{"id":371752,"date":"2024-10-20T02:26:10","date_gmt":"2024-10-20T02:26:10","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iec-61800-12021\/"},"modified":"2024-10-26T04:14:06","modified_gmt":"2024-10-26T04:14:06","slug":"bs-en-iec-61800-12021","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iec-61800-12021\/","title":{"rendered":"BS EN IEC 61800-1:2021"},"content":{"rendered":"

This part of IEC 61800 applies to adjustable speed electric DC power drive systems, which include semiconductor power conversion and the means for their control, protection, monitoring, measurement and the DC motors. It applies to adjustable speed electric power drive systems intended to feed DC motors from a BDM\/CDM connected to line-to-line voltages up to and including 1 kV AC 50 Hz or 60 Hz and\/or voltages up to and including 1,5 kV DC input side. NOTE 1 Adjustable speed electric AC power drive systems intended to feed AC motors are covered by IEC 61800-2. NOTE 2 This document can be used as a reference for adjustable speed electric power drive systems, intended to feed DC motors from a BDM\/CDM connected to line-to-line voltages up to and including 1,5 kV AC, 50 Hz or 60 Hz and\/or voltages up to and including 2,25 kV DC input side. Traction applications and electric vehicles are excluded from the scope of this document. This document is intended to define the following aspects of a DC power drive system (PDS): – principal parts of the PDS; – ratings and performance; – specifications for the environment in which the PDS is intended to be installed and operated; – other specifications which might be applicable when specifying a complete PDS. This document provides minimum requirements, which may be used for the development of a specification between customer and manufacturer. Compliance with this document is possible only when each topic of this document is individually specified by the customer developing specifications or by product standard committees developing product standards. For some aspects which are covered by specific PDS product standards in the IEC 61800 series, this document provides a short introduction and reference to detailed requirements in these product standards.<\/p>\n

PDF Catalog<\/h4>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
PDF Pages<\/th>\nPDF Title<\/th>\n<\/tr>\n
2<\/td>\nundefined <\/td>\n<\/tr>\n
4<\/td>\nEuropean foreword
Endorsement notice <\/td>\n<\/tr>\n
5<\/td>\nAnnex ZA (normative) Normative references to international publications with their corresponding European publications <\/td>\n<\/tr>\n
7<\/td>\nEnglish
CONTENTS <\/td>\n<\/tr>\n
13<\/td>\nFOREWORD <\/td>\n<\/tr>\n
15<\/td>\nINTRODUCTION
0.1 General
0.2 Consistency of requirement
0.3 Tool for agreement between customer and manufacturer <\/td>\n<\/tr>\n
17<\/td>\n1 Scope
2 Normative references <\/td>\n<\/tr>\n
19<\/td>\n3 Terms and definitions
3.1 System elements
Tables
Table 1 \u2013 System elements <\/td>\n<\/tr>\n
20<\/td>\nFigures
Figure 1 \u2013 PDS hardware configuration within an installation <\/td>\n<\/tr>\n
21<\/td>\nFigure 2 \u2013 Example of function diagram of a DC power drive system <\/td>\n<\/tr>\n
23<\/td>\nFigure 3 \u2013 BDM\/CDM\/PDS manufacturer\/customer relationship <\/td>\n<\/tr>\n
24<\/td>\n3.2 Converters and circuit elements (see Table 2)
Table 2 \u2013 Converters and circuits elements <\/td>\n<\/tr>\n
25<\/td>\n3.3 Drive system operating characteristics (see Table 3)
Table 3 \u2013 Drive system operating characteristics <\/td>\n<\/tr>\n
27<\/td>\nFigure 4 \u2013 Operating quadrants <\/td>\n<\/tr>\n
28<\/td>\n3.4 Input ratings of BDM\/CDM\/PDS (see Table 4)
Table 4 \u2013 Input ratings of BDM\/CDM\/PDS <\/td>\n<\/tr>\n
32<\/td>\n3.5 Output ratings of BDM\/CDM (see Table 5)
Table 5 \u2013 Output ratings of BDM\/CDM <\/td>\n<\/tr>\n
34<\/td>\n3.6 Motor ratings (see Table 6)
Table 6 \u2013 Motor ratings <\/td>\n<\/tr>\n
37<\/td>\n3.7 Control systems (see Table 7)
Table 7 \u2013 Control system and variables <\/td>\n<\/tr>\n
38<\/td>\n3.8 Tests (see Table 8)
Table 8 \u2013 Type of tests <\/td>\n<\/tr>\n
39<\/td>\n4 Ratings and specifications for the act of installing, commissioning and operation
4.1 General
4.2 BDM\/CDM\/PDS characteristics and topology
4.2.1 General <\/td>\n<\/tr>\n
40<\/td>\n4.2.2 BDM\/CDM\/PDS characteristics
4.2.3 Basic topology for BDM\/CDM\/PDS\u2019s <\/td>\n<\/tr>\n
41<\/td>\nFigure 5 \u2013 Main configurations for line\u2013commutated converters <\/td>\n<\/tr>\n
42<\/td>\nFigure 6 \u2013 Basic configurations of self-commutated converters (choppers) <\/td>\n<\/tr>\n
44<\/td>\n4.3 Ratings
4.3.1 General <\/td>\n<\/tr>\n
45<\/td>\n4.3.2 Input ratings
Figure 7 \u2013 Overview of input and output ratings of the BDM\/CDM\/PDS
Table 9 \u2013 Standard rated voltages as specified in IEC 60038 <\/td>\n<\/tr>\n
46<\/td>\n4.3.3 Output ratings <\/td>\n<\/tr>\n
47<\/td>\nFigure 8 \u2013 Example of operating region of a PDS <\/td>\n<\/tr>\n
48<\/td>\nTable 10 \u2013 Example of reduced maximum continuous load as a function of an overload <\/td>\n<\/tr>\n
49<\/td>\n4.3.4 Operating quadrants
4.3.5 Ratings, properties and functionalities of the BDM\/CDM\/PDS
Figure 9 \u2013 Overload cycle example <\/td>\n<\/tr>\n
50<\/td>\n4.3.6 Special ratings related to BDM\/CDM\/PDS or motor
4.4 Performance
4.4.1 Operational <\/td>\n<\/tr>\n
52<\/td>\nFigure 10 \u2013 Deviation band
Table 11 \u2013 Maximum deviation bands (%) <\/td>\n<\/tr>\n
55<\/td>\nFigure 11 \u2013 Time response following a step change of reference input, no change in operating variables <\/td>\n<\/tr>\n
56<\/td>\nFigure 12 \u2013 Time response following a changein an operating variable \u2013 No reference change <\/td>\n<\/tr>\n
57<\/td>\nFigure 13 \u2013 Time response following a reference change at specified rate <\/td>\n<\/tr>\n
58<\/td>\nFigure 14 \u2013 Frequency response of the control \u2013 Reference value as stimulus <\/td>\n<\/tr>\n
60<\/td>\n4.4.2 Fault supervision and protection
Table 12 \u2013 PDS protection functions <\/td>\n<\/tr>\n
61<\/td>\n4.4.3 Minimum status indication required <\/td>\n<\/tr>\n
62<\/td>\n4.4.4 I\/O devices <\/td>\n<\/tr>\n
64<\/td>\n4.5 General safety
4.6 Functional safety
4.7 EMC <\/td>\n<\/tr>\n
65<\/td>\n4.8 Ecodesign
4.8.1 General
4.8.2 Energy efficiency and power losses
4.8.3 Environmental impact
4.9 Environmental condition for service, transport and storage
4.9.1 General
4.9.2 Operation <\/td>\n<\/tr>\n
66<\/td>\nTable 13 \u2013 Environmental service conditions <\/td>\n<\/tr>\n
67<\/td>\nTable 14 \u2013 Limit of temperature of the cooling medium for indoor equipment
Table 15 \u2013 Definitions of pollution degree <\/td>\n<\/tr>\n
68<\/td>\nTable 16 \u2013 Environmental vibration limits for fixed installation
Table 17 \u2013 Environmental shock limits for fixed installation <\/td>\n<\/tr>\n
70<\/td>\n4.9.3 Storage and transport of equipment
Table 18 \u2013 Storage and transport limits <\/td>\n<\/tr>\n
71<\/td>\n4.9.4 Mechanical conditions
Table 19 \u2013 Transportation vibration limits
Table 20 \u2013 Transportation limits of free fall <\/td>\n<\/tr>\n
72<\/td>\n4.9.5 Specific storage hazards
4.9.6 Environmental service tests (type test) <\/td>\n<\/tr>\n
73<\/td>\n4.10 Types of load duty profiles
4.11 Generic interface and use of profiles for PDS
Table 21 \u2013 Environmental service tests <\/td>\n<\/tr>\n
75<\/td>\n4.12 Voltage on power interface
4.13 Explosive environment
Figure 15 \u2013 Example of relationship of IEC 61800-7 (all parts) to controlsystem software and the BDM\/CDM\/PDS <\/td>\n<\/tr>\n
76<\/td>\n5 Test
5.1 General
5.2 Performance of tests
5.2.1 General conditions
5.2.2 Supply system earthing conditions
5.3 Standard tests for BDM\/CDM\/PDS
5.3.1 General <\/td>\n<\/tr>\n
77<\/td>\nTable 22 \u2013 Tests overview <\/td>\n<\/tr>\n
78<\/td>\n5.3.2 Test for mass produced products
5.3.3 Test for one-off products
5.4 Test specifications
5.4.1 Visual inspections (type test, sample test and routine test) <\/td>\n<\/tr>\n
79<\/td>\n5.4.2 Performance and rating test
Table 23 \u2013 Classification of commutation made by visual observation <\/td>\n<\/tr>\n
81<\/td>\nFigure 16 \u2013 Measuring circuit of PDS <\/td>\n<\/tr>\n
87<\/td>\n5.4.3 General safety
5.4.4 Functional safety
5.4.5 EMC
5.4.6 Energy efficiency and power losses determination
5.4.7 Environmental condition tests <\/td>\n<\/tr>\n
89<\/td>\n5.4.8 Communication profiles
Table 24 \u2013 Shock test <\/td>\n<\/tr>\n
90<\/td>\n5.4.9 Explosive atmosphere environment
6 Information and marking requirements
6.1 General <\/td>\n<\/tr>\n
91<\/td>\n6.2 Marking on product
Table 25 \u2013 Information requirements <\/td>\n<\/tr>\n
92<\/td>\n6.3 Information to be supplied with the PDS or BDM\/CDM
6.4 Information to be supplied or made available
6.5 Safety and warning information
6.5.1 Warning labels
6.5.2 Additional safety considerations of a PDS <\/td>\n<\/tr>\n
94<\/td>\nAnnexes
Annex A (informative) Motor considerations
A.1 General
A.2 Cooling considerations <\/td>\n<\/tr>\n
95<\/td>\nA.3 Waveform ripple considerations
A.3.1 General
A.3.2 Converter topologies
A.3.3 Potentials to earth <\/td>\n<\/tr>\n
96<\/td>\nA.4 Torsional considerations
A.4.1 General
A.4.2 Torsional analysis
A.4.3 Remedies to torsional problems (rare with DC drives)
A.4.4 Torque pulsation
A.5 Operational modes
A.5.1 General <\/td>\n<\/tr>\n
97<\/td>\nA.5.2 Torque\/speed characteristics
Figure A.1 \u2013 Torque and power output of a DC motor <\/td>\n<\/tr>\n
98<\/td>\nA.5.3 Considerations of drive regeneration
A.6 Acoustic noise
A.7 Service life of the motor insulation system <\/td>\n<\/tr>\n
99<\/td>\nA.8 Shaft voltages
A.9 New drive systems <\/td>\n<\/tr>\n
100<\/td>\nAnnex B (informative) Line-side considerations
B.1 General
B.2 AC power source earthing <\/td>\n<\/tr>\n
101<\/td>\nB.3 Introduction to harmonics and inter-harmonics <\/td>\n<\/tr>\n
102<\/td>\nTable B.1 \u2013 Minimum RSC requirements for low voltage systems <\/td>\n<\/tr>\n
103<\/td>\nB.4 Results for typical converters phase control
B.4.1 General
Table B.2 \u2013 Harmonic current \u2013 6-pulse conversion <\/td>\n<\/tr>\n
104<\/td>\nB.4.2 Square wave line current
B.4.3 Trapezoidal line current
B.4.4 Current harmonic with DC current ripple
Figure B.1 \u2013 Thyristor rectifier with a large DC inductance
Figure B.2 \u2013 Square wave line current
Figure B.3 \u2013 Trapezoidal line current <\/td>\n<\/tr>\n
105<\/td>\nFigure B.4 \u2013 Major harmonic components of supply currentconsidering square wave line current with idealized DC ripple <\/td>\n<\/tr>\n
106<\/td>\nB.4.5 Diode rectifiers
Figure B.5 \u2013 Power converter with a diode rectifier on the line-sideand a DC\/DC converter
Figure B.6 \u2013 Input voltage and current waveforms of the diode rectifier <\/td>\n<\/tr>\n
107<\/td>\nB.4.6 Diode rectifiers without DC link inductance
Figure B.7 \u2013 Line-side voltage and current distortion factors of a diode rectifier
Figure B.8 \u2013 Diode rectifier without DC link inductance <\/td>\n<\/tr>\n
108<\/td>\nFigure B.9 \u2013 Input harmonic current (AC and DC)
Figure B.10 \u2013 Input current distortion <\/td>\n<\/tr>\n
109<\/td>\nB.4.7 General
B.5 Example of assessment of harmonic effect of a PDS <\/td>\n<\/tr>\n
110<\/td>\nB.6 Attenuation of emission of harmonics
Figure B.11 \u2013 Example of simple structure
Table B.3 \u2013 Harmonic results for the drive contribution <\/td>\n<\/tr>\n
111<\/td>\nB.7 Commutation notches
Figure B.12 \u2013 3-phase, 6-pulse bridge converter <\/td>\n<\/tr>\n
112<\/td>\nFigure B.13 \u2013 Commutation notches with a 3-phase, 6-pulse bridge converter <\/td>\n<\/tr>\n
113<\/td>\nB.8 Protection against voltage dips and short interruptions
Figure B.14 \u2013 Equivalent circuit for assessment of commutation notch mitigation <\/td>\n<\/tr>\n
115<\/td>\nAnnex C (informative) Auxiliary equipment
C.1 General
C.2 Transformers
C.2.1 General
C.2.2 Voltage
C.2.3 Codes
C.2.4 Provide continuity of service for installations prone to nuisance grounding <\/td>\n<\/tr>\n
116<\/td>\nC.2.5 Line voltage unbalance
C.2.6 Reduction of converter input harmonic currents
C.2.7 Reduction of prospective short-circuit current at converter input
C.2.8 Pulse number
C.3 Reactors <\/td>\n<\/tr>\n
117<\/td>\nC.4 Switchgear <\/td>\n<\/tr>\n
118<\/td>\nAnnex D (informative) Control strategies
D.1 General
D.2 Control configurations
D.2.1 General
Figure D.1 \u2013 Block diagram of feedback control system containing all basic elements <\/td>\n<\/tr>\n
119<\/td>\nD.2.2 Basic structure
D.2.3 Optional facilities
Table D.1 \u2013 Typical control configurations <\/td>\n<\/tr>\n
120<\/td>\nFigure D.2 \u2013 Functional block diagram <\/td>\n<\/tr>\n
121<\/td>\nD.2.4 Digital and analog control
Table D.2 \u2013 Composition of the typical control configurations <\/td>\n<\/tr>\n
122<\/td>\nD.3 Control modes
D.3.1 Operating modes
D.3.2 Loop control
D.3.3 Accuracy and performance <\/td>\n<\/tr>\n
123<\/td>\nD.4 Steady state and transient performance
D.4.1 Time response
D.4.2 Response time
D.4.3 Performances of particular functions
D.4.4 Speed ratio control
Table D.3 \u2013 Drive system control strategies <\/td>\n<\/tr>\n
124<\/td>\nFigure D.3 \u2013 Master\/follower drive system <\/td>\n<\/tr>\n
125<\/td>\nD.5 List of relevant control parameters
D.5.1 BDM\/CDM control parameters
Figure D.4 \u2013 Zero current inversion time <\/td>\n<\/tr>\n
126<\/td>\nD.5.2 Motor parameters
D.5.3 Mechanical parameters
D.5.4 Supply parameters
D.6 Structures
D.6.1 Functional structures <\/td>\n<\/tr>\n
127<\/td>\nFigure D.5 \u2013 Structure of a drive system <\/td>\n<\/tr>\n
128<\/td>\nD.6.2 Hardware structures
D.6.3 Important drive performances issues
D.6.4 Effect of torsional elasticity <\/td>\n<\/tr>\n
129<\/td>\nFigure D.6 \u2013 Mechanical diagram <\/td>\n<\/tr>\n
130<\/td>\nD.6.5 Effects of the backlash
Figure D.7 \u2013 Simple stability criterion <\/td>\n<\/tr>\n
131<\/td>\nAnnex E (informative) Protection
E.1 General
E.2 Equipment availability
E.2.1 General
E.2.2 Equipment protection circuits
E.2.3 Types of equipment alarms and faults <\/td>\n<\/tr>\n
132<\/td>\nE.2.4 Alarm and fault listing
Figure E.1 \u2013 Protection classification <\/td>\n<\/tr>\n
133<\/td>\nE.3 System protection (features and devices)
E.4 Protection of the drive system
E.4.1 Protection included in the BDM\/CDM <\/td>\n<\/tr>\n
134<\/td>\nE.4.2 Specific motor protection
E.4.3 Specific transformer protection <\/td>\n<\/tr>\n
135<\/td>\nAnnex F (informative) Monitoring features
F.1 General
F.2 Technology <\/td>\n<\/tr>\n
136<\/td>\nBibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":"

Adjustable speed electrical power drive systems – General requirements. Rating specifications for low voltage adjustable speed DC power drive systems<\/b><\/p>\n\n\n\n\n
Published By<\/td>\nPublication Date<\/td>\nNumber of Pages<\/td>\n<\/tr>\n
BSI<\/b><\/a><\/td>\n2021<\/td>\n138<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":371761,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2641],"product_tag":[],"class_list":{"0":"post-371752","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/371752","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/371761"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=371752"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=371752"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=371752"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}