{"id":128960,"date":"2024-10-19T06:23:29","date_gmt":"2024-10-19T06:23:29","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/nfpa-318-2015\/"},"modified":"2024-10-24T23:34:00","modified_gmt":"2024-10-24T23:34:00","slug":"nfpa-318-2015","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/nfpa\/nfpa-318-2015\/","title":{"rendered":"NFPA 318 2015"},"content":{"rendered":"
Chemical safety and emergency response demand the 2015 NFPA 318: Standard for the Protection of Semiconductor Fabrication Facilities. The semiconductor industry is continually growing, requiring new safeguards to address evolving hazards. Completely reorganized and up-to-date with the latest coverage of technologies such as photovoltaics, NFPA 318: Standard for the Protection of Semiconductor Fabrication Facilities applies to semiconductor fabrication facilities and comparable R&D areas in which hazardous chemicals are used, stored, and handled — containing a cleanroom or clean zone or both. Chapters address every aspect of safety, from general safety precautions and fire protection to construction, chemical storage and handling, hazardous gas cylinder storage and distribution, bulk silane systems, production and support equipment, emergency control station, and means of egress. This edition adds display panel and photovoltaic production to its scope, along with other major changes. The 2015 NFPA 318 assists all stakeholders involved in fire protection: engineers, AHJs, facility personnel, and contractors. This rewritten, clarified edition provides new definitions, identification of hazardous materials categories, and an introduction to Hazard Production Material (HPM) risk assessment. It also adds numerous new requirements addressing: Hazardous materials Liquid chemical storage and handling Gas storage and handling Production and support equipment Waste treatment Fire protection Get the latest requirements for semiconductor fabrication facilities, in the most user-friendly format, in the 2015 NFPA 318.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | Important Notices and Disclaimers <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Additional Notices and Disclaimers <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | 2.1 General 2.2 NFPA Publications <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | Chapter 1 Administration 1.1 Scope 1.2 Purpose 1.3 Retroactivity 1.4 Equivalency 1.5 Units Chapter 2 Referenced Publications <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | 2.3 Other Publications 2.4 References for Extracts in Mandatory Sections Chapter 3 Definitions 3.1 General 3.2 NFPA Official Definitions <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 3.3 General Definitions <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | Chapter 4 Building Construction and Related Services 4.1 General 4.2 Classification of Occupancy 4.3 Noncombustible Construction Components 4.4 Fire Resistance Rating 4.5 Pass-Throughs in Existing Exit Access Corridors 4.6 Vertical Openings 4.7 Air Supply and Recirculation Systems 4.8 Electrical Classification <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 4.9 Emergency Power System 4.10 Means of Egress Chapter 5 Hazardous Materials \u2014 General Provisions 5.1 Hazardous Chemicals 5.2 HPM Risk Assesment 5.3 Container Delivery <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 5.4 Storage and Handling of Hazardous Chemicals 5.5 Separation of Hazardous Chemicals <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 5.6 Systems, Equipment, and Processes <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 5.7 Supply Piping 5.8 Welding Chapter 6 Liquid Chemical Storage and Handling 6.1 General 6.2 Flammable and Combustible Liquid Delivery Systems <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 6.3 Spill Protection 6.4 Pyrophoric Liquids 6.5 Corrosive Liquids <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 6.6 Toxic and Highly Toxic Materials 6.7 Water Reactive Chemistries 6.8 Oxidizers Chapter 7 Gas Storage and Handling 7.1 General <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 7.2 Corrosive Gases 7.3 Flammable Gases 7.4 Oxidizing Gases 7.5 Pyrophoric Gases 7.6 Silane Systems <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 7.7 Toxic and Highly Toxic Gases 7.8 Unstable Reactive Gases 7.9 Cryogenic Fluids 7.10 Bulk Oxygen Systems 7.11 Gaseous Hydrogen Systems 7.12 Liquefied Hydrogen Systems 7.13 Gas Generation Systems 7.14 Dopant Gas Sources Chapter 8 Production and Support Equipment 8.1 General 8.2 Materials of Construction 8.3 Equipment Safety Systems and Interlocks <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 8.4 Electrical Design 8.5 Process Liquid Heating Equipment 8.6 General Requirements for Tools Using Flammable or Combustible Liquids <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 8.7 Photolithography Tools 8.8 Ion Implanters 8.9 Wet Process and Wet Etch Tools 8.10 CVD and Furnace Tools 8.11 Automated Materials Handling Systems (AMHS) 8.12 Support Equipment 8.13 Production Equipment Fire Protection 8.14 Exposures Chapter 9 Exhaust Systems 9.1 General Exhaust Conditions <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 9.2 Local Hazardous Chemical Exhaust System 9.3 Local Hazardous Chemical Exhaust System Construction 9.4 Hazardous Chemical Exhaust Duct Airflow and Dilution 9.5 Exhaust Ducts 9.6 Hazardous Chemical Exhaust Controls Chapter 10 Waste Treatment 10.1 Waste Recovery and Handling Systems 10.2 Acid Waste Treatment Facility Safeguards <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 10.3 Organic Waste Treatment Facilities 10.4 Waste Liquid Handling 10.5 Effluent Treatment Systems 10.6 Scrubbers 10.7 Vapor Recovery and Vapor Processing Systems <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | Chapter 11 Fire Protection 11.1 Facility-Wide Systems 11.2 Protection of Specific Facility Elements <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | Chapter 12 General Safety Precautions 12.1 Emergency Plan <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 12.2 Emergency Response Team 12.3 Emergency Drills Annex A Explanatory Material <\/td>\n<\/tr>\n | ||||||
34<\/td>\n | Annex B Seismic Protection Annex C Production and Support Equipment <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | Annex D Informational References <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | Index <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" NFPA 318: Standard for the Protection of Semiconductor Fabrication Facilities<\/b><\/p>\n |