH OF STACK VENTS AND VENT STACKS
SECTION 917 AIR ADMITTANCE VALVES
94 TABLE 916.5.1 SIZE AND LENGTH OF SUMP VENTS
SECTION 918 ENGINEERED VENT SYSTEMS
95 EQUATION 9-1
TABLE 918.2 MINIMUM DIAMETER AND MAXIMUM LENGTH OF INDIVIDUAL BRANCH FIXTURE VENTS AND INDIVIDUAL FIXTURE HEADER VENTS FOR SMOOTH PIPES
SECTION 919 COMPUTERIZED VENT DESIGN
96 CHAPTER 10 TRAPS, INTERCEPTORS AND SEPARATORS
SECTION 1001 GENERAL
SECTION 1002 TRAP REQUIREMENTS
SECTION 1003 INTERCEPTORS AND SEPARATORS
97 TABLE 1003.3.4.1 CAPACITY OF GREASE INTERCEPTORS
98 SECTION 1004 MATERIALS, JOINTS AND CONNECTIONS
100 CHAPTER 11 – STORM DRAINAGE
SECTION 1101 GENERAL
SECTION 1102 MATERIALS
TABLE 1102.4 BUILDING STORM SEWER PIPE
TABLE 1102.5 SUBSOIL DRAIN PIPE
101 TABLE 1102.7 PIPE FITTINGS
SECTION 1103 TRAPS
SECTION 1104 CONDUCTORS AND CONNECTIONS
SECTION 1105 ROOF DRAINS
SECTION 1106 SIZE OF CONDUCTORS, LEADERS AND STORM DRAINS
102 FIGURE 1106.1100-YEAR, 1-HOUR RAINFALL (INCHES) EASTERN UNITED STATES
103 FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) CENTRAL UNITED STATES
104 FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) WESTERN UNITED STATES
105 FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) ALASKA
106 FIGURE 1106.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) HAWAII
107 TABLE 1106.2(1) SIZE OF CIRCULAR VERTICAL CONDUCTORS AND LEADERS
TABLE 1106.2(2) SIZE OF RECTANGULAR VERTICAL CONDUCTORS AND LEADERS
108 TABLE 1106.3 SIZE OF HORIZONTAL STORM DRAINGE PIPING
SECTION 1107 SECONDARY (EMERGENCY) ROOF DRAINS
109 TABLE 1106.6 SIZE OF SEMICIRCULAR ROOF GUTTERS
SECTION 1108 COMBINED SANITARY AND STORM SYSTEM
SECTION 1109 VALUES FOR CONTINUOUS FLOW
110 SECTION 1110 CONTROLLED FLOW ROOF DRAIN SYSTEMS
SECTION 1111 SUBSOIL DRAINS
SECTION 1112 BUILDING SUBDRAINS
SECTION 1113 SUMPS AND PUMPING SYSTEMS
112 CHAPTER 12 – SPECIAL PIPING AND STORAGE SYSTEMS
SECTION 1201 GENERAL
SECTION 1202 MEDICAL GASES
SECTION 1203 OXYGEN SYSTEMS
114 CHAPTER 13 – REFERENCED STANDARDS
ANSI
AHRI
ASME
115 ASSE
117 ASTM
119 AWS
AWWA
120 CISPI
CSA
121 ICC
ISEA
NFPA
122 NSF
PDI
UL
124 APPENDIX B – RATES OF RAINFALL FOR VARIOUS CITIES
126 APPENDIX C – GRAY WATER RECYCLING SYSTEMS
SECTION C101 GENERAL
SECTION C102 SYSTEMS FOR FLUSHING WATER CLOSETS AND URINALS
SECTION C103 SUBSURFACE LANDSCAPE IRRIGATION SYSTEMS
128 TABLE C103.8 LOCATION OF GRAY WATER SYSTEM
TABLE C 103.9.1 DESIGN LOADING RATE
TABLE C103.10 DISTRIBUTION PIPE
129 FIGURE 1 GRAY WATER RECYCLING SYSTEM FOR SUBSURFACE LANDSCAPE IRRIGATION
130 FIGURE 2 GRAY WATER RECYCLING SYSTEM FOR FLUSHING WATER CLOSETS AND URINALS
132 APPENDIX D – DEGREE DAY AND DESIGN TEMPERATURES
TABLE D101 DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES
133 TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES
134 TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES
135 TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES
136 TABLE D101—continued DEGREE DAY AND DESIGN TEMPERATURESa FOR CITIES IN THE UNITED STATES
138 APPENDIX E – SIZING OF WATER PIPING SYSTEM
SECTION E101 GENERAL
SECTION E102 INFORMATION REQUIRED
SECTION E103 SELECTION OF PIPE SIZE
142 TABLE E.1
TABLE E.2
143 FIGURE E103.3(1) EXAMPLE-SIZING
144 TABLE E103.3(1) RECOMMENDED TABULAR ARRANGEMENT FOR USE IN SOLVING PIPE SIZING PROBLEMS
145 TABLE E103.3(2) LOAD VALUES ASSIGNED TO FIXTURES
146 TABLE E103.3(3) TABLE FOR ESTIMATING DEMAND
147 TABLE E103.3(3)—continued TABLE FOR ESTIMATING DEMAND
TABLE E103.3(4) LOSS OF PRESSURE THROUGH TAPS AND TEES IN POUNDS PER SQUARE INCH
148 TABLE E103.3(5) ALLOWANCE IN EQUIVALENT LENGTHS OF PIPE FOR FRICTION LOSS IN VALVES AND THREADED FITTINGS (feet)
TABLE E103.3(6) PRESSURE LOSS IN FITTINGS AND VALVES EXPRESSED AS EQUIVALENT LENGTH OF TUBEa (feet)
149 FIGURE E103.3(2) FRICTION LOSS IN SMOOTH PIPEa (TYPE K, ASTM B 88 COPPER TUBING)
150 FIGURE E103.3(3) FRICTION LOSS IN SMOOTH PIPEa (TYPE L, ASTM B 88 COPPER TUBING)
151 FIGURE E103.3(4) FRICTION LOSS IN SMOOTH PIPEa (TYPE M, ASTM B 88 COPPER TUBING)
152 FIGURE E103.3(5) FRICTION LOSS IN FAIRLY SMOOTH PIPEa
153 FIGURE E103.3(6) FRICTION LOSS IN FAIRLY ROUGH PIPEa
154 FIGURE E103.3(7) FRICTION LOSS IN FAIRLY ROUGH PIPEa
155 SECTION E201 SELECTION OF PIPE SIZE
SECTION E202 DETERMINATION OF PIPE VOLUMES
156 TABLE E201.1MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPINGBASED ON WATER SUPPLY FIXTURE UNIT VALUES
157 TABLE E201.1—continued MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPINGBASED ON WATER SUPPLY FIXTURE UNIT VALUES
158 TABLE E202.1 INTERNAL VOLUME OF VARIOUS WATER DISTRIBUTION TUBING
160 APPENDIX F – STRUCTURAL SAFETY
SECTION F101 CUTTING, NOTCHING AND BORING IN WOOD MEMBERS
162 APPENDIX G – VACUUM DRAINAGE SYSTEM
SECTION G101 VACUUM DRAINAGE SYSTEM
164 INDEX
172 ICC-ES PMG
173 VALUABLE TOOLS TO HELP APPLY YOUR NEW CODE
VA VAPC 2009
$43.33