{"id":359673,"date":"2024-10-20T01:27:18","date_gmt":"2024-10-20T01:27:18","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bsi-pd-iso-iec-ts-22237-42018\/"},"modified":"2024-10-26T02:10:20","modified_gmt":"2024-10-26T02:10:20","slug":"bsi-pd-iso-iec-ts-22237-42018","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bsi-pd-iso-iec-ts-22237-42018\/","title":{"rendered":"BSI PD ISO\/IEC TS 22237-4:2018"},"content":{"rendered":"
This document addresses environmental control within data centres based upon the criteria and classifications for \u201cavailability\u201d, \u201csecurity\u201d and \u201cenergy efficiency enablement\u201d within ISO\/IEC TS 22237\u20111.<\/p>\n
This document specifies requirements and recommendations for the following:<\/p>\n
temperature control;<\/p>\n<\/li>\n
fluid movement control;<\/p>\n<\/li>\n
relative humidity control;<\/p>\n<\/li>\n
particulate control;<\/p>\n<\/li>\n
vibration;<\/p>\n<\/li>\n
floor layout and equipment locations;<\/p>\n<\/li>\n
energy saving practices;<\/p>\n<\/li>\n
physical security of environmental control systems.<\/p>\n<\/li>\n<\/ol>\n
Issues related to electromagnetic environment can be found in ISO\/IEC TS 22237\u20116.<\/p>\n
PDF Pages<\/th>\n | PDF Title<\/th>\n<\/tr>\n | ||||||
---|---|---|---|---|---|---|---|
2<\/td>\n | National foreword <\/td>\n<\/tr>\n | ||||||
7<\/td>\n | Foreword <\/td>\n<\/tr>\n | ||||||
8<\/td>\n | Introduction <\/td>\n<\/tr>\n | ||||||
11<\/td>\n | 1 Scope 2 Normative references 3 Terms, definitions and abbreviated terms 3.1 Terms and definitions <\/td>\n<\/tr>\n | ||||||
13<\/td>\n | 3.2 Abbreviated terms 4 Conformance 5 Environmental control within data centres 5.1 General 5.1.1 Functional elements <\/td>\n<\/tr>\n | ||||||
14<\/td>\n | 5.1.2 Requirements 5.1.3 Recommendations <\/td>\n<\/tr>\n | ||||||
15<\/td>\n | 5.2 Environmental control of data centre spaces 5.2.1 Building entrance facilities 5.2.2 Personnel entrance(s) 5.2.3 Docking\/loading bay(s) 5.2.4 Generator space(s) including fuel storage 5.2.5 Transformer space(s) <\/td>\n<\/tr>\n | ||||||
16<\/td>\n | 5.2.6 Electrical distribution space(s) 5.2.7 Telecommunication spaces(s) 5.2.8 Main distributor spaces(s) 5.2.9 Computer room space(s) and associated testing space(s) <\/td>\n<\/tr>\n | ||||||
17<\/td>\n | 5.2.10 Electrical space(s) 5.2.11 Mechanical space(s) 5.2.12 Control room space(s) 5.2.13 Office space(s) 5.2.14 Storage and holding space(s) 5.2.15 Accommodation of UPS equipment <\/td>\n<\/tr>\n | ||||||
18<\/td>\n | 6 Availability 6.1 General 6.2 Design options by space 6.2.1 General <\/td>\n<\/tr>\n | ||||||
19<\/td>\n | 6.2.2 Spaces excluded from the availability classification 6.2.3 Main distributor space(s) <\/td>\n<\/tr>\n | ||||||
20<\/td>\n | 6.2.4 Computer room space(s) and associated testing space(s) <\/td>\n<\/tr>\n | ||||||
21<\/td>\n | 6.2.5 UPS space <\/td>\n<\/tr>\n | ||||||
22<\/td>\n | 6.3 Environmental control system capacity planning with respect to expansion 6.4 Environmental control system capacity planning with respect to resilience 7 Physical security 7.1 General 7.2 Access 8 Energy efficiency enablement 8.1 General 8.2 Measurement of temperature 8.2.1 External temperature <\/td>\n<\/tr>\n | ||||||
23<\/td>\n | 8.2.2 Computer room temperature <\/td>\n<\/tr>\n | ||||||
24<\/td>\n | 8.3 Measurement of relative humidity 8.3.1 External relative humidity 8.3.2 Computer room relative humidity <\/td>\n<\/tr>\n | ||||||
25<\/td>\n | 8.4 Measurement of air pressure 8.5 Coolant flow rates 8.6 Heat removal 8.7 Outside air 8.8 Provision of alarms 8.9 Measurement requirements by Granularity Level <\/td>\n<\/tr>\n | ||||||
27<\/td>\n | Annex A (normative) Distribution methodologies for temperature-controlled airin computer room space <\/td>\n<\/tr>\n | ||||||
30<\/td>\n | Annex B (informative) Control system concepts <\/td>\n<\/tr>\n | ||||||
31<\/td>\n | Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" Information technology. Data centre facilities and infrastructures – Environmental control<\/b><\/p>\n |