{"id":205545,"date":"2024-10-19T13:12:01","date_gmt":"2024-10-19T13:12:01","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-c1310-4\/"},"modified":"2024-10-25T05:52:13","modified_gmt":"2024-10-25T05:52:13","slug":"astm-c1310-4","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-c1310-4\/","title":{"rendered":"ASTM-C1310"},"content":{"rendered":"

ASTM C1310-01-Reapproved2007<\/h3>\n

Withdrawn Standard: Standard Test Method for Determining Radionuclides in Soils by Inductively Coupled Plasma-Mass Spectrometry Using Flow Injection Preconcentration (Withdrawn 2011)<\/h4>\n
\n

ASTM C1310<\/h4>\n

Scope<\/strong><\/p>\n

1.1 This test method covers a procedure for measuring 99<\/sup>Tc and a procedure for measuring 230<\/sup>Th and 234<\/sup>U in soils. It is applicable to background soils and soils that have been contaminated by nuclear processes. It is intended as an alternative to radiochemical methods because it is faster, requires less labor, and produces less waste than many radiochemical methods.<\/p>\n

1.2 Samples are dried, ground, dissolved by fusion, and analyzed by inductively coupled plasma-mass spectrometry (ICP-MS). A sequential flow injection (FI) technique is used to provide lower detection limits than those obtained with direct aspiration into an ICP-MS, and, in the case of 99<\/sup>Tc, provides separation from interferences.<\/p>\n

1.3 The 230<\/sup>Th and 234<\/sup>U procedure also would work for 232<\/sup>Th, 235<\/sup>U, and 238<\/sup>U, but the FI preconcentration usually is not required to measure these isotopes at the concentrations typically found in soils.<\/p>\n

1.4 This test method is guided by quality control procedures derived from U.S. EPA procedures for inorganic analysis reported in SW-846 and the Contract Laboratory Program Statement of Work. The required level of quality control may vary between laboratories and projects. Laboratory statistical quality control procedures are required to ensure that this test method is reliable.<\/p>\n

1.5 Becquerel (Bq) is the acceptable metric unit for radionuclide activity. However, picocurie (pCi) frequently is the unit used to express regulatory limits for radioactivity. The values stated in either of these units shall be regarded as standard. The values stated in each system may not be exact equivalents; therefore, each system must be used independently of the other, without combining values in any way.<\/p>\n

1.6 Refer to Practice C 998 for information on soil sample collection.<\/p>\n

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.<\/i><\/p>\n

Keywords<\/strong><\/p>\n

flow injection; inductively coupled plasma-mass spectrometry; radionuclide determinations; soils; technetium-99; thorium-230; uranium-<\/p>\n

ICS Code<\/strong><\/p>\n

ICS Number Code 13.030.30 (Special wastes)<\/p>\n

DOI:<\/strong> 10.1520\/C1310-01R07<\/p>\n<\/div>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nScope
Referenced Documents
Terminology <\/td>\n<\/tr>\n
2<\/td>\nSummary of Test Method
Significance and Use <\/td>\n<\/tr>\n
3<\/td>\nInterferences
TABLE 1 <\/td>\n<\/tr>\n
4<\/td>\nApparatus
FIG. 1 <\/td>\n<\/tr>\n
5<\/td>\nReagents and Materials
Standards <\/td>\n<\/tr>\n
6<\/td>\nSample Preparation Procedures <\/td>\n<\/tr>\n
7<\/td>\nInstrument Set-Up
Instrumental Analysis Procedure
TABLE 2
TABLE 3 <\/td>\n<\/tr>\n
8<\/td>\nCalculation of Results
FIG. 2
FIG. 3 <\/td>\n<\/tr>\n
9<\/td>\nQuality Control
Precision and Bias
TABLE 4
TABLE 5 <\/td>\n<\/tr>\n
10<\/td>\nTABLE 6
TABLE 7
TABLE 8
TABLE 9 <\/td>\n<\/tr>\n
11<\/td>\nKeywords
TABLE 10
TABLE 11
TABLE 12 <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

C1310-01(2007) Standard Test Method for Determining Radionuclides in Soils by Inductively Coupled Plasma-Mass Spectrometry Using Flow Injection Preconcentration (Withdrawn 2011)<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
ASTM<\/b><\/a><\/td>\n2007<\/td>\n11<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":205552,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[197,2637],"product_tag":[],"class_list":{"0":"post-205545","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-13-030-30","7":"product_cat-astm","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/205545","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/205552"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=205545"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=205545"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=205545"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}