{"id":375067,"date":"2024-10-20T02:41:49","date_gmt":"2024-10-20T02:41:49","guid":{"rendered":"https:\/\/pdfstandards.shop\/product\/uncategorized\/bs-en-iec-60068-2-382021\/"},"modified":"2024-10-26T04:42:25","modified_gmt":"2024-10-26T04:42:25","slug":"bs-en-iec-60068-2-382021","status":"publish","type":"product","link":"https:\/\/pdfstandards.shop\/product\/publishers\/bsi\/bs-en-iec-60068-2-382021\/","title":{"rendered":"BS EN IEC 60068-2-38:2021"},"content":{"rendered":"
IEC 60068-2-38:2021 is available as IEC 60068-2-38:2021 RLV<\/span> which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 60068-2-38:2021 specifies a composite test procedure, primarily intended for component type specimens, to determine, in an accelerated manner, the resistance of specimens to the deteriorative effects of high temperature\/humidity and cold conditions. This test standard does not apply to specimens that are energized during the complete test. Specimens can be energized during the constant phases of the tests. Measurements on energized specimens are typically carried out during constant phases of the test unless specified otherwise. This third edition cancels and replaces the second edition, published in 2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: – the figures have been updated; – changes to the wording has been made for clarification purposes.<\/p>\n Environmental testing – Tests. Test Z\/AD: Composite temperature\/humidity cyclic test<\/b><\/p>\nPDF Catalog<\/h4>\n
\n
\n PDF Pages<\/th>\n PDF Title<\/th>\n<\/tr>\n \n 2<\/td>\n undefined <\/td>\n<\/tr>\n \n 5<\/td>\n Annex ZA(normative)Normative references to international publicationswith their corresponding European publications <\/td>\n<\/tr>\n \n 7<\/td>\n English
CONTENTS <\/td>\n<\/tr>\n\n 9<\/td>\n FOREWORD <\/td>\n<\/tr>\n \n 11<\/td>\n 1 Scope
2 Normative references
3 Terms and definitions
4 General
4.1 Description of the test <\/td>\n<\/tr>\n\n 12<\/td>\n 4.2 Application of the test <\/td>\n<\/tr>\n \n 13<\/td>\n 5 Description of test chamber
5.1 General
5.2 Chamber for exposure to moisture
5.3 Chamber for exposure to cold <\/td>\n<\/tr>\n\n 14<\/td>\n 6 Severities
7 Testing procedure
7.1 Preconditioning <\/td>\n<\/tr>\n\n 15<\/td>\n 7.2 Initial measurements
7.3 Conditioning
Figure 1 \u2013 Preconditioning <\/td>\n<\/tr>\n\n 17<\/td>\n Figure 2 \u2013 Exposure to humidity followed by exposure to cold <\/td>\n<\/tr>\n \n 18<\/td>\n 7.4 Test cycle
7.4.1 Description of temperature\/humidity subcycle
Figure 3 \u2013 Exposure to humidity not followed by exposure to cold <\/td>\n<\/tr>\n\n 19<\/td>\n 7.4.2 Description of cold subcycle <\/td>\n<\/tr>\n \n 20<\/td>\n 7.4.3 Description of 24 h cycles with no exposure to cold
7.4.4 Description of final cycle
7.4.5 Intermediate measurements <\/td>\n<\/tr>\n\n 21<\/td>\n Figure 4 \u2013 Test times for intermediate operation of specimen \u2013 Exposure to humidity followed by exposure to cold <\/td>\n<\/tr>\n \n 22<\/td>\n 7.5 Final measurements
7.5.1 Introductory remarks
Figure 5 \u2013 Test times for intermediate operation of specimen \u2013 Exposure to humidity not followed by exposure to cold <\/td>\n<\/tr>\n\n 23<\/td>\n 7.5.2 At high humidity
7.5.3 Immediately upon removal from the chamber
7.5.4 After final drying
8 Information to be given in the relevant specification <\/td>\n<\/tr>\n\n 24<\/td>\n 9 Information to be given in the test report <\/td>\n<\/tr>\n \n 25<\/td>\n Annex A (informative) Supporting documentation for test sequence
A.1 General
A.2 Preconditioning
Table A.1 \u2013 Relative humidity tolerances
Table A.2 \u2013 Temperature tolerances <\/td>\n<\/tr>\n\n 26<\/td>\n A.3 Exposure to humidity followed by exposure to cold
Table A.3 \u2013 Tolerances of relative humidity and temperature during exposure to humidity followed by exposure to cold <\/td>\n<\/tr>\n\n 27<\/td>\n A.4 Exposure to humidity not followed by exposure to cold
Table A.4 \u2013 Tolerances of relative humidity and temperature during exposure to humidity not followed by exposure to cold <\/td>\n<\/tr>\n\n 28<\/td>\n Bibliography <\/td>\n<\/tr>\n<\/table>\n","protected":false},"excerpt":{"rendered":" \n\n
\n Published By<\/td>\n Publication Date<\/td>\n Number of Pages<\/td>\n<\/tr>\n \n BSI<\/b><\/a><\/td>\n 2021<\/td>\n 30<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":375075,"template":"","meta":{"rank_math_lock_modified_date":false,"ep_exclude_from_search":false},"product_cat":[2641],"product_tag":[],"class_list":{"0":"post-375067","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-bsi","8":"first","9":"instock","10":"sold-individually","11":"shipping-taxable","12":"purchasable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product\/375067","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media\/375075"}],"wp:attachment":[{"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/media?parent=375067"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_cat?post=375067"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/pdfstandards.shop\/wp-json\/wp\/v2\/product_tag?post=375067"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}