{"id":12236,"date":"2024-10-16T21:00:48","date_gmt":"2024-10-16T21:00:48","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-e2128\/"},"modified":"2024-10-24T11:39:27","modified_gmt":"2024-10-24T11:39:27","slug":"astm-e2128","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-e2128\/","title":{"rendered":"ASTM-E2128"},"content":{"rendered":"<\/p>\n

1.1 This guide describes methods for determining and evaluating causes of water leakage of exterior walls. For this purpose, water penetration is considered leakage, and therefore problematic, if it exceeds the planned resistance or temporary retention and drainage capacity of the wall, is causing or is likely to cause premature deterioration of a building or its contents, or is adversely affecting the performance of other components. A wall is considered a system including its exterior and interior finishes, fenestration, structural components, and components for maintaining the building interior environment.<\/p>\n

1.2 Investigative techniques discussed may be intrusive, disruptive, or destructive. It is the responsibility of the investigator to establish the limitations of use, to anticipate and advise of the destructive nature of some procedures, and to plan for patching and selective reconstruction as necessary.<\/p>\n

1.3 This practice does not purport to address all of the safety concerns, if any, associated with its use. Establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Awareness of safety and familiarity with safe procedures are particularly important for above-ground operations on the exterior of a building and destructive investigative procedures which typically are associated with the work described in this guide.<\/span><\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nScope
Referenced Documents
Terminology
Significance and Use <\/td>\n<\/tr>\n
2<\/td>\nOverview
Review of Project Documents <\/td>\n<\/tr>\n
3<\/td>\nEvaluation of Design Concept
Determination of Service History <\/td>\n<\/tr>\n
5<\/td>\nInspection <\/td>\n<\/tr>\n
7<\/td>\nInvestigative Testing <\/td>\n<\/tr>\n
9<\/td>\nAnalysis
Report Preparation <\/td>\n<\/tr>\n
10<\/td>\nKeywords
A1. BACKGROUND
A1.1 Consequences of Leaks
A1.2 Performance Criteria <\/td>\n<\/tr>\n
11<\/td>\nA1.3 Maintenance
A1.4 Sources of Water
A1.5 Methods of Resisting Leaks <\/td>\n<\/tr>\n
12<\/td>\nA1.6 Sources of Additional Information <\/td>\n<\/tr>\n
13<\/td>\nX1. SEALANTS
X1.1 Scope
X1.2 Referenced Documents
X1.3 Method of Water Penetration Resistance
X1.4 Critical Material Properties
X1.5 Critical Details <\/td>\n<\/tr>\n
14<\/td>\nX1.6 Workmanship
X1.7 Inspection <\/td>\n<\/tr>\n
15<\/td>\nX1.8 Testing
X1.9 Evaluation
X1.10 Sources of Additional Information
X2. MASONRY
X2.1 Scope
X2.2 Referenced Documents <\/td>\n<\/tr>\n
16<\/td>\nX2.3 Method of Water Penetration Resistance
X2.4 Critical Material Properties
X2.5 Critical Details <\/td>\n<\/tr>\n
17<\/td>\nX2.6 Workmanship
X2.7 Inspection <\/td>\n<\/tr>\n
18<\/td>\nX2.8 Testing
X2.9 Evaluation
X2.10 Sources of Additional Information
X3. WINDOWS AND GLASS\/METAL CURTAIN WALLS
X3.1 Scope <\/td>\n<\/tr>\n
19<\/td>\nX3.2 Referenced Documents
X3.3 Method of Water Penetration Resistance
X3.4 Critical Details <\/td>\n<\/tr>\n
20<\/td>\nX3.5 Workmanship
X3.6 Inspection
X3.7 Testing <\/td>\n<\/tr>\n
21<\/td>\nX3.8 Evaluation
X3.9 Sources of Additional Information
X4. EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS)
X4.1 Scope
X4.2 Referenced Documents <\/td>\n<\/tr>\n
22<\/td>\nX4.3 EIFS Types
X4.4 Methods of Water Penetration Resistance
X4.5 Critical Material Properties <\/td>\n<\/tr>\n
23<\/td>\nX4.6 Critical Details
X4.7 Inspection <\/td>\n<\/tr>\n
24<\/td>\nX4.8 Testing
X4.9 Evaluation
X4.10 Sources of Additional Information <\/td>\n<\/tr>\n
25<\/td>\nX5. CEMENT STUCCO AND TILE SYSTEMS
X5.1 Scope
X5.2 Referenced Documents
X5.3 Method of Water Penetration Resistance
X5.4 Critical Material Properties
X5.5 Critical Details <\/td>\n<\/tr>\n
26<\/td>\nX5.6 Workmanship
X5.7 Inspection
X5.8 Testing <\/td>\n<\/tr>\n
27<\/td>\nX5.9 Evaluation
X5.10 Sources of Additional Information
X6. WOOD AND MANUFACTURED WOOD-BASED SIDING SYSTEMS
X6.1 Scope
X6.2 Referenced Documents
X6.3 Methods of Water Penetration Resistance
X6.4 Critical Material Properties <\/td>\n<\/tr>\n
28<\/td>\nX6.5 Critical Details <\/td>\n<\/tr>\n
29<\/td>\nX6.6 Workmanship <\/td>\n<\/tr>\n
30<\/td>\nX6.7 Inspection
X6.8 Testing
X6.9 Evaluation
X6.10 Sources of Additional Information <\/td>\n<\/tr>\n
31<\/td>\nX7. FIBER-CEMENT AND CEMENT-BONDED PARTICLE BOARD SIDING SYSTEMS
X7.1 Scope
X7.2 Referenced Documents
X7.3 Methods of Water Penetration
X7.4 Critical Material Properties <\/td>\n<\/tr>\n
32<\/td>\nX7.5 Critical Details <\/td>\n<\/tr>\n
33<\/td>\nX7.6 Workmanship
X7.7 Inspection <\/td>\n<\/tr>\n
34<\/td>\nX7.8 Testing
X7.9 Evaluation
X7.10 Sources of Additional Information
X8. PRECAST CONCRETE PANELS
X8.1 Scope
X8.2 Referenced Documents
X8.3 Method of Water Penetration\u2014Resistance
X8.4 Critical Material Properties <\/td>\n<\/tr>\n
35<\/td>\nX8.5 Critical Details
X8.6 Inspection
X8.7 Testing
X8.8 Evaluation <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

E2128-01a(2009) Standard Guide for Evaluating Water Leakage of Building Walls<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASTM<\/b><\/a><\/td>\n2009<\/td>\n35<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":12237,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[1236,2637],"product_tag":[],"class_list":{"0":"post-12236","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-91-060-10","7":"product_cat-astm","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/12236","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/12237"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=12236"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=12236"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=12236"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}