{"id":228262,"date":"2024-10-19T14:50:30","date_gmt":"2024-10-19T14:50:30","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-60730-2-141997a22008\/"},"modified":"2024-10-25T08:55:23","modified_gmt":"2024-10-25T08:55:23","slug":"bs-en-60730-2-141997a22008","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-60730-2-141997a22008\/","title":{"rendered":"BS EN 60730-2-14:1997+A2:2008"},"content":{"rendered":"

This clause of Part 1 is applicable except as follows:<\/p>\n

1.1<\/b> Replacement:<\/i><\/p>\n

This part of IEC 730 applies to electric actuators for use in, on, or in association with equipment for household and similar use for heating, air-conditioning and ventilation. The equipment may use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof.<\/p>\n

This Part 2 applies to electric actuators using NTC or PTC thermistors, additional requirements for which are contained in Annex J.<\/p>\n

1.1.1<\/b> This Part 2 applies to the inherent safety, to the operating values, operating times and operating sequences where such are associated with equipment safety and to the testing of electric actuators used in, on or in association with, equipment for household and similar use for heating, air-conditioning and ventilation.<\/p>\n

Requirements for specific operating values, operating times and operating sequences may be given in the standards for appliances and equipment.<\/p>\n

Throughout this Part 2 the word \u201cequipment\u201d means \u201cappliance and equipment\u201d.<\/p>\n

Electric actuators for equipment not intended for normal household use, but which nevertheless may be used by the public, such as equipment intended to be used by laymen in shops, in light industry and on farms, are within the scope of this Part 2.<\/p>\n

This Part 2 does not apply to electric actuators designed exclusively for industrial applications.<\/p>\n

EN 60730-2-1 is not applicable to electric actuators.<\/p>\n

This Part 2 does not apply to electric actuators which are mechanically integral with valves.<\/p>\n

See IEC 730-2-8, Particular requirements for electrically operated valves, including mechanical requirements and IEC 730-2-17, Particular requirements for electrically operated gas valves.<\/p>\n

This Part 2 does not apply to electric motors, requirements for which are contained in IEC 34.<\/p>\n

1.1.2<\/b> Requirements for manual switches not integral with an electric actuator are contained in IEC 1058-1.<\/p>\n

1.2<\/b> Replacement:<\/i><\/p>\n

This Part 2 applies to electric actuators with a rated voltage not exceeding 690 V and with a rated current not exceeding 63 A.<\/p>\n

1.3<\/b> Replacement:<\/i><\/p>\n

This Part 2 does not take into account the response value of an automatic action of an electric actuator, if such a response value is dependent upon the method of mounting the electric actuator in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate household equipment or as determined by the manufacturer shall apply.<\/p>\n

1.4<\/b> Replacement:<\/i><\/p>\n

This Part 2 applies also to electric actuators incorporating electronic devices, requirements for which are contained in Annex H.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
1<\/td>\nBRITISH STANDARD <\/td>\n<\/tr>\n
2<\/td>\nNational foreword <\/td>\n<\/tr>\n
4<\/td>\nForeword
Foreword to amendment A1
Foreword to amendment A11
Foreword to amendment A11 <\/td>\n<\/tr>\n
6<\/td>\nContents <\/td>\n<\/tr>\n
7<\/td>\nScope and normative references
Replacement:
Replacement:
Replacement:
Replacement:
Definitions <\/td>\n<\/tr>\n
8<\/td>\nGeneral requirements
General notes on tests
Rating <\/td>\n<\/tr>\n
9<\/td>\nClassification
According to nature of supply
According to their purpose
According to features of automatic action
According to number of automatic cycles (A) of each automatic action <\/td>\n<\/tr>\n
10<\/td>\nInformation
Protection against electric shock
Provision for protective earthing <\/td>\n<\/tr>\n
11<\/td>\nTerminals and terminations
Constructional requirements
Actions
Moisture and dust resistance
Electric strength and insulation resistance
Heating
Not applicable.
Addition:
Replacement:
Replacement: <\/td>\n<\/tr>\n
12<\/td>\nManufacturing deviation and drift
Additional subclauses:
Not applicable.
Environmental stress
Endurance
Manual and mechanical conditions for the tests
Not applicable.
Mechanical strength
Threaded parts and connections
Creepage distances, clearances and distances through insulation
Resistance to heat, fire and tracking
Resistance to corrosion
!Electromagnetic compatibility (EMC) requirements – Emission”
Components
Normal operation
!Electromagnetic compatibility (EMC) requirements – Immunity”
Abnormal operation <\/td>\n<\/tr>\n
13<\/td>\nBlocked output test (temperature)
Not applicable.
Guidance on the use of electronic disconnection
Maximum permitted temperatures for test of blocked output conditions <\/td>\n<\/tr>\n
14<\/td>\nThe annexes of part 1 are applicable, except as follows:
(normative)
(normative)
(normative) <\/td>\n<\/tr>\n
15<\/td>\nBS EN 60730-2-14:1998 <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Automatic electrical controls for household and similar use – Particular requirements for electric actuators<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2010<\/td>\n18<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":228264,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[506,2641],"product_tag":[],"class_list":{"0":"post-228262","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-29-120-01","7":"product_cat-bsi","9":"first","10":"instock","11":"sold-individually","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/228262","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/228264"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=228262"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=228262"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=228262"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}