{"id":255996,"date":"2024-10-19T16:55:31","date_gmt":"2024-10-19T16:55:31","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iec-609002018-tc\/"},"modified":"2024-10-25T12:24:47","modified_gmt":"2024-10-25T12:24:47","slug":"bs-en-iec-609002018-tc","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iec-609002018-tc\/","title":{"rendered":"BS EN IEC 60900:2018 – TC"},"content":{"rendered":"
IEC 60900:2018 is available as \/2 which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. <\/p>\n
IEC 60900:2018 is applicable to insulated, insulating and hybrid hand tools used for working live or close to live parts at nominal voltages up to 1 000 V AC and 1 500 V DC. The products designed and manufactured according to this document contribute to the safety of the users provided they are used by skilled persons, in accordance with safe methods of work and the instructions for use (where appropriate). This document has been prepared in accordance with the requirements of IEC 61477 where applicable. The products covered by this document may have an impact on the environment during some or all stages of its life cycle. These impacts can range from slight to significant, be of short term or long-term duration, and occur at the global, regional or local level. This document does not include requirements and test provisions for the manufacturers of the products, or recommendations to the users of the products for environmental improvement. This fourth edition cancels and replaces the third edition, published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) addition of a third category of tools has been added, namely hybrid hand tools; b) introduction of a new informative Annex A on examples of insulated, insulating and hybrid hand tools. Key words: Live Working, Insulated, Insulating, Hand Tools The contents of the corrigendum of January 2019 have been included in this copy.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
93<\/td>\n | undefined <\/td>\n<\/tr>\n | ||||||
96<\/td>\n | Annex ZA(normative)Normative references to international publicationswith their corresponding European publications <\/td>\n<\/tr>\n | ||||||
98<\/td>\n | English CONTENTS <\/td>\n<\/tr>\n | ||||||
101<\/td>\n | FOREWORD <\/td>\n<\/tr>\n | ||||||
103<\/td>\n | INTRODUCTION <\/td>\n<\/tr>\n | ||||||
104<\/td>\n | 1 Scope 2 Normative references 3 Terms and definitions <\/td>\n<\/tr>\n | ||||||
105<\/td>\n | 4 Requirements 4.1 General requirements 4.1.1 Safety <\/td>\n<\/tr>\n | ||||||
106<\/td>\n | 4.1.2 Performance under load 4.1.3 Multiple-ended hand tools 4.1.4 Marking <\/td>\n<\/tr>\n | ||||||
107<\/td>\n | 4.1.5 Separating of covers 4.1.6 Instructions for correct adjustment and assembly 4.2 Requirements concerning insulating materials 4.2.1 General Figures Figure 1 \u2013 Marking of the electrical working limit adjacent tothe double triangle symbol (IEC 60417-5216:2002-10) <\/td>\n<\/tr>\n | ||||||
108<\/td>\n | 4.2.2 Thermal stability 4.3 Requirement concerning exposed conductive parts of hybrid tools 4.4 Additional requirements 4.4.1 Hand tools capable of being assembled <\/td>\n<\/tr>\n | ||||||
109<\/td>\n | Figure 2 \u2013 Description of the insulating overlapping element and different assembly configurations for hand tools capable of being assembled with square drives Tables Table 1 \u2013 Dimensions and tolerances of the insulating overlapping element <\/td>\n<\/tr>\n | ||||||
110<\/td>\n | 4.4.2 Screwdrivers Figure 3 \u2013 Marking symbol for hand tools capable of being assembled and designed to be interchangeable between different manufacturers (IEC 60417-6168:2012-07) <\/td>\n<\/tr>\n | ||||||
111<\/td>\n | 4.4.3 Spanners \u2013 un-insulated areas Figure 4 \u2013 Illustration of insulation of a typical screwdriver <\/td>\n<\/tr>\n | ||||||
112<\/td>\n | 4.4.4 Adjustable spanners Figure 5 \u2013 Illustration of insulation of typical spanners <\/td>\n<\/tr>\n | ||||||
113<\/td>\n | 4.4.5 Pliers, strippers, cable scissors, cable-cutting hand tools Figure 6 \u2013 Insulated or hybrid adjustable spanner <\/td>\n<\/tr>\n | ||||||
114<\/td>\n | Figure 7 \u2013 Illustration of insulation of typical pliers <\/td>\n<\/tr>\n | ||||||
115<\/td>\n | Figure 8 \u2013 Insulation of pliers Figure 9 \u2013 Insulation of multiple slip joint pliers <\/td>\n<\/tr>\n | ||||||
116<\/td>\n | Figure 10 \u2013 Insulation of pliers with a functional area below the joint <\/td>\n<\/tr>\n | ||||||
117<\/td>\n | 4.4.6 Scissors Figure 11 \u2013 Illustration of insulation of pliers and nippers for electronics <\/td>\n<\/tr>\n | ||||||
118<\/td>\n | 4.4.7 Knives Figure 12 \u2013 Insulation of scissors <\/td>\n<\/tr>\n | ||||||
119<\/td>\n | 4.4.8 Tweezers Figure 13 \u2013 Insulation of knives <\/td>\n<\/tr>\n | ||||||
120<\/td>\n | 5 Tests 5.1 General Figure 14 \u2013 Example of insulation of the handles of tweezers <\/td>\n<\/tr>\n | ||||||
121<\/td>\n | 5.2 Visual check 5.3 Dimensional check 5.4 Impact tests 5.4.1 Type test <\/td>\n<\/tr>\n | ||||||
122<\/td>\n | Figure 15 \u2013 Example of test arrangement for the impact test \u2013 Method A <\/td>\n<\/tr>\n | ||||||
123<\/td>\n | Figure 16 \u2013 Example of test arrangement for the impact test \u2013 Method B <\/td>\n<\/tr>\n | ||||||
124<\/td>\n | 5.4.2 Alternative methods in cases where hand tools have completed the production phase 5.5 Dielectric tests 5.5.1 General requirements <\/td>\n<\/tr>\n | ||||||
125<\/td>\n | 5.5.2 Conditioning (for type test only) 5.5.3 Dielectric testing of insulated and hybrid hand tools <\/td>\n<\/tr>\n | ||||||
126<\/td>\n | Figure 17 \u2013 Dielectric testing arrangement for insulated or hybrid hand tools <\/td>\n<\/tr>\n | ||||||
127<\/td>\n | Figure 18 \u2013 Description of dummies for dielectric tests for hand tools capable of being assembled with square drives Table 2 \u2013 Dimensions and tolerances for dummies to be used for dielectric tests <\/td>\n<\/tr>\n | ||||||
128<\/td>\n | 5.5.4 Dielectric testing of insulating hand tools Figure 19 \u2013 Dielectric testing arrangement for insulating hand tools <\/td>\n<\/tr>\n | ||||||
129<\/td>\n | 5.6 Indentation test (for insulated hand tools) 5.6.1 Type test <\/td>\n<\/tr>\n | ||||||
130<\/td>\n | 5.6.2 Alternative methods in cases where insulated hand tools have completed the production phase 5.7 Test for adhesion of the insulating material coating of insulated hand tools 5.7.1 Conditioning Figure 20 \u2013 Indentation test <\/td>\n<\/tr>\n | ||||||
131<\/td>\n | 5.7.2 Type test <\/td>\n<\/tr>\n | ||||||
132<\/td>\n | Figure 21 \u2013 Principle of the testing device for checking adhesion of the insulating coating on conductive parts of the insulated hand tool \u2013 Test on the working head \u2013 Method A <\/td>\n<\/tr>\n | ||||||
133<\/td>\n | Figure 22 \u2013 Principle of the testing device for checking adhesion of the insulating coating on conductive parts of the insulated hand tools \u2013 Test on the working head \u2013 Method B <\/td>\n<\/tr>\n | ||||||
134<\/td>\n | Figure 23 \u2013 Testing device for checking adhesion of the insulating coating of insulated screwdrivers on conductive parts and the handle <\/td>\n<\/tr>\n | ||||||
136<\/td>\n | 5.7.3 Alternative methods in cases where insulated hand tools have completed the production phase Figure 24 \u2013 Example of mountings for checking stability of adhesion of the insulation of the entire insulated hand tool <\/td>\n<\/tr>\n | ||||||
137<\/td>\n | 5.8 Test of adhesion of exposed conductive parts at the working head of hybrid hand tools 5.8.1 Type test 5.8.2 Alternative methods in cases where hybrid hand tools have completed the production phase 5.9 Mechanical tests 5.9.1 Test of adhesion of insulating covers of conductive adjusting or switching elements <\/td>\n<\/tr>\n | ||||||
138<\/td>\n | 5.9.2 Insulated hand tools 5.9.3 Insulating and hybrid hand tools <\/td>\n<\/tr>\n | ||||||
139<\/td>\n | 5.9.4 Tweezers 5.9.5 Retaining force test for tools capable of being assembled <\/td>\n<\/tr>\n | ||||||
140<\/td>\n | Figure 25 \u2013 Dummies for testing locking systems used with square drives of nominal size 12,5 mm of ISO 1174 <\/td>\n<\/tr>\n | ||||||
141<\/td>\n | Figure 26 \u2013 Dummies for testing locking systems used with square drives of nominal size 10 mm of ISO 1174 <\/td>\n<\/tr>\n | ||||||
142<\/td>\n | 5.10 Durability of marking 5.11 Flame retardancy test 5.11.1 Type test <\/td>\n<\/tr>\n | ||||||
143<\/td>\n | 5.11.2 Alternative methods in cases where hand tools have completed the production phase Figure 27 \u2013 Example of a flame retardancy test arrangement <\/td>\n<\/tr>\n | ||||||
144<\/td>\n | 6 Conformity assessment of hand tools having completed the production phase 7 Modifications <\/td>\n<\/tr>\n | ||||||
145<\/td>\n | Annexes Annex A (informative) Description and examples for insulated, hybrid and insulating hand tools <\/td>\n<\/tr>\n | ||||||
146<\/td>\n | Annex B (informative) Mechanical strength of insulating and hybrid hand tools B.1 Context B.2 General B.3 Insulating and hybrid screwdrivers Table B.1 \u2013 Torque values for insulating and hybrid screwdrivers <\/td>\n<\/tr>\n | ||||||
147<\/td>\n | B.4 Insulating and hybrid spanners and ratchets B.5 Insulating and hybrid T-spanners B.6 Insulating and hybrid pliers and cable shears <\/td>\n<\/tr>\n | ||||||
148<\/td>\n | Annex C (normative) Suitable for live working; double triangle (IEC 60417-5216:200210) <\/td>\n<\/tr>\n | ||||||
149<\/td>\n | Annex D (informative) Recommendation for use and in-service care D.1 General D.2 Storage D.3 Inspection before use D.4 Temperature D.5 Periodic examination and electrical retesting <\/td>\n<\/tr>\n | ||||||
150<\/td>\n | Annex E (normative) General type test procedure Table E.1 \u2013 Sequential order for performing type tests <\/td>\n<\/tr>\n | ||||||
151<\/td>\n | Annex F (normative) Examples of calculation of the total linear length of insulation and acceptable leakage current (see 5.5.3.1.1) <\/td>\n<\/tr>\n | ||||||
152<\/td>\n | Annex G (normative) Classification of defects and tests to be allocated Table G.1 \u2013 Classification of defects and associated requirements and tests <\/td>\n<\/tr>\n | ||||||
153<\/td>\n | Annex H (informative) Rationale for the classification of defects Table H.1 \u2013 Justification for the type of defect <\/td>\n<\/tr>\n | ||||||