29.130 – Switchgear and controlgear – PDF Standards Store ?u= Wed, 06 Nov 2024 02:11:53 +0000 en-US hourly 1 https://wordpress.org/?v=6.7.1 ?u=/wp-content/uploads/2024/11/cropped-icon-150x150.png 29.130 – Switchgear and controlgear – PDF Standards Store ?u= 32 32 JIS E 2501-2:2010 ?u=/product/publishers/jis/jis-e-2501-22010/ Wed, 06 Nov 2024 02:11:53 +0000 Railway applications - Fixed installations - DC switchgear - Part 2: DC circuit-breakers
Published By Publication Date Number of Pages
JIS 2010-02-05 86
]]>
This Standard specifies requirements for d.c. circuit-breakers which are intended to be used in fixed electrical installations with nominal voltage not exceeding 3 000 V d.c., which supply electrical power to railway vehicles.

NOTE 1 Switchgear assemblies, electromagnetic compatibility (EMC) and dependability are not covered in this Standard, but by other parts of lEC 61992 series or by other standards.

NOTE 2 The International Standard corresponding to this Standard and the symbol of degree of correspondence are as follows:

IEC 61992-2: 2006 Railway applications-Fixed installations-DC switchgear-Part 2: DC circuit-breakers (MOD)

The symbols which denote the degree of correspondence in the contents between the relevant International Standard and JIS are IDT (identical), MOD (modified, and NEQ (not equivalent) according to ISO/ lEC Guide 21-1.

]]>
JIS E 2501-1:2010 ?u=/product/publishers/jis/jis-e-2501-12010/ Wed, 06 Nov 2024 02:11:52 +0000 Railway applications - Fixed installations - DC switchgear Part 1: General
Published By Publication Date Number of Pages
JIS 2010-02-05 47
]]>
This Standard specifies general requirements for d.c. switchgear and controlgear (hereafter referred to as "switchgear") which supply electrical power to railway rolling stocks and are intended to be used in fixed electrical installations with nominal voltage not exceeding 3000 V d.c.

NOTE: The International Standard corresponding to this Standard and the symbol of degree of correspondence are as follows.

IEC 61992-1: 2006 Railway applications-Fixed installations-DC switchgear-Part 1: General (MOD)

The symbols which denote the degree of correspondence (MOD) in the contents between the relevant International Standard and JIS are IDT (identical), MOD (modified) and NEQ (not equivalent) according to ISO/IEC Guide 21-1.

]]>
JIS C 8480:1995 ?u=/product/publishers/jis/jis-c-84801995/ Wed, 06 Nov 2024 02:06:40 +0000 Box-Type Switchgear Assemblies for Low-Voltage Distribution Purpose
Published By Publication Date Number of Pages
JIS 1995-03-01 27
]]>
Box-Type Switchgear Assemblies for Low-Voltage Distribution Purpose
Published By Publication Date Number of Pages
JIS 1995-03-01 27
]]>
JIS C 8369:2020 ?u=/product/publishers/jis/jis-c-83692020/ Wed, 06 Nov 2024 02:06:22 +0000 Photoelectric controls for public lighting
Published By Publication Date Number of Pages
JIS 2020-09-23 37
]]>
This Japanese Industrial Standard specifies the requirements for the photoelectric controls for public lighting (hereafter referred to as a PC switch) of an integral system or a separate system with a rated voltage 100 V or 200 V, intended for use as a single unit in general outdoor places under a.c. single-phase two-wire system.

Herein, general places do not include the following.

a) Places where corrosive gases exist

b) Places where salt damage is anticipated such as seashore

c) Places where it is always high temperature or high humidity

]]>
JIS C 8369:2012 ?u=/product/publishers/jis/jis-c-83692012/ Wed, 06 Nov 2024 02:06:22 +0000 Photoelectric controls for public lighting
Published By Publication Date Number of Pages
JIS 2012-10-22 36
]]>
This Standard specifies photoelectric controls for public lighting (hereafter referred to as "PC switches") of integral system or separate system with a rated voltage 100 V or 200 V intended for use as a single unit in general outdoor places under a.c. singlephase two-wire system.

General places above-mentioned do not include the following.

a) Places where corrosive gases exist

b) Places where salt damage is anticipated such as seashore

c) Places where it is always high temperature or high humidity

]]>
JIS C 8364:2008 ?u=/product/publishers/jis/jis-c-83642008/ Wed, 06 Nov 2024 02:06:17 +0000 Busways
Published By Publication Date Number of Pages
JIS 2008-09-20 33
]]>
Busways
Published By Publication Date Number of Pages
JIS 2008-09-20 33
]]>
JIS C 8328:2020 ?u=/product/publishers/jis/jis-c-83282020/ Wed, 06 Nov 2024 02:06:12 +0000 Low voltage panelboards for household use
Published By Publication Date Number of Pages
JIS 2020-10-21 33
]]>
This Japanese Industrial Standard specifies the requirements for low voltage panelboards for household use (hereafter referred to as panelboards) with the rated current not exceeding 150 A, mainly used as the service entrance equipment in houses etc., in the electric circuit of 100 V AC single-phase two-wire system or 100/200 V AC single-phase three-wire system at 50 Hz or 60 Hz in frequency.

This Standard covers the panelboards used in shops, offices etc. in addition to houses.

This Standard does not cover the panelboards having a special structure such as waterproof type and explosion-proof type.

]]>
JIS C 8328:2003 ?u=/product/publishers/jis/jis-c-83282003/ Wed, 06 Nov 2024 02:06:12 +0000 Low Voltage Panelboards for Household Use
Published By Publication Date Number of Pages
JIS 2003-05-20 26
]]>
Low Voltage Panelboards for Household Use
Published By Publication Date Number of Pages
JIS 2003-05-20 26
]]>
JIS C 8201-2-2:2004 ?u=/product/publishers/jis/jis-c-8201-2-22004/ Wed, 06 Nov 2024 02:05:56 +0000 Low-voltage switchgear and control gear - Part 2-2: Circuit-breakers incorporating residual current protection
Published By Publication Date Number of Pages
JIS 2004-12-20 89
]]>
Low-voltage switchgear and control gear - Part 2-2: Circuit-breakers incorporating residual current protection
Published By Publication Date Number of Pages
JIS 2004-12-20 89
]]>
JIS C 4510:1991 ?u=/product/publishers/jis/jis-c-45101991/ Wed, 06 Nov 2024 02:01:02 +0000 Hook bars for disconnecting switch operation
Published By Publication Date Number of Pages
JIS 1991-10-01 7
]]>
Hook bars for disconnecting switch operation
Published By Publication Date Number of Pages
JIS 1991-10-01 7
]]>