{"id":111850,"date":"2024-10-18T16:17:27","date_gmt":"2024-10-18T16:17:27","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-11073-10441-2013\/"},"modified":"2024-10-24T22:02:51","modified_gmt":"2024-10-24T22:02:51","slug":"ieee-11073-10441-2013","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-11073-10441-2013\/","title":{"rendered":"IEEE 11073 10441 2013"},"content":{"rendered":"

Revision Standard – Active. Within the context of the ISO\/IEEE 11073 family of standards for device communication, this standard establishes a normative definition of communication between personal telehealth cardiovascular fitness and activity monitor devices and compute engines (e.g., cell phones, personal computers, personal health appliances, and set top boxes) in a manner that enables plug-and-play interoperability. It leverages appropriate portions of existing standards including ISO\/IEEE 11073 terminology, information models, application profile standards, and transport standards. It specifies the use of specific term codes, formats, and behaviors in telehealth environments restricting optionality in base frameworks in favor of interoperability. This standard defines a common core of communication functionality for personal telehealth cardiovascular fitness and activity monitor devices.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nIEEE Std 11073-10441-2013 Front Cover <\/td>\n<\/tr>\n
3<\/td>\nTitle Page <\/td>\n<\/tr>\n
6<\/td>\nNotice to users
Laws and regulations
Copyrights
Updating of IEEE documents
Errata <\/td>\n<\/tr>\n
7<\/td>\nPatents <\/td>\n<\/tr>\n
8<\/td>\nParticipants <\/td>\n<\/tr>\n
11<\/td>\nIntroduction <\/td>\n<\/tr>\n
12<\/td>\nContents <\/td>\n<\/tr>\n
15<\/td>\nImportant Notice
1. Overview
1.1 Scope <\/td>\n<\/tr>\n
16<\/td>\n1.2 Purpose
1.3 Context
2. Normative references <\/td>\n<\/tr>\n
17<\/td>\n3. Definitions, acronyms, and abbreviations
3.1 Definitions <\/td>\n<\/tr>\n
18<\/td>\n3.2 Acronyms and abbreviations
4. Introduction to ISO\/IEEE 11073 personal health devices
4.1 General
4.2 Introduction to ISO\/IEEE 11073-20601 modeling constructs
4.2.1 General
4.2.2 Domain information model <\/td>\n<\/tr>\n
19<\/td>\n4.2.3 Service model
4.2.4 Communication model
4.2.5 Implementing the models
4.3 Compliance with other standards
5. Cardiovascular fitness and activity monitor device concepts and modalities <\/td>\n<\/tr>\n
20<\/td>\n5.1 General concepts <\/td>\n<\/tr>\n
21<\/td>\n5.2 3D Acceleration (RT-SA)
5.3 3D Angular acceleration (RT-SA)
5.4 Activity intensity (numeric)
5.5 Activity time (enumeration)
5.6 Age (numeric) <\/td>\n<\/tr>\n
22<\/td>\n5.7 Altitude (numeric)
5.8 Altitude gain (numeric)
5.9 Altitude loss (numeric)
5.10 Ascent time and distance <\/td>\n<\/tr>\n
23<\/td>\n5.11 Body height (numeric)
5.12 Body weight (numeric)
5.13 Breathing rate (numeric)
5.14 Cadence (numeric)
5.15 Calories ingested (numeric)
5.16 Carbohydrate calories ingested (numeric)
5.17 Descent time and distance (numeric)
5.18 Distance (numeric) <\/td>\n<\/tr>\n
24<\/td>\n5.19 Energy expended (numeric)
5.20 Estimated weight loss (numeric)
5.21 Heart rate (numeric)
5.22 Incline (numeric)
5.23 Latitude (numeric)
5.24 Longitude (numeric)
5.25 Maximum recommended heart rate (numeric)
5.26 Proportional integral mode (PIM) (numeric) <\/td>\n<\/tr>\n
25<\/td>\n5.27 Power (numeric)
5.28 Program identifier (enumeration)
5.29 Resistance (numeric)
5.30 Root mean square (RMS) (numeric)
5.31 Session (enumeration)
5.32 Session-subsession-start-indicator (enumeration) <\/td>\n<\/tr>\n
26<\/td>\n5.33 Slopes (numeric)
5.34 Speed (numeric)
5.35 Stride length (numeric)
5.36 Subsession (enumeration)
5.37 Sustained physical activity threshold (numeric)
5.38 Time above threshold (TAT) (numeric) <\/td>\n<\/tr>\n
27<\/td>\n5.39 TAT-threshold (numeric)
6. Cardiovascular fitness and activity monitor domain information model
6.1 Overview
6.2 Class extensions
6.3 Object instance diagram <\/td>\n<\/tr>\n
28<\/td>\n6.4 Types of configuration
6.4.1 General
6.4.2 Standard configuration <\/td>\n<\/tr>\n
29<\/td>\n6.4.3 Extended configuration
6.5 Profiles
6.5.1 General
6.6 Medical device system object
6.6.1 MDS object attributes <\/td>\n<\/tr>\n
30<\/td>\n6.6.2 MDS object methods <\/td>\n<\/tr>\n
31<\/td>\n6.6.3 MDS object events <\/td>\n<\/tr>\n
32<\/td>\n6.6.4 Other MDS services
6.6.4.1 GET service <\/td>\n<\/tr>\n
33<\/td>\n6.6.4.2 SET service
6.7 Numeric objects
6.7.1 General
6.7.1.1 Definitions
6.7.1.2 Dependent attributes
6.7.1.3 Timestamps
6.7.1.4 Source handle reference
6.7.1.5 Methods
6.7.1.6 Events <\/td>\n<\/tr>\n
34<\/td>\n6.7.1.7 Services
6.7.2 Activity intensity <\/td>\n<\/tr>\n
35<\/td>\n6.7.3 Age
6.7.4 Altitude <\/td>\n<\/tr>\n
36<\/td>\n6.7.5 Altitude gain <\/td>\n<\/tr>\n
37<\/td>\n6.7.6 Altitude loss <\/td>\n<\/tr>\n
38<\/td>\n6.7.7 Ascent time and distance <\/td>\n<\/tr>\n
39<\/td>\n6.7.8 Body height <\/td>\n<\/tr>\n
40<\/td>\n6.7.9 Body weight <\/td>\n<\/tr>\n
41<\/td>\n6.7.10 Breathing rate <\/td>\n<\/tr>\n
42<\/td>\n6.7.11 Cadence <\/td>\n<\/tr>\n
43<\/td>\n6.7.12 Calories ingested <\/td>\n<\/tr>\n
44<\/td>\n6.7.13 Carbohydrate calories ingested
Table 16 defines the attributes for the object that represent the carbohydrate calories ingested. This object may be supported by the agent. <\/td>\n<\/tr>\n
45<\/td>\n6.7.14 Descent time and distance <\/td>\n<\/tr>\n
46<\/td>\n6.7.15 Distance <\/td>\n<\/tr>\n
47<\/td>\n6.7.16 Energy expended <\/td>\n<\/tr>\n
48<\/td>\n6.7.17 Estimated weight loss <\/td>\n<\/tr>\n
49<\/td>\n6.7.18 Heart rate
6.7.19 Incline <\/td>\n<\/tr>\n
50<\/td>\n6.7.20 Latitude <\/td>\n<\/tr>\n
51<\/td>\n6.7.21 Longitude <\/td>\n<\/tr>\n
52<\/td>\n6.7.22 Maximum recommended heart rate
6.7.23 PIM <\/td>\n<\/tr>\n
61<\/td>\n6.8 Real-time sample array objects
6.8.1 3D Acceleration X <\/td>\n<\/tr>\n
62<\/td>\n6.8.2 3D Acceleration Y <\/td>\n<\/tr>\n
63<\/td>\n6.8.3 3D Acceleration Z <\/td>\n<\/tr>\n
64<\/td>\n6.8.4 3D Acceleration Z-with-gravity-offset <\/td>\n<\/tr>\n
65<\/td>\n6.8.5 3D Angular acceleration X (pitch)
6.8.6 3D Angular acceleration Y (roll) <\/td>\n<\/tr>\n
66<\/td>\n6.8.7 3D Angular acceleration Z (yaw) <\/td>\n<\/tr>\n
67<\/td>\n6.9 Enumeration objects
6.9.1 General
6.9.1.1 Methods
6.9.1.2 Events
6.9.1.3 Services <\/td>\n<\/tr>\n
68<\/td>\n6.9.2 Activity time <\/td>\n<\/tr>\n
69<\/td>\n6.9.3 Program identifier <\/td>\n<\/tr>\n
70<\/td>\n6.9.4 Session <\/td>\n<\/tr>\n
71<\/td>\n6.9.5 Subsession <\/td>\n<\/tr>\n
72<\/td>\n6.9.6 Session-subsession-start-indicator
6.10 PM-store objects
6.10.1 General <\/td>\n<\/tr>\n
73<\/td>\n6.10.2 Persistent store model <\/td>\n<\/tr>\n
75<\/td>\n6.10.3 PM-store object attributes <\/td>\n<\/tr>\n
76<\/td>\n6.10.5 PM-store object events <\/td>\n<\/tr>\n
77<\/td>\n6.10.6 PM-store object services
6.10.7 PM-segment objects
6.11 Scanner objects
6.11.1 General <\/td>\n<\/tr>\n
78<\/td>\n6.11.2 Periodic configurable scanner attributes <\/td>\n<\/tr>\n
80<\/td>\n6.11.3 Episodic configurable scanner attributes
6.12 Class extension objects <\/td>\n<\/tr>\n
81<\/td>\n6.13 Cardiovascular fitness and activity monitor information model extensibility rules
7. Cardiovascular fitness and activity monitor service model
7.1 General
7.2 Object access services <\/td>\n<\/tr>\n
84<\/td>\n7.3 Object access event report services
8. Cardiovascular fitness and activity monitor communication model
8.1 Overview <\/td>\n<\/tr>\n
85<\/td>\n8.2 Communications characteristics
8.3 Association procedure
8.4 Configuring procedure
8.5 Operating procedure
8.5.1 General
8.5.2 GET cardiovascular fitness and activity monitor MDS attributes
8.5.3 Measurement data transmission of temporarily stored measurements <\/td>\n<\/tr>\n
86<\/td>\n8.6 Time synchronization
9. Test associations
10. Conformance
10.1 Applicability
10.2 Conformance specification <\/td>\n<\/tr>\n
87<\/td>\n10.3 Levels of conformance
10.3.1 General
10.3.2 Conformance level 1: Base conformance
10.3.3 Conformance level 2: Extended nomenclature (ASN.1 and\/or ISO\/IEEE 11073-10101)
10.4 Implementation conformance statements
10.4.1 General format <\/td>\n<\/tr>\n
88<\/td>\n10.4.2 General implementation conformance statement <\/td>\n<\/tr>\n
89<\/td>\n10.4.3 DIM MOC implementation conformance statement
10.4.4 MOC attribute ICS <\/td>\n<\/tr>\n
90<\/td>\n10.4.5 MOC notification implementation conformance statement
10.4.6 MOC nomenclature conformance statement <\/td>\n<\/tr>\n
91<\/td>\n11. Profile: Step counter
11.1 General concepts
11.2 Step counter domain information model
11.2.1 Object instance diagram <\/td>\n<\/tr>\n
92<\/td>\n11.2.2 Types of configuration
11.2.3 Medical device system object
11.2.3.1 Specific MDS object attributes <\/td>\n<\/tr>\n
93<\/td>\n11.2.3.2 MDS object methods
11.2.3.3 MDS object events
11.2.3.4 Other MDS services
11.2.4 Numeric objects (6.7)
11.2.5 Real-time sample array objects
11.2.6 Enumeration objects
11.2.7 PM-store objects
11.2.8 Scanner objects
11.2.9 Communications characteristics <\/td>\n<\/tr>\n
94<\/td>\n12. Profile: Activity monitor
12.1 General concepts
12.2 Physical activity monitor domain information model
12.2.1 Object instance diagram <\/td>\n<\/tr>\n
95<\/td>\n12.2.2 Types of configuration
12.2.3 Medical device system object
12.2.3.1 Specific MDS object attributes <\/td>\n<\/tr>\n
96<\/td>\n12.2.3.2 MDS object methods
12.2.3.3 MDS object events
12.2.3.4 Other MDS services
12.2.4 Numeric objects (6.7)
12.2.5 Real-time sample array objects
12.2.6 Enumeration objects
12.2.7 PM-store objects (6.10)
12.2.8 Scanner objects (6.11) <\/td>\n<\/tr>\n
97<\/td>\n12.2.9 Communications characteristics <\/td>\n<\/tr>\n
99<\/td>\nAnnex A (informative) Bibliography <\/td>\n<\/tr>\n
100<\/td>\nAnnex B (normative) Any additional ASN.1 definitions <\/td>\n<\/tr>\n
101<\/td>\nAnnex C (normative) Allocation of identifiers <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Health Informatic–Personal health device communication Part 10441: Device specialization–Cardiovascular fitness and activity monitor<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
IEEE<\/b><\/a><\/td>\n2013<\/td>\n108<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":111851,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2644],"product_tag":[],"class_list":{"0":"post-111850","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ieee","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/111850","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/111851"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=111850"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=111850"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=111850"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}