{"id":242533,"date":"2024-10-19T15:53:59","date_gmt":"2024-10-19T15:53:59","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iec-60684-3-2162019\/"},"modified":"2024-10-25T10:47:07","modified_gmt":"2024-10-25T10:47:07","slug":"bs-en-iec-60684-3-2162019","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iec-60684-3-2162019\/","title":{"rendered":"BS EN IEC 60684-3-216:2019"},"content":{"rendered":"
This part of IEC 60684-3 gives the requirements for four types of heat-shrinkable, flameretarded, limited-fire-hazard sleeving with a thermal endurance rating of 105 \u00b0C as shown below.<\/p>\n
Class A: thin wall shrink ratio 2:1 internal diameter up to 102,0 mm<\/p>\n
Class B: medium wall shrink ratio 2:1 internal diameter up to 60,0 mm<\/p>\n
Class C: thick wall shrink ratio 2:1 internal diameter up to 51,0 mm<\/p>\n
Class D: medium wall shrink ratio 3:1 internal diameter up to 40,0 mm<\/p>\n
These sleevings are normally supplied in the following colours: black, red, green, blue, white, yellow and green\/yellow.<\/p>\n
Sizes or colours other than those listed in this document are available as custom items. These items are considered to comply with this document if they comply with the property requirements listed in Tables 5, 6, 7 and 8, excluding dimensions and mass. Materials which conform to this specification meet established levels of performance.<\/p>\n
However, the selection of a material by a user for a specific application will be based on the actual requirements necessary for adequate performance in that application and not based on this specification alone.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | Annex ZA(normative)Normative references to international publicationswith their corresponding European publications <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | English CONTENTS <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | INTRODUCTION <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 1 Scope 2 Normative references <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 3 Terms and definitions 4 Designation 5 Conditions of test 6 Requirements 7 Sleeving conformance <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | Tables Table 1 \u2013 Dimensional and mass requirements \u2013 Class A Table 2 \u2013 Dimensional and mass requirements \u2013 Class B <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | Table 3 \u2013 Dimensional and mass requirements \u2013 Class C Table 4 \u2013 Dimensional and mass requirements \u2013 Class D <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | Table 5 \u2013 Property requirements (1 of 3) <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | Table 6 \u2013 Requirements for breakdown voltage <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | Table 7 \u2013 Resistance to selected fluids <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | Table 8 \u2013 Additional property requirements <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Flexible insulating sleeving – Specifications for individual types of sleeving. Sheet 216: Heat-shrinkable, flame-retarded, limited-fire-hazard sleeving<\/b><\/p>\n |