{"id":254730,"date":"2024-10-19T16:50:00","date_gmt":"2024-10-19T16:50:00","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-60255-1512009\/"},"modified":"2024-10-25T12:15:52","modified_gmt":"2024-10-25T12:15:52","slug":"bs-en-60255-1512009","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-60255-1512009\/","title":{"rendered":"BS EN 60255-151:2009"},"content":{"rendered":"
IEC 60255-151:2009 specifies minimum requirements for over\/under current relays. It includes a specification of the protection function, measurement characteristics and time delay characteristics. Defines the influencing factors that affect the accuracy under steady state conditions and performance characteristics during dynamic conditions.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
6<\/td>\n | English CONTENTS <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | 1 Scope and object 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | 4 Specification of the function 4.1 General 4.2 Input Energizing quantities \/ energizing quantities Figures Figure 1 \u2013 Simplified protection function block diagram <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 4.3 Binary input signals 4.4 Functional logic <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | Figure 2 \u2013 Overcurrent independent time characteristic Figure 3 \u2013 Undercurrent independent time characteristic <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | Figure 4 \u2013 Dependent time characteristic <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | Figure 5 \u2013 Definite time reset characteristic <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | Figure 6 \u2013 Definite time reset characteristic (alternative solution with instantaneous reset after relay operation) <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | Figure 7 \u2013 Dependent time reset characteristic <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 4.5 Binary output signals 4.6 Additional influencing functions\/conditions 4.7 Specific characteristics Figure 8 \u2013 Dependent time reset characteristic (alternative solution with instantaneous reset after relay operation) <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 5 Performance specification 5.1 Accuracy related to the characteristic quantity Figure 9 \u2013 Voltage restrained characteristics Figure 10 \u2013 Voltage controlled characteristics <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 5.2 Accuracy related to the operate time 5.3 Accuracy related to the reset time Tables Table 1 \u2013 Multiplier factor on operated time assigned error <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 5.4 Transient performance 5.5 Current transformer requirements Table 2 \u2013 Multiplier factor on reset time assigned error <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 6 Functional test methodology 6.1 General 6.2 Determination of steady state errors related to the characteristic quantity <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 6.3 Determination of steady state errors related to the start and operate time 6.4 Determination of steady state errors related to the reset time Table 3 \u2013 Test points for overcurrent elements Table 4 \u2013 Test points for undercurrent elements <\/td>\n<\/tr>\n | ||||||
26<\/td>\n | 6.5 Determination of transient performance Table 5 \u2013 Test points for overcurrent elements Table 6 \u2013 Test points for undercurrent elements <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | Figure 11 \u2013 Typical test waveform for transient overreach <\/td>\n<\/tr>\n | ||||||
28<\/td>\n | Figure 12 \u2013 Test waveform Table 7 \u2013 Recommended values for the test <\/td>\n<\/tr>\n | ||||||
29<\/td>\n | 7 Documentation requirements 7.1 Type test report 7.2 Other user documentation <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Annex A (normative) Constants for dependent time operating and reset characteristics Table A.1 \u2013 Constants for dependent time operating and reset characteristics <\/td>\n<\/tr>\n | ||||||
32<\/td>\n | Annex B (informative) Reset time determination for relays with trip output only Figure B.1 \u2013 Dependent reset time determination <\/td>\n<\/tr>\n | ||||||
33<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Measuring relays and protection equipment – Functional requirements for over\/under current protection<\/b><\/p>\n |