{"id":34298,"date":"2024-10-17T04:24:29","date_gmt":"2024-10-17T04:24:29","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/astm-d446-2006\/"},"modified":"2024-10-24T14:45:55","modified_gmt":"2024-10-24T14:45:55","slug":"astm-d446-2006","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/astm\/astm-d446-2006\/","title":{"rendered":"ASTM-D446 2006"},"content":{"rendered":"<\/p>\n
1.1 These specifications cover operating instructions for glass capillary kinematic viscometers of all the types described in detail in Annex A1, Annex A2, and Annex A3 as follows:<\/p>\n
1.2 The calibration of the viscometers is described in Section 6.<\/p>\n
1.3 This standard covers some widely used viscometers suitable for use in accordance with Test Method D 445. Other viscometers of the glass capillary type which are capable of measuring kinematic viscosity within the limits of precision given in Test Method D 445 may be used.<\/p>\n
1.4 The values stated in SI units are to be regarded as the standard. No other units of measurement are included in this standard.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
1<\/td>\n | Scope Referenced Documents Materials and Manufacture Nomenclature for Figures <\/td>\n<\/tr>\n | ||||||
2<\/td>\n | Viscometer Holder and Alignment Calibration of Viscometers <\/td>\n<\/tr>\n | ||||||
3<\/td>\n | Kinematic Viscosity Calculation TABLE 1 <\/td>\n<\/tr>\n | ||||||
4<\/td>\n | Keywords A1. MODIFIED OSTWALD VISCOMETERS A1.1 General A1.2 Operating Instructions <\/td>\n<\/tr>\n | ||||||
5<\/td>\n | FIG. A1.1 <\/td>\n<\/tr>\n | ||||||
6<\/td>\n | FIG. A1.2 <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | FIG. A1.3 <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | FIG. A1.4 <\/td>\n<\/tr>\n | ||||||
9<\/td>\n | FIG. A1.5 <\/td>\n<\/tr>\n | ||||||
10<\/td>\n | FIG. A1.6 <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | FIG. A1.7 TABLE A1.1 <\/td>\n<\/tr>\n | ||||||
12<\/td>\n | A2. SUSPENDED LEVEL VISCOMETERS FOR TRANSPARENT LIQUIDS A2.1 General A2.2 Operating Instructions <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | FIG. A2.1 <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | FIG. A2.2 <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | FIG. A2.3 <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | FIG. A2.4 <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | FIG. A2.5 <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | FIG. A2.6 <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | A3. REVERSE FLOW VISCOMETERS FOR TRANSPARENT AND OPAQUE LIQUIDS A3.1 General FIG. A2.7 <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | A3.2 Operation Instructions FIG. A3.1 <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | FIG. A3.2 <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | FIG. A3.3 <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | FIG. A3.4 <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | REFERENCES <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" D446-06 Standard Specifications and Operating Instructions for Glass Capillary Kinematic Viscometers<\/b><\/p>\n |