{"id":226624,"date":"2024-10-19T14:43:54","date_gmt":"2024-10-19T14:43:54","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iec-61347-2-142018\/"},"modified":"2024-10-25T08:41:27","modified_gmt":"2024-10-25T08:41:27","slug":"bs-en-iec-61347-2-142018","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iec-61347-2-142018\/","title":{"rendered":"BS EN IEC 61347-2-14:2018"},"content":{"rendered":"

This part of IEC 61347<\/span> <\/span> specifies particular safety requirements for electronic controlgear for use on AC supplies up to 1 000 V at 50 Hz or 60 Hz and\/or DC supplies with operating frequencies deviating from the supply frequency, associated with fluorescent induction lamps as specified in IEC 62532<\/span> <\/span> and IEC 62639<\/span> <\/span>, for high-frequency operation.<\/p>\n

For emergency lighting operation, particular requirements for controlgear operated from a central supply are given in Annex J<\/span>. Performance requirements appropriate to the safe operation of emergency lighting are also contained in Annex J<\/span>.<\/p>\n

Requirements for emergency lighting controlgear operating from non-centralized power supplies are given in IEC 61347\u20112\u20117<\/span> <\/span>.<\/p>\n

\n
\n NOTE\n <\/div>\n

Performance requirements detailed in Annex J<\/span> are those considered to be safety related with respect to reliable emergency operation.<\/p>\n<\/div>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
2<\/td>\nundefined <\/td>\n<\/tr>\n
6<\/td>\nEnglish
CONTENTS <\/td>\n<\/tr>\n
8<\/td>\nFOREWORD <\/td>\n<\/tr>\n
10<\/td>\nINTRODUCTION <\/td>\n<\/tr>\n
11<\/td>\n1 Scope
2 Normative references
3 Terms and definitions <\/td>\n<\/tr>\n
13<\/td>\n4 General requirements
5 General notes on tests
6 Classification
7 Marking
7.1 General
7.2 Mandatory markings <\/td>\n<\/tr>\n
14<\/td>\n7.3 Information to be provided, if applicable
8 Protection against accidental contact with live parts
9 Terminals
10 Provisions for earthing
11 Moisture resistance and insulation
12 Electric strength
13 Thermal endurance test for windings
14 Fault conditions <\/td>\n<\/tr>\n
15<\/td>\n15 Protection of associated components
15.1 Maximum peak voltage under normal operation conditions
15.2 Maximum working voltage under normal and abnormal operating conditions
15.3 Compliance
15.4 Insulation of input terminals of controllable electronic controlgear
Table 1 \u2013 Relation between RMS working voltage and maximum peak voltage <\/td>\n<\/tr>\n
16<\/td>\n16 Abnormal conditions
16.1 Abnormal conditions for DC and\/or AC supplied electronic controlgear
16.2 Additional abnormal conditions for DC only electronic controlgear
17 Construction
18 Creepage distances and clearances
19 Screws, current-carrying parts and connections <\/td>\n<\/tr>\n
17<\/td>\n20 Resistance to heat, fire and tracking
21 Resistance to corrosion <\/td>\n<\/tr>\n
18<\/td>\nAnnexes
Annex A (normative) Test to establish whether a conductive part is a live part which may cause an electric shock <\/td>\n<\/tr>\n
19<\/td>\nAnnex B (normative) Particular requirements for thermally protected lamp controlgear <\/td>\n<\/tr>\n
20<\/td>\nAnnex C (normative) Particular requirements for electronic lamp controlgear with means of protection against overheating <\/td>\n<\/tr>\n
21<\/td>\nAnnex D (normative) Requirements for carrying out the heating tests of thermally protected lamp controlgear <\/td>\n<\/tr>\n
22<\/td>\nAnnex E (normative) Use of constant S other than 4 500 in tw tests <\/td>\n<\/tr>\n
23<\/td>\nAnnex F (normative) Draught-proof enclosure <\/td>\n<\/tr>\n
24<\/td>\nAnnex G (normative) Explanation of the derivation of the values of pulse voltages <\/td>\n<\/tr>\n
25<\/td>\nAnnex H (normative) Tests <\/td>\n<\/tr>\n
26<\/td>\nAnnex I (normative) Additional requirements for built-in magnetic ballast with double or reinforced insulation <\/td>\n<\/tr>\n
27<\/td>\nAnnex J (normative) Particular additional safety requirements for DC and\/or AC supplied electronic controlgear for emergency lighting
J.1 General
J.2 Marking
J.2.1 Mandatory markings
J.2.2 Information to be provided if applicable
J.3 General statement <\/td>\n<\/tr>\n
28<\/td>\nJ.4 Starting conditions
J.5 Operating conditions
J.6 Current
J.7 EMC immunity
J.8 Pulse voltage from central battery systems
J.9 Tests for abnormal conditions
Table J.1 \u2013 Pulse voltages <\/td>\n<\/tr>\n
29<\/td>\nJ.10 Temperature cycling test and endurance test
J.11 Functional safety (EBLF) <\/td>\n<\/tr>\n
30<\/td>\nAnnex K (informative) Conformity testing during manufacture <\/td>\n<\/tr>\n
31<\/td>\nAnnex L (normative) Particular additional requirements for controlgear providing SELV <\/td>\n<\/tr>\n
32<\/td>\nAnnex M (informative) Dielectric strength test voltages for controlgear intended for the use in impulse withstand Category III <\/td>\n<\/tr>\n
33<\/td>\nAnnex N (normative) Requirements for insulation materials used for double or reinforced insulation <\/td>\n<\/tr>\n
34<\/td>\nAnnex O (normative) Additional requirements for built-in electronic controlgear with double or reinforced insulation <\/td>\n<\/tr>\n
35<\/td>\nAnnex P (normative) Creepage distances and clearances and distance through insulation (DTI) for lamp controlgear which are protected against pollution by the use of coating or potting <\/td>\n<\/tr>\n
36<\/td>\nAnnex Q (informative) Example for Up calculation <\/td>\n<\/tr>\n
37<\/td>\nAnnex R (informative) Concept of creepage distances and clearances <\/td>\n<\/tr>\n
38<\/td>\nAnnex S (informative) Examples of controlgear insulation coordination <\/td>\n<\/tr>\n
39<\/td>\nAnnex T (informative) Creepage distances and clearances for controlgear with a higher degree of availability (impulse withstand category III) <\/td>\n<\/tr>\n
40<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Lamp controlgear – articular requirements for DC and\/or AC supplied electronic controlgear for fluorescent induction lamps<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2018<\/td>\n42<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":226628,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[526,2641],"product_tag":[],"class_list":{"0":"post-226624","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-29-140-99","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/226624","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/226628"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=226624"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=226624"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=226624"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}