{"id":245874,"date":"2024-10-19T16:10:25","date_gmt":"2024-10-19T16:10:25","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/ieee-1653-2-2020\/"},"modified":"2024-10-25T11:11:22","modified_gmt":"2024-10-25T11:11:22","slug":"ieee-1653-2-2020","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/ieee\/ieee-1653-2-2020\/","title":{"rendered":"IEEE 1653.2 2020"},"content":{"rendered":"
Revision Standard – Active. The design, manufacturing, and testing unique to the application of uncontrolled semiconductor power rectifiers for direct current (dc) supplied transportation substation applications up to 1500 V dc nominal output is covered in this standard. The standard is intended to address traction power substation rectifiers that are to be provided as part of a rectifier transformer unit or that are to be provided separately. Application information and extensive definitions of related technical terms are included.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | IEEE Std 1653.2\u2122-2020 Front cover <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | Title page <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | Important Notices and Disclaimers Concerning IEEE Standards Documents <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Participants <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | Contents <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 1.\u2002Overview 1.1\u2002Scope 1.2\u2002Purpose 2.\u2002Normative references <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | 3.\u2002Definitions 3.1\u2002Basic rectifier components and equipment <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 3.2\u2002Appurtenances and auxiliaries <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 3.3\u2002Semiconductor rectifier diode characteristics <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 3.4\u2002Rectifier circuit properties and terminology <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 3.5\u2002Rectifier characteristics <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 3.6\u2002Rectifier unit ratings <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 4.\u2002Symbols and abbreviations 4.1\u2002Rectifier symbols <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 4.2\u2002Rectifier protective device numbers 5.\u2002Rectifier circuits 5.1\u2002General <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 6.\u2002Service conditions 6.1\u2002Usual service conditions 6.2\u2002Unusual service conditions <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 7.\u2002Ratings 7.1\u2002Rating of rectifier units 7.2\u2002Basis of rating 7.3\u2002Standard service ratings <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | 7.4\u2002Operation above rated voltage 8.\u2002Performance characteristics 8.1\u2002Efficiency and losses <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 8.2\u2002Voltage regulation <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | 8.3\u2002Power factor <\/td>\n<\/tr>\n | ||||||
35<\/td>\n | 8.4\u2002Tolerances and unbalance criteria <\/td>\n<\/tr>\n | ||||||
36<\/td>\n | 8.5\u2002Auxiliaries 9.\u2002Nameplates 10.\u2002Interphase transformers 10.1\u2002General <\/td>\n<\/tr>\n | ||||||
37<\/td>\n | 10.2\u2002Specification information 10.3\u2002Submittal information <\/td>\n<\/tr>\n | ||||||
38<\/td>\n | 11.\u2002Test procedures 11.1\u2002Rectifier transformer tests 11.2\u2002Interphase transformer tests 11.3\u2002Rectifier tests <\/td>\n<\/tr>\n | ||||||
41<\/td>\n | 11.4\u2002Rectifier unit tests <\/td>\n<\/tr>\n | ||||||
51<\/td>\n | Annex\u00a0A (informative) Recommended practice and design guide A.1\u2002Harmonics from uncontrolled rectifiers A.2\u2002Rectifier service ratings <\/td>\n<\/tr>\n | ||||||
52<\/td>\n | A.3\u2002Rectifier current unbalance A.4\u2002Rectifier transformer unit circuit configurations <\/td>\n<\/tr>\n | ||||||
53<\/td>\n | A.5\u2002Rectifier protection <\/td>\n<\/tr>\n | ||||||
54<\/td>\n | A.6\u2002Rectifier short circuit current <\/td>\n<\/tr>\n | ||||||
55<\/td>\n | Annex\u00a0B (informative) Commutating reactance transformation constant and power factor specification B.1\u2002Commutating reactance transformation constant B.2\u2002Specification of power factor <\/td>\n<\/tr>\n | ||||||
56<\/td>\n | Annex\u00a0C (informative) Example of current unbalance calculation C.1\u2002Data pertaining to the transformer rectifier unit C.2\u2002Unbalance at 100% load under normal operating conditions <\/td>\n<\/tr>\n | ||||||
57<\/td>\n | C.3\u2002Unbalance under short circuit conditions <\/td>\n<\/tr>\n | ||||||
59<\/td>\n | Annex\u00a0D (informative) Bibliography <\/td>\n<\/tr>\n | ||||||
60<\/td>\n | Back cover <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" IEEE Standard for Uncontrolled Traction Power Rectifiers for Substation Applications up to 1500 V DC Nominal Output<\/b><\/p>\n |