{"id":233307,"date":"2024-10-19T15:12:20","date_gmt":"2024-10-19T15:12:20","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-pd-iec-tr-61967-1-12010\/"},"modified":"2024-10-25T09:41:33","modified_gmt":"2024-10-25T09:41:33","slug":"bsi-pd-iec-tr-61967-1-12010","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-pd-iec-tr-61967-1-12010\/","title":{"rendered":"BSI PD IEC\/TR 61967-1-1:2010"},"content":{"rendered":"

This part of IEC 61967 provides guidance for exchanging data generated by near-field scan measurements.<\/p>\n

The described exchange format could also be used for near-field scan data generated by simulation software.<\/p>\n

It should be noted that, although it has been developed for near-field scan, its use is not restricted to this application.<\/p>\n

The exchange format can be applied to emission, immunity and impulse immunity near-field scan data in the frequency and time domains.<\/p>\n

The scope of this technical report includes neither the methods used for the measurements or simulations, nor the software and algorithms used for generating the exchange file or for processing or viewing the data contained therein.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
4<\/td>\nEnglish
CONTENTS <\/td>\n<\/tr>\n
6<\/td>\nFOREWORD <\/td>\n<\/tr>\n
8<\/td>\nINTRODUCTION <\/td>\n<\/tr>\n
9<\/td>\n1 Scope
2 Normative references
3 Terms, definitions and abbreviations
3.1 Terms and definitions <\/td>\n<\/tr>\n
10<\/td>\n3.2 Abbreviations
4 General syntax rules and guidelines
4.1 General
4.2 XML requirements <\/td>\n<\/tr>\n
12<\/td>\n4.3 Keyword requirements
4.4 File structure <\/td>\n<\/tr>\n
13<\/td>\nFigures
Figure 1 \u2013 Multiple XML files <\/td>\n<\/tr>\n
14<\/td>\nFigure 2 \u2013 XML files with data files <\/td>\n<\/tr>\n
15<\/td>\n4.5 Values
Figure 3 \u2013 Additional files <\/td>\n<\/tr>\n
17<\/td>\n4.6 Coordinate systems
Tables
Table 1 \u2013 Valid logarithmic units <\/td>\n<\/tr>\n
18<\/td>\nFigure 4 \u2013 Right-hand cartesian coordinate system
Figure 5 \u2013 Left-hand cartesian coordinate system <\/td>\n<\/tr>\n
19<\/td>\nFigure 6 \u2013 Cylindrical coordinate system <\/td>\n<\/tr>\n
20<\/td>\nFigure 7 \u2013 Spherical coordinate system <\/td>\n<\/tr>\n
21<\/td>\nFigure 8 \u2013 Offsets and image positioning (right-hand cartesian)
Figure 9 \u2013 Offsets and image positioning (left-hand cartesian) <\/td>\n<\/tr>\n
22<\/td>\n4.7 Field type and orientation
Figure 10 \u2013 Field orientation \u2013 Right-hand cartesian coordinate system <\/td>\n<\/tr>\n
23<\/td>\nFigure 11 \u2013 Field orientation \u2013 Left-hand cartesian coordinate system
Figure 12 \u2013 Field orientation \u2013 Cylindrical coordinate system <\/td>\n<\/tr>\n
24<\/td>\nFigure 13 \u2013 Field orientation \u2013 Spherical coordinate system <\/td>\n<\/tr>\n
25<\/td>\n4.8 Data syntax
Table 2 \u2013 Relationship between azimuth, zenith angles and field component
Table 3 \u2013 Permitted values for the keyword: Coordinates <\/td>\n<\/tr>\n
28<\/td>\nTable 4 \u2013 Order of measurement points when coordinates are not included <\/td>\n<\/tr>\n
29<\/td>\n4.9 Performance factor <\/td>\n<\/tr>\n
30<\/td>\nTable 5 \u2013 Performance factor linear units
Table 6 \u2013 Performance factor logarithmic units <\/td>\n<\/tr>\n
31<\/td>\n4.10 Images <\/td>\n<\/tr>\n
32<\/td>\nAnnex A (informative) Example files <\/td>\n<\/tr>\n
36<\/td>\nTable A.1 \u2013 Data matrix <\/td>\n<\/tr>\n
38<\/td>\nTable A.2 \u2013 Magnetic field strength <\/td>\n<\/tr>\n
39<\/td>\nTable A.3 \u2013 Magnetic field strength <\/td>\n<\/tr>\n
40<\/td>\nAnnex B (normative) Valid keywords <\/td>\n<\/tr>\n
44<\/td>\nAnnex C (normative) Keyword usage rules
Table C.1 \u2013 File header keywords <\/td>\n<\/tr>\n
45<\/td>\nTable C.2 \u2013 Global keywords
Table C.3 \u2013 Component section keywords <\/td>\n<\/tr>\n
46<\/td>\nTable C.4 \u2013 Setup section keywords <\/td>\n<\/tr>\n
49<\/td>\nTable C.5 \u2013 Probe section keywords <\/td>\n<\/tr>\n
50<\/td>\nTable C.6 \u2013 Data section keywords <\/td>\n<\/tr>\n
53<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Integrated circuits. Measurement of electromagnetic emissions – General conditions and definitions. Near-field scan data exchange format<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2010<\/td>\n56<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":233312,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2641],"product_tag":[],"class_list":{"0":"post-233307","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/233307","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/233312"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=233307"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=233307"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=233307"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}