{"id":120125,"date":"2024-10-19T04:14:20","date_gmt":"2024-10-19T04:14:20","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/icc-international-mechanical-code-imc-2003\/"},"modified":"2024-10-24T22:48:43","modified_gmt":"2024-10-24T22:48:43","slug":"icc-international-mechanical-code-imc-2003","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/icc\/icc-international-mechanical-code-imc-2003\/","title":{"rendered":"ICC International Mechanical Code (IMC) 2003"},"content":{"rendered":"

Establishes minimum regulations for mechanical systems using prescriptive and performance-related provisions.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
2<\/td>\nPreface <\/td>\n<\/tr>\n
5<\/td>\nOrdinance <\/td>\n<\/tr>\n
7<\/td>\nTable Of Contents <\/td>\n<\/tr>\n
9<\/td>\nChapter 1 – Administration
Section 101 – General
Section 102 – Applicability <\/td>\n<\/tr>\n
10<\/td>\nSection 103 – Department Of Mechanical Inspection
Section 104 – Duties And Powers Of The Code Official
Section 105 – Approval <\/td>\n<\/tr>\n
11<\/td>\nSection 106 – Permits <\/td>\n<\/tr>\n
12<\/td>\nSection 107 – Inspections And Testing <\/td>\n<\/tr>\n
13<\/td>\nSection 108 – Violations <\/td>\n<\/tr>\n
14<\/td>\nSection 109 – Means Of Appeal <\/td>\n<\/tr>\n
17<\/td>\nChapter 2 – Definitions
Section 201 – General
Section 202 – General Definitions <\/td>\n<\/tr>\n
27<\/td>\nChapter 3 – General Regulations
Section 301 – General <\/td>\n<\/tr>\n
28<\/td>\nSection 302 – Protection Of Structure
Section 303 – Equipment And Appliance Location <\/td>\n<\/tr>\n
29<\/td>\nSection 304 – Installation <\/td>\n<\/tr>\n
30<\/td>\nSection 305 – Piping support
Section 306 – Access And Service Space <\/td>\n<\/tr>\n
31<\/td>\nTable 305.4 – Piping Support Spacing <\/td>\n<\/tr>\n
32<\/td>\nSection 307 – Condensate Disposal <\/td>\n<\/tr>\n
33<\/td>\nSection 308 – Clearance Reduction
[B] Section 309 – Temperature Control
[F] Section 310 – Explosion Control
[F] Section 311 – Smoke And Heat Vents
Section 312 – Heating And Cooling Load Calculations <\/td>\n<\/tr>\n
34<\/td>\nTable 308.6 – Clearance Reduction Methods <\/td>\n<\/tr>\n
35<\/td>\nChapter 4 – Ventilation
Section 401 – General
Table 401.6 – Opening Sizes In Louvers, Grilles And Screens Protecting Outdoor Exhaust And Air Intake Openings
[B] Section 402 – Natural Ventilation <\/td>\n<\/tr>\n
36<\/td>\nSection 403 – Mechanical Ventilation
Equation 4-1 <\/td>\n<\/tr>\n
37<\/td>\nTable 403.3 – Required Outdoor Ventilation Air
Table 403.3 – cont. <\/td>\n<\/tr>\n
38<\/td>\nTable 403.3 – cont.
Section 404 – Enclosed Parking Garages
Section 405 – Systems Control
Section 406 – Ventilation Of Uninhabited Spaces <\/td>\n<\/tr>\n
39<\/td>\nChapter 5 – Exhaust Systems
Section 501 – General
Section 502 – Required Systems <\/td>\n<\/tr>\n
40<\/td>\nEquation 5-1 <\/td>\n<\/tr>\n
45<\/td>\nSection 503 – Motors And Fans
Section 504 – Clothes Dryer Exhaust <\/td>\n<\/tr>\n
46<\/td>\nSection 505 – Domestic Kitchen Exhaust Equipment
Section 506 – Commercial Kitchen Hood Ventilation System Ducts And Exhaust Equipment <\/td>\n<\/tr>\n
49<\/td>\nSection 507 – Commercial Kitchen Hoods <\/td>\n<\/tr>\n
50<\/td>\nTable 507.11 – Minimum Distance Between The Lowest Edge Of A Grease Filter And The Cooking Surface Or The Heating Surface <\/td>\n<\/tr>\n
51<\/td>\nSection 508 – Commercial Kitchen Makeup Air <\/td>\n<\/tr>\n
52<\/td>\nSection 509 – Fire Suppression Systems
Section 510 – Hazardous Exhaust Systems <\/td>\n<\/tr>\n
53<\/td>\nTable 510.8 – Minimum Duct Thickness
Table 510.8.2 – Clearance To Combustibles
Section 511 – Dust, Stock And Refuse Conveying Systems <\/td>\n<\/tr>\n
54<\/td>\nSection 512 – Subslab Soil Exhaust Systems
Table 511.2 – Construction, Clearance And Termination Requirements For Single-Wall Metal Chimneys <\/td>\n<\/tr>\n
55<\/td>\nEquation 5-2
Equation 5-3 <\/td>\n<\/tr>\n
56<\/td>\nEquation 5-4
Equation 5-5
Equation 5-6
Equation 5-7
Equation 5-8 <\/td>\n<\/tr>\n
57<\/td>\nEquation 5-9
Equation 5-10 <\/td>\n<\/tr>\n
58<\/td>\nSection 514 – Energy Recovery Ventilation Systems <\/td>\n<\/tr>\n
61<\/td>\nChapter 6 – Duct Systems
Section 601 – General
Section 602 – Plenums <\/td>\n<\/tr>\n
62<\/td>\nSection 603 – Duct Construction And Installation
Table 603.4 – Duct Construction Minimum Sheet Metal Thickness For Single Dwelling Units <\/td>\n<\/tr>\n
63<\/td>\nSection 604 – Insulation <\/td>\n<\/tr>\n
64<\/td>\nSection 605 – Air Filters
Section 606 – Smoke Detection Systems Control <\/td>\n<\/tr>\n
65<\/td>\n[B] Section 607 – Ducts And Air Transfer Openings <\/td>\n<\/tr>\n
66<\/td>\nTable 607.3.1 – Fire Dampering <\/td>\n<\/tr>\n
69<\/td>\nChapter 7 – Combustion Air
Section 701 – General
Section 702 – Inside Air
Section 703 – Outdoor Air <\/td>\n<\/tr>\n
70<\/td>\nSection 704 – Combined Use Of Inside And Outdoor Air (Condition 1)
Section 705 – Combined Use Of Inside And Outdoor Air (Condition 2)
Section 706 – Forced Combustion Air Supply
Section 707 – Direct Connection <\/td>\n<\/tr>\n
71<\/td>\nSection 708 – Combustion Air Ducts
Section 709 – Opening Obstructions
Section 710 – Opening Location And Protection <\/td>\n<\/tr>\n
73<\/td>\nChapter 8 – Chimneys And Vents
Section 801 – General <\/td>\n<\/tr>\n
74<\/td>\nSection 802 – Vents
Table 802.2 – Vent Application <\/td>\n<\/tr>\n
75<\/td>\nSection 803 – Connectors
Table 803.9(1) – Minimum Chimney Connector Thickness For Low-Heat Appliances
Table 803.9(2) – Minimum Chimney Connector Thickness For Medium- And High-Heat Appliances <\/td>\n<\/tr>\n
76<\/td>\nTable 803.10.4 – Chimney Connector Systems And Clearances To Combustible Wall Materials For Domestic Heating Appliances
Table 803.10.6 – Connector Clearances To Combustibles
Section 804 – Direct-Vent, Integral Venst And Mechanical Draft Systems <\/td>\n<\/tr>\n
77<\/td>\nSection 805 – Factory-Built Chimneys <\/td>\n<\/tr>\n
78<\/td>\nSection 806 – Metal Chimneys <\/td>\n<\/tr>\n
79<\/td>\nChapter 9 – Specific Appliances, Fireplaces And Solid Fuel-Burning Equipment
Section 901 – General
Section 902 – Masonry Fireplaces
Section 903 – Factory-Built Fireplaces
Section 904 – Pellet Fuel-Burning Appliances
Section 905 – Fireplace Stoves And Room Heaters
Section 906 – Factory-Built Barbecue Appliances
Section 907 – Incinerators And Crematories
Section 908 – Cooling Towers, Evaporative Condensers And Fluid Coolers <\/td>\n<\/tr>\n
80<\/td>\nSection 909 – Vented Wall Furnaces
Section 910 – Floor Furnaces
Section 911 – Duct Furnaces
Section 912 – Infrared Radiant Heaters
Section 913 – Clothes Dryers <\/td>\n<\/tr>\n
81<\/td>\nSection 914 – Sauna Heaters
Section 915 – Engine And Gas Turbine-Powered Equipment And Appliances
Section 916 – Pool And Spa Heaters
Section 917 – Cooking Appliances
Section 918 – Forced-Air Warm-Air Furnaces <\/td>\n<\/tr>\n
82<\/td>\nSection 919 – Conversion Burners
Section 920 – Unit Heaters
Section 921 – Vented Room Heaters
Section 922 – Kerosene And Oil-Fired Stoves
Section 923 – Small Ceramin Kilns <\/td>\n<\/tr>\n
83<\/td>\nSection 924 – Stationary Fuel Cell Power Plants
Section 925 – Masonry Heaters <\/td>\n<\/tr>\n
85<\/td>\nChapter 10 – Boilers, Water Heaters And Pressure Vessels
Section 1001 – General
Section 1002 – Water Heaters
Section 1003 – Pressure Vessels
Section 1004 – Boilers <\/td>\n<\/tr>\n
86<\/td>\nSection 1005 – Boiler Connections
Section 1006 – Safety And Pressure Relief Valves And Controls
Section 1007 – Boiler Low Water Cutoff
Section 1008 – Steam Blowoff Valve <\/td>\n<\/tr>\n
87<\/td>\nSection 1009 – Hot Water Boiler Expansion Tank
Equation 10-1
Section 1010 – Gauges
Section 1011 – Tests <\/td>\n<\/tr>\n
89<\/td>\nChapter 11 – Refrigeration
Section 1101 – General
Section 1102 – System Requirements <\/td>\n<\/tr>\n
90<\/td>\nSection 1103 – Refigeration System Classification
Section 1104 – System Application Requirements <\/td>\n<\/tr>\n
91<\/td>\n[F] Table 1103.1 – Refrigerant Classification, Amount And TLV-TWA <\/td>\n<\/tr>\n
92<\/td>\n{F} Table 1103.1 – continued <\/td>\n<\/tr>\n
93<\/td>\n[F] Table 1103.1 -continued <\/td>\n<\/tr>\n
94<\/td>\nTable 1104.3.2 – Maximum Permissable Quantities Of Refrigerants <\/td>\n<\/tr>\n
95<\/td>\nSection 1105 – Machinery Room, General Requirements
Equation 11-1
Equation 11-2 <\/td>\n<\/tr>\n
96<\/td>\nSection 1106 – Machinery Room, Special Requirements
Section 1107 – Refrigerant Piping <\/td>\n<\/tr>\n
97<\/td>\nSection 1108 – Field Test
[F] Section 1109 – Periodic Testing <\/td>\n<\/tr>\n
99<\/td>\nChapter 12 – Hydronic Piping
Section 1201 – General
Section 1202 – Material
Table 1202.4 – Hydronic Pipe
Table 1202.4 – continued
Table 1202.5 – Hydronic Pipe Fittings <\/td>\n<\/tr>\n
100<\/td>\nSection 1203 – Joints And Connections <\/td>\n<\/tr>\n
101<\/td>\nSection 1204 – Pipe Insulation
Section 1205 – Valves
Section 1206 – Piping Installation <\/td>\n<\/tr>\n
102<\/td>\nSection 1207 – Transfer Fluid
Section 1208 – Tests
Section 1209 – Embedded Piping <\/td>\n<\/tr>\n
103<\/td>\nChapter 13 – Fuel Oil Piping And Storage
Section 1301 – General
Section 1302 – Material
Table 1302.3 – Fuel Oil Piping
Section 1303 – Joints And Connections <\/td>\n<\/tr>\n
104<\/td>\nSection 1304 – Piping Support
Section 1305 – Fuel Oil System Installation
Section 1306 – Oil Gauging <\/td>\n<\/tr>\n
105<\/td>\nSection 1307 – Fuel Oil Valves
Section 1308 – Testing <\/td>\n<\/tr>\n
107<\/td>\nChapter 14 – Solar Systems
Section 1401 – General
Section 1402 – Installation
Section 1403 – Heat Transfer Fluids <\/td>\n<\/tr>\n
108<\/td>\nSection 1404 – Materials <\/td>\n<\/tr>\n
109<\/td>\nChapter 15 – Referenced Standards <\/td>\n<\/tr>\n
115<\/td>\nAppendix A – Combustion Air Openings And Chimney Connector Pass-Throughs
Figure A-1 – All Air From Inside The Building
Figure A-2 – All Air From Outdoors – Inlet Air From Ventilated Crawl Space And Outlet Air To Ventilated Attic <\/td>\n<\/tr>\n
116<\/td>\nFigure A-3 – All Air From Outdoors Through Ventilated Attic
Figure A-4 – Al lAir From Outdoors Through Horizontal Ducts Or Direct Openings <\/td>\n<\/tr>\n
117<\/td>\nFigure A-5 – Chimney Connector Systems <\/td>\n<\/tr>\n
118<\/td>\nFigure A-5 – continued <\/td>\n<\/tr>\n
119<\/td>\nAppendix B – Recommended Fee Schedule
B101 – Mechanical Work, Other Than Gas Piping Systems
B102 – Fee For Reinspection
B103 – Temporary Operation Inspection Fee
B104 – Self-Contained Units Less Than 2 Tons <\/td>\n<\/tr>\n
121<\/td>\nIndex <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

International Mechanical Code<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ICC<\/b><\/a><\/td>\n2003<\/td>\n126<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":120126,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2670],"product_tag":[],"class_list":{"0":"post-120125","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-icc","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/120125","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/120126"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=120125"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=120125"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=120125"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}